1. Introduction
Thank you for choosing the PowMr Pstar Series of Solar Power Controllers. This controller utilizes numerical control technology design and an LCD display for automatic operation. Its Pulse-Width Modulation (PWM) type battery charging mode, combined with advanced control technology, significantly extends battery life.
This controller is designed for independent solar energy systems, automatically managing the charging and discharging processes. The optimized battery charging and discharging process prolongs battery life and enhances system performance. Built-in self-test and electronic protection functions prevent controller damage from installation errors and system failures.
2. Key Features
- Integrated Charge Presets: Adaptive charge logic suitable for most common battery types, including LiFePO4, Gel, and flooded lead-acid.
- Flexible Application: Automatic identification of 12V/24V/36V/48V system voltage.
- Multi-stage Charge Algorithm: Optimized for each recharge cycle and charge maintenance over extended periods.
- Adaptive Boost Charge: Monitors battery response during initial charging to intelligently determine the appropriate boost charge duration, ensuring full recharge and preventing excessive voltage exposure.
- Durable and Safe: Includes protection against overheating (stops charging at 85°C, resumes at 75°C), output short-circuit, over-discharging, and reverse polarity connection (no damage, but controller will not work). Limits maximum charging current to protect battery performance.
- Silent Operation: Designed for natural convection cooling, eliminating the need for a fan or moving parts.
- Lithium Battery Activation: Compatible with Li-ion (LiFePO4) batteries. When set to Lithium battery type, charge cycle settings adjust accordingly. The controller can activate a protected lithium battery using solar panel energy within safe voltage and current ranges. Warning: Do not charge Li-ion batteries if the battery temperature is below 0°C.
3. Important Safety Instructions
WARNING: CAREFULLY READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- Carefully read this manual before installing or operating the controller. Retain this manual for future reference.
- The controller must only be installed and operated by individuals with appropriate knowledge and experience, or under strict supervision.
- Controller Installation and Operation:
- This controller contains no serviceable parts. Do NOT disassemble or attempt to repair it.
- Install the controller in a well-ventilated area with sufficient unobstructed space. Refer to the 'Installation and Connection' section for detailed spacing requirements.
- Mount the controller on a non-flammable surface, ensuring no heat-sensitive items are nearby. The controller may become hot during operation.
- Install the controller indoors, protected from direct sunlight, water, high moisture, and dust. Keep it away from flammable liquids or gases.
- DO NOT install or operate the controller on top of or directly above the battery, or in a sealed compartment with the battery, as batteries can emit explosive gases.
- DO NOT cover the controller or place other items on top of it.
- Battery Installation and Charging:
- Install and charge the battery in a well-ventilated area.
- Ensure no ignition sources are near the battery, as batteries can emit explosive gases.
- Battery acid is corrosive. If contact with skin occurs, rinse immediately with water.
- Do not charge non-rechargeable batteries.
- Do not charge Li-ion batteries if the battery temperature is below 0°C. Never charge a frozen battery.
- Ensure the unit is properly configured for the specific battery type being charged.
- Battery DC Connections:
- Ensure the DC system is fully shut down and isolated before disconnecting existing cabling or making new connections.
- Use flexible, multi-stranded copper cable with sufficient cross-sectional area, along with an appropriate inline fuse or circuit breaker. Refer to the 'Wiring Specification and Breaker Type' section for details.
- NEVER connect the solar panel array to the controller without a battery connected first.
4. Product Overview
The Pstar Series Solar Charge Controller features an intuitive LCD display and function keys for easy monitoring and configuration. The robust design includes a heat sink for efficient cooling.

| No. | Component | No. | Component |
|---|---|---|---|
| 1 | LCD display | 5 | Load port |
| 2 | Function keys | 6 | USB port |
| 3 | PV input port | 7 | Mounting hole (4 x Ø5mm) |
| 4 | Battery port | 8 | Heat sink |
5. Installation and Connection
5.1 Unpacking and Inspection
Before installation, carefully inspect the package for any damage. After unpacking, verify that the package contents are complete and undamaged. The package should include the Pstar Controller and a user manual.
5.2 Preparing for Installation
The Pstar Controller is designed for wall mounting using the flanges on its heatsink backplane.
