1. Introduction
This series of ANENG infrared thermometers (models TH202 and TH203) is designed for non-contact measurement of surface temperatures of opaque objects. The device's optical components sense reflected and transmitted energy, focusing it onto a detector to provide quick temperature readings for various high-temperature, toxic, or hard-to-reach objects.
The thermometer comprises an optical system, a photoelectric sensor, a signal amplifier, a signal processing circuit, and a display. The optical system converges infrared energy from the object's surface onto the photoelectric sensor, which converts this energy into an electrical signal. This signal is then processed and displayed as a temperature reading on the LCD.
Model Differences:
- TH203: Features a VA color screen with reverse display and multi-point laser temperature measurement.
- TH202: Features an LCD screen with single-point laser temperature measurement.
2. Safety Information
Important Safety Warning: This product is an industrial thermometer. It is NOT intended for measuring the temperature of humans or animals. Using it for such purposes may lead to inaccurate readings and potential harm.

Image: A warning graphic showing the thermometer should not be used on humans, babies, or animals.
- Do not point the laser directly at eyes or indirectly off reflective surfaces.
- Do not use the device in environments with explosive gas, steam, or dust.
- Keep the device away from electromagnetic fields generated by arc welders or induction heaters.
- Do not immerse the unit in water.
3. Setup
3.1. Battery Installation
- Locate the battery compartment cover at the bottom of the handle.
- Open the cover.
- Insert two AAA batteries, ensuring correct polarity. (Batteries are not included with shipment).
- Close the battery compartment cover securely.

Image: A diagram illustrating the battery slot location and how to install AAA batteries.
3.2. Initial Power On
Once batteries are installed, pull the measuring trigger button to power on the device. The display will light up, indicating it's ready for use.
Video: Product demonstration showing battery installation, power-on, and basic operation.
4. Operating Instructions
4.1. Basic Temperature Measurement
- Point the thermometer at the target object.
- Pull and hold the measuring trigger button. The laser pointer(s) will activate (if enabled) to indicate the measurement area.
- The temperature reading will be displayed on the screen in real-time.
- Release the trigger to hold the last measured value (Data Retention).

Image: The ANENG TH203 thermometer displaying a temperature reading with the laser activated.
4.2. Unit Switching (°C/°F)
Press the '°C/°F' button (often labeled with a temperature icon) to toggle between Celsius and Fahrenheit units.
4.3. Laser Positioning
The TH203 model features multi-point laser positioning for precise targeting. The TH202 model uses a single-point laser. Use the 'Laser Positioning Switch' button (if available on your model) to turn the laser on or off.

Image: A close-up of the thermometer's laser and sensor, illustrating the spot sensing capability.
4.4. Emissivity Adjustment
Emissivity (ε) is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. The default emissivity is 0.95, which is suitable for most organic materials and painted surfaces. For more accurate readings on specific materials, adjust the emissivity using the 'MODE' button and arrow keys.

Image: A table listing recommended emissivity values for common materials like lead, copper, gold, iron, steel, asbestos, gypsum, asphalt, ceramic, wood, charcoal, lacquerware, carbon rubber, soap bubble, water, snow, ice, human skin, graphite, plastic, rubber, concrete, cement, soil, stucco, brick, marble, textile, paper, glass, and tableware.
4.5. High/Low Temperature Alarm
The TH203 model features high and low temperature alarms. You can set specific high and low temperature thresholds. If the measured temperature exceeds the high threshold or falls below the low threshold, a red indicator light will turn on to alert you.
- Press the 'MODE' button to cycle through settings until 'HI' or 'LOW' appears.
- Use the up/down arrow keys to adjust the desired high or low temperature alarm value.
- The red indicator light will activate when the set value is exceeded.

