1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the HICOMDATA HK-ES3025-8-W 8-Port 2.5G L2-Managed Ethernet Switch PCBA. This product is designed for advanced network communication, offering high-speed connectivity and comprehensive management features for integration into custom systems.

2. Product Specifications
The HK-ES3025-8-W PCBA offers robust performance and features for demanding network environments.

| Feature | Description |
|---|---|
| Model Number | HK-ES3025-8-W |
| Fixed Ports | 8*100M/1G/2.5G RJ45 ports |
| Transmission Rate | 2000 Mbps (Full-Duplex) |
| Switch Capacity | 80Gbps |
| Forwarding Rate | 29.76Mpps |
| MAC Table Size | 16K |
| Package Cache | 12M |
| Forwarding Mode | Store-and-Forward (full wire speed) |
| LED Indicators | PWR (Power), 1-8.Link_indicator, 1G indicator, 2.5G indicator |
| Power Supply | External DC12V 1A |
| Operating Temperature | -20°C ~ +70°C |
| Operating Humidity | 10% ~ 90% (non-coagulation) |
| Physical Dimensions (L x W x H) | 212mm x 108mm x 20mm |
| Net Weight | 0.160kg |
| Functions | LACP, QoS, SNMP, VLAN Support |
| Certifications | CE, FCC, RoHS, WEEE |
For optimal performance, use Cat5 or later UTP cables for 10M/100M/1000M connections (up to 150 meters) and Cat6 or later UTP cables for 2.5G connections (up to 150 meters).
3. Package Contents
The package for the HICOMDATA HK-ES3025-8-W typically includes:
- 1 x HICOMDATA HK-ES3025-8-W L2-Managed Switch PCBA
- (Power adapter and mounting hardware may be sold separately or included depending on the specific kit)

4. Setup Instructions
This section outlines the general steps for setting up your HICOMDATA HK-ES3025-8-W PCBA. Ensure you have all necessary components before proceeding.
4.1. Safety Precautions
- Always handle the PCBA with care to avoid electrostatic discharge (ESD). Use an anti-static wrist strap if available.
- Ensure the power supply matches the specified DC12V 1A requirements. Using an incorrect power supply can damage the device.
- Do not operate the PCBA in environments outside the specified temperature and humidity ranges.
- Ensure proper ventilation if integrating into an enclosure.
4.2. Physical Connection
- Mounting: Securely mount the PCBA within your intended system or enclosure. Ensure it is stable and not subject to excessive vibration.
- Power Connection: Connect a compatible DC12V 1A power adapter to the power input port on the PCBA. Do NOT power on yet.
- Network Connections:
- Connect your network devices (computers, servers, other switches) to the RJ45 ports using appropriate Ethernet cables (Cat5e/Cat6 recommended).
- The ports support 100M, 1G, and 2.5G speeds adaptively.
- Power On: Once all connections are secure, connect the power adapter to an electrical outlet. The PWR LED indicator should illuminate.

5. Operating Instructions
The HK-ES3025-8-W is an L2-Managed switch, meaning it offers advanced configuration options beyond a simple unmanaged switch. Specific management interfaces (e.g., web GUI, CLI, SNMP) would depend on the firmware loaded onto the PCBA. This section provides general operational guidelines.
5.1. LED Indicators
- PWR (Power): Solid green indicates the device is powered on.
- Link/Act Indicators (per port):
- Solid green: A stable network link is established.
- Flashing green: Data activity on the port.
- Off: No link or device is not connected.
- 1G/2.5G Indicators (per port, if present): These LEDs indicate the current link speed. Refer to the specific firmware documentation for exact behavior.
5.2. Basic Network Operation
Upon power-up, the switch will automatically detect connected devices and establish links. It operates in Store-and-Forward mode for efficient data transmission.
5.3. Managed Features (VLAN, QoS, LACP, SNMP)
To configure advanced features such as VLANs, Quality of Service (QoS), Link Aggregation Control Protocol (LACP), or Simple Network Management Protocol (SNMP), you will need to access the switch's management interface. This typically involves:
- Connecting a management device (e.g., a computer) to one of the switch's ports.
- Accessing the switch via its default IP address through a web browser (for web GUI) or a terminal emulator (for CLI).
- Logging in with the default credentials (refer to firmware documentation for these).
- Configuring desired network settings.
Note: Specific instructions for accessing and configuring managed features are dependent on the firmware and management software provided by the manufacturer or integrator. Consult the relevant software documentation for detailed steps.
6. Maintenance
Proper maintenance ensures the longevity and reliable operation of your HICOMDATA HK-ES3025-8-W PCBA.
6.1. Cleaning
- Ensure the device is powered off and disconnected from the power source before cleaning.
- Use a soft, dry cloth to wipe the exterior of the PCBA.
- For dust accumulation, use compressed air to gently clear vents and components.
- Do NOT use liquid cleaners, solvents, or abrasive materials.
6.2. Environmental Considerations
- Keep the PCBA in a well-ventilated area to prevent overheating.
- Avoid exposing the device to direct sunlight, extreme temperatures, or high humidity.
- Protect the device from dust and moisture.
6.3. Firmware Updates
Periodically check the HICOMDATA website or contact your supplier for available firmware updates. Firmware updates can improve performance, add new features, or address security vulnerabilities. Follow the provided instructions carefully when performing firmware updates.
7. Troubleshooting
This section provides solutions to common issues you might encounter with your switch PCBA.
7.1. No Power (PWR LED Off)
- Check if the power adapter is securely connected to both the PCBA and the power outlet.
- Verify that the power outlet is functional.
- Ensure the power adapter meets the DC12V 1A specification.
7.2. No Link (Link/Act LED Off)
- Ensure the Ethernet cable is securely connected to both the switch port and the network device.
- Try a different Ethernet cable to rule out cable failure.
- Verify that the connected network device is powered on and functioning correctly.
- Check the status of the network adapter on the connected device.
7.3. Slow Network Speed
- Ensure you are using appropriate cable types (Cat5e/Cat6 for 1G, Cat6 for 2.5G).
- Check for excessive network traffic or bottlenecks elsewhere in your network.
- Verify that the connected devices support the desired speed (e.g., 2.5G).
- Ensure the switch's ports are operating at the expected speed (check LED indicators or management interface).
7.4. Cannot Access Management Interface
- Verify that your management device is on the same network segment as the switch (or has a route to it).
- Check the switch's IP address and ensure it's not conflicting with another device.
- Ensure you are using the correct default IP address and credentials (refer to firmware documentation).
- Temporarily disable any firewall on your management device that might be blocking access.
8. User Tips
- Cable Quality: For optimal 2.5G performance, always use high-quality Cat6 or higher rated Ethernet cables.
- Heat Management: When integrating the PCBA into a custom enclosure, ensure adequate airflow and heat dissipation, especially given the operating temperature range. The heatsink on the main chip is important for thermal management.
- Firmware Backup: Before performing any major configuration changes or firmware updates, it is good practice to back up the current configuration if the firmware allows.
9. Warranty and Support
HICOMDATA products are designed for reliability and performance. This product comes with standard certifications including CE, FCC, RoHS, and WEEE, ensuring compliance with international standards.

For technical support, warranty claims, or further assistance, please contact your vendor or the official HICOMDATA support channels. Refer to your purchase documentation for specific warranty terms and contact information.
HICOMDATA is committed to providing high-quality products and thoughtful technical services.