Mount Location Selection:
Before mounting, consider the following:
- Install the controller in a location with good natural airflow and sufficient unobstructed space.
- Ensure a minimum clearance of 150mm around the top, bottom, and sides of the controller for proper ventilation.
- Mount the controller on a non-flammable substrate. Ensure no heat-sensitive items are in the immediate vicinity.
- Install the controller indoors, protected from environmental conditions like direct sunlight, water, high moisture, and dust. Keep it away from flammable liquids or gases.
- DO NOT install the controller on top of the battery or in a sealed compartment with the battery.
- DO NOT cover the controller or place other items on top of it.

5.3 Required Materials
Ensure you have the following items for installation:
- Pstar Controller (included)
- DC cables for positive and negative connections (3 each for input/output)
- DC breaker (3)
- Screw fittings (Ø 5mm) for mounting (4)
- PV array (1)
- Battery pack (1)
NOTICE:
- For all wiring and circuit breaker specifications, refer to the 'Wiring Specification and Breaker Type' section.
5.4 Wiring Specification and Breaker Type
Determine the maximum PV input current based on the configured system voltage and the technical specifications. The voltage in series must not exceed the maximum PV input open-circuit voltage.
| Model | Max. DC Output Current | Wire Diameter | Circuit Breaker Spec |
|---|---|---|---|
| Pstar-30A | 20A | 10AWG | 2P-20A |
| Pstar-60A | 35A | 8AWG | 2P-35A |
| Pstar-80A | 50A | 6AWG | 2P-50A |
The cables and circuit breakers for the battery should be selected based on the maximum charging current of the connected battery.
5.5 PV Module Selection
When selecting PV modules, consider the following:
- The open circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the controller (100V).
- The open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.
5.6 Wiring Precautions
- Installation and connection work should be performed by a licensed electrician.
- To prevent short circuits and reverse polarity, ensure positive cables connect to positive ports (+) and negative cables to negative ports (-).
- Thin cables and/or loose connections can cause dangerous overheating. Tighten all connections securely and use cables of the correct size as per specifications.
- DO NOT connect an inverter to the load side of the controller. This can cause irreversible damage. If an inverter is needed, refer to the system application diagram below.

5.7 Installation and Connection Step-By-Step
- Mark the mounting spots on the wall using the controller's mounting holes. Drill 4 holes according to these marks.
- Insert expansion rubber screw plugs into the drilled holes.
- Mount the controller vertically with terminals facing down, securing it with 4 M5 screws. It is recommended to 'hang' the unit using the 2 upper screws first, then add the 2 lower screws, and finally tighten all 4 screws.
- Battery Connection: Connect the battery to the controller using appropriate cables.
- PV Connection: Connect the PV array to the controller using appropriate cables.
- DC Output Connection: Connect the load to the controller using appropriate cables.
- Check before starting up: Refer to Figure 3 for wiring details. Once all wires are firmly connected, close the circuit breakers at the battery side, PV module side, and load side in sequence to start the controller.
WARNING: Risk of electric shock!
- Ensure all power is turned off before performing any connections or inspections.
6. Operation Mode
6.1 Charge Algorithm
The battery charging controller features an intelligent 3-stage charge characteristic to optimize battery charging. The Pstar Controller always starts at the Bulk stage when switched on.

- Bulk Charge: The battery is charged at maximum current until the voltage reaches the configured boost charging voltage.
- Boost Charge: The battery is charged at the configured boost charging voltage, with the current gradually decreasing as the battery approaches full charge. The default boost stage duration is adaptive and typically 30 minutes.
- Float Charge: After the boost stage, the controller reduces the battery voltage by lowering the charging current, maintaining the battery at the floating charging voltage to keep it fully charged.
The charging mode parameters can be adjusted via the LCD screen. Refer to the 'Browse and Configuration Parameter Step-By-Step' section for more information.
6.2 Alarm Function
The controller includes an integrated alarm function. For details on protection and fault alarms, refer to the 'Protection' section.