Image: The thermometer displaying a low temperature alarm (-35.8°C) and a high temperature alarm (208°C).
4.6. Data Retention, Auto Power Off, Low Power Prompt
- Data Retention: The last measured value is held on the screen after releasing the trigger.
- Auto Power Off: The device will automatically power off after a period of inactivity to conserve battery life.
- Low Power Prompt: A battery icon will appear on the display when the battery level is low, indicating it's time for replacement.
5. Maintenance
5.1. Cleaning
- Use a soft, damp cloth to clean the device casing. Do not use abrasive cleaners or solvents.
- Carefully clean the optical lens with a soft cloth or cotton swab, avoiding scratches.
5.2. Battery Replacement
When the low power prompt appears, replace the two AAA batteries as described in the 'Battery Installation' section (3.1).
6. Troubleshooting
If you encounter issues with your ANENG Infrared Thermometer, please refer to the following common problems and solutions:
- Device not powering on:
- Check if batteries are installed correctly with the right polarity.
- Replace with fresh AAA batteries. - Inaccurate readings:
- Ensure the target object is within the specified measuring range (-50°C to 600°C / -58°F to 1112°F).
- Verify the emissivity setting is appropriate for the material being measured. (Refer to the emissivity table in section 4.4).
- Ensure there is no smoke or water vapor between the thermometer and the target, as this can affect accuracy. Maintain an angle of about 45°C to 60°C when measuring boiling liquids.
- Ensure the object distance ratio (D:S=12:1) is respected for optimal accuracy. - Display issues (e.g., blank screen, flickering):
- Check battery level and replace if low.
- Ensure the device is not exposed to extreme temperatures or humidity. - Laser not working:
- Check if the laser is enabled via the appropriate button (if applicable to your model).
- Ensure batteries are not low.
For persistent issues or if the product is not operating properly, please contact ANENG customer service. Providing a detailed video of the issue can help expedite assistance.
7. Specifications
| Feature | Specification |
|---|---|
| Brand Name | ANENG |
| Model Number | TH203 Thermometer (also TH202) |
| Theory | Infrared Thermometer |
| Use | Industrial |
| Style | Handheld |
| Measuring Range (°C) | -50°C to 600°C |
| Measuring Range (°F) | -58°F to 1112°F |
| Max Measuring Temperature | 120°C & Above |
| Object Distance Ratio (D:S) | 12:1 |
| Emissivity | Default 0.95 (Adjustable) |
| Multi-point Laser Positioning | Yes (TH203), Single Point (TH202) |
| Display Type | DIGITAL |
| Screen Type | VA color screen (TH203), LCD Screen (TH202) |
| Display Size | 1.9 Inches & Under |
| °C/°F Adjustable | Yes |
| High/Low Temperature Warning | Yes |
| Highest/Lowest Temperature Display | Yes |
| Maximum Value Display | Yes |
| Auto Power Off | Yes |
| Low Power Prompt | Yes |
| Data Retention | Yes |
| Power Type | AAA Battery X2 (not included) |
| Battery Included | No |
| Material | ABS |
| Weight | 106g |
| Certification | CE |
| Is Smart Device | No |
| High-concerned chemical | None |
| Origin | Mainland China |
8. User Tips
- For best accuracy, ensure the target object fills the measurement spot indicated by the laser.
- When measuring highly reflective surfaces, consider applying a matte black paint or tape to the area and measuring that surface for a more accurate reading.
- Always allow the thermometer to stabilize to the ambient temperature of the environment before taking measurements, especially when moving between significantly different temperature zones.
- Keep the lens clean to prevent inaccurate readings. Dust or smudges can interfere with infrared detection.
9. Warranty & Support
For detailed warranty information and after-sales support, please refer to the official user manual PDF or contact ANENG customer service directly. The PDF manual provides comprehensive guidance on product use and troubleshooting.
You can find the official user manual (PDF) at the following link: ANENG TH202/TH203 User Manual (PDF)
After-Sales Questions:
ANENG's professional after-sales team is available to assist you. If you have any questions during the use of the product, please contact customer service for timely solutions.
- About quality issues: In case of quality problems other than 'man-made damage' during use, product replacement or refunds can be provided. Contact customer service to confirm and discuss solutions.
- Replacement or refund request: Provide product quality problem video for damage determination. Solutions may include negotiation, replacement of spare parts, replacement of the whole machine, partial refund, or full refund.
- About the product not operating properly: If there is any problem during use, provide a detailed video of the product not operating normally to ANENG customer service.
- Questions about product use: This brand product is a technical product and requires a certain degree of electrical knowledge. If you encounter operational problems or do not understand how to use the product, contact ANENG customer service for assistance.
- About the product has been artificially damaged: This brand is mostly used to detect electrical and other measurement products. It requires a certain degree of electrical knowledge. Pay attention to the use of certain operating procedures, select the correct measurement method, and avoid dangerous events. If the customer uses the product improperly and the use method is not equal, resulting in damage to the product, it will be judged as man-made damage, which is not within the scope of after-sales service of the product.