6.3 Operation Interface Introduction
The LCD display provides various system status indicators:
| Icon | Description |
|---|---|
| Indicates the PV input state: daytime state/night state. | |
| Indicates the PV input voltage/PV input current/PV input power. | |
| Indicates the remaining battery capacity. | |
| Indicates current battery voltage/equipment temperature/battery calibration voltage/battery type/boost charging voltage/float charging voltage/low DC cut-off recovery voltage/low DC cut-off voltage. | |
| Indicates DC output mode and DC output operation duration. | |
| Indicates the fault codes. |
Function Keys:
- PV/▲: Switches PV input parameters information / Returns to the previous option.
- BAT/▼: Switches charging information / Enters the next option.
- SET/⚙: Adjusts DC output mode and duration / Confirms and saves settings.
6.4 Browse and Configuration Parameter Step-By-Step
After connecting cables and starting the device, perform initial configuration as follows:
NOTICE:
- The screen backlight automatically turns off after 20 seconds of inactivity to save power. Press any button to reactivate.
- The display automatically returns to the default screen (PV input voltage & current, battery voltage, load enable duration) after 100 seconds of inactivity.
6.4.1 PV Side
Step 1. Checking PV input Information: Press the "PV/▲" key to cycle through PV input voltage, PV input current, and PV input power.
6.4.2 Battery Side
Step 1. Checking Battery Information: Press the "BAT/▼" key to cycle through current battery voltage, equipment temperature, battery calibration voltage, battery type, boost charging voltage, float charging voltage, low DC cut-off recovery voltage, and low DC cut-off voltage.
Step 2. Calibrate Battery Voltage:
- Navigate to the "battery calibration voltage" item. Press and hold "BAT/▼" to enter the calibration setting.
- Use the "PV/▲" or "BAT/▼" keys to adjust the battery voltage parameters to match a multimeter reading.
- Press "SET/⚙" to confirm.
Step 3. Select the Battery Type:
- Navigate to the battery type item. Press and hold "BAT/▼" to enter the battery type adjustment setting.
- Use the "PV/▲" or "BAT/▼" keys to select the appropriate battery type from the list below.
- Press "SET/⚙" to confirm.
| Sequence | Display | Battery Type |
|---|---|---|
| 1 | SEL | Sealed lead acid battery |
| 2 | USE | User-defined |
| 3 | N14 | Ternary lithium battery 14 strings |
| 4 | N13 | Ternary lithium battery 13 strings |
| 5 | N07 | Ternary lithium battery 7 strings |
| 6 | N06 | Ternary lithium battery 6 strings |
| 7 | N03 | Ternary lithium battery 3 strings |
| 8 | L16 | Lithium iron phosphate battery 16 strings |
| 9 | L15 | Lithium iron phosphate battery 15 strings |
| 10 | L08 | Lithium iron phosphate battery 8 strings |
| 11 | L04 | Lithium iron phosphate battery 4 strings |
| 12 | FLd | Vented lead acid battery |
| 13 | GEL | Colloidal lead acid battery |
Step 4. Customize Configured Voltage Parameters:
NOTICE:
- This step is only required when the battery type is set to “USE”.
When the battery type is set to “USE”, configurable parameters are presented in the following order, with each click incrementing by 0.1V.
| Item | Setting Range |
|---|---|
| Nominal system voltage | 12V/24V/36V/48V (optional) |
| Boost charging voltage | 9~17V |
| Float charging voltage | 9~17V |
| Low DC cut-off recovery voltage | 9~17V |
| Low DC cut-off voltage | 8.4~17V |
To adjust parameters:
- Press "BAT/▼" to select the parameter item.
- Press and hold "BAT/▼" to enter the parameter editing mode.
- Use "PV/▲" or "BAT/▼" to adjust the voltage value.
- Press "SET/⚙" to confirm.
CAUTION:
- The parameter ranges above apply to a 12V battery. For 24V/36V/48V batteries, the range values are 2, 3, or 4 times this range, respectively. The LCD will only display the 12V equivalent voltage values.
WARNING:
- The settings must follow this logic: Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage.
6.4.3 Load Side
Step 1. Configure Load Enable Duration:
- Press and hold "SET/⚙" to enter the load mode setting.
- Use "PV/▲" or "BAT/▼" to adjust the load state or load enable duration. Options include:
- 00H: Solar light control mode (loads supply power after dark, stop after dawn).
- 24H (Default): Load is always on. A short press of "SET/⚙" immediately turns off the load output.
- 01H~23H: Adjustable load enable duration (increments of 1 hour).
- Press "SET/⚙" to confirm.
6.5 Key Points of Battery Parameter Settings
Before customizing battery parameters, confirm the following for your connected battery:
- Maximum charging voltage
- Discharging protection voltage
After confirming battery information, set the four key parameters according to this logic:
Max. charging voltage > Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage > Discharge protection voltage
Battery parameters for different types:
| Parameter | FLd | GEL | SEL | USE |
|---|---|---|---|---|
| Boost charging voltage | 14.6V | 14.2V | 14.4V | 14.4V |
| Float charging voltage | 13.8V | 13.8V | 13.8V | 13.8V |
| Low DC cut-off voltage | 11.0V | 11.0V | 11.0V | 11.0V |
| Low DC cut-off recovery voltage | 12.6V | 12.6V | 12.6V | 12.6V |
| Parameter | N03 | N06 | N07 | N13 | N14 |
|---|---|---|---|---|---|
| Boost charging voltage | 12.5V | 25.0V | 29.2V | 54.2V | 58.3V |
| Float charging voltage | 12.2V | 24.4V | 28.5V | 52.9V | 56.9V |
| Low DC cut-off voltage | 8.4V | 16.8V | 19.6V | 36.4V | 39.2V |
| Low DC cut-off recovery voltage | 9.0V | 18.0V | 21.0V | 39.0V | 42.0V |
| Parameter | L04 | L08 | L15 | L16 |
|---|---|---|---|---|
| Boost charging voltage | 14.5V | 29.0V | 54.4V | 58.0V |
| Float charging voltage | 13.8V | 27.6V | 51.8V | 55.2V |
| Low DC cut-off voltage | 11.2V | 22.4V | 42.0V | 44.8V |
| Low DC cut-off recovery voltage | 12.0V | 24.0V | 45.0V | 48.0V |
7. Maintenance
Perform the following inspections and maintenance tasks at least twice a year for optimal performance:
- Ensure the controller is firmly installed in a clean and dry environment.
- Verify that there are no obstructions to airflow around the controller. Clean any dirt or debris from the heat sink.
- Inspect all exposed wires for damaged insulation (due to solarization, friction, wear, dryness, insects, or rodents). Repair or replace damaged wires as necessary.
- Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
- Confirm that all system components are tightly and correctly grounded.
- Check all terminals for corrosion, insulation damage, high temperature, or discolored signs, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. Clean as needed.
WARNING: Risk of electric shock!
- Ensure all power is turned off before performing any maintenance operations.
8. Troubleshooting
In case of a failure, the Pstar Controller display will show an error code to help identify the source of the problem:
| Fault Code | Possible Cause | What to Do |
|---|---|---|
| E65 | Battery undervoltage | Charge the battery and wait until the battery voltage is higher than the low voltage cut-off recovery point. Refer to 'Battery parameters of different types' for details. |
| E63 | Battery overvoltage | Measure if the battery voltage exceeds the rated voltage. Turn off the photovoltaic array air switch. |
| E73 | Charging current is too high | Reduce the number of PV panels connected to the controller to decrease PV input. |
| E60 | Controller over temperature | When the device temperature cools below the recovery temperature, normal charge and discharge control resumes. |
| E81 | Controller overload | Reduce the amount of load on controller connections. |
9. Technical Specifications
| Feature | Pstar-30A | Pstar-60A | Pstar-80A |
|---|---|---|---|
| PV Input | |||
| Max Open Voltage of PV Module | 100V | ||
| PV Operation Voltage Range | >System voltage and ≤100V | ||
| Max. Input Power | |||
| For 12V system | ≤360W | ≤720W | ≤960W |
| For 24V system | ≤720W | ≤1440W | ≤1920W |
| For 36V system | ≤1080W | ≤2160W | ≤2880W |
| For 48V system | ≤1440W | ≤2880W | ≤3840W |
| Charge Mode | |||
| Charging technology | PWM | ||
| Charge Algorithm | 3-Stages | ||
| Self-consumption | ≤20mA | ||
| Nominal System Voltage | 12V/24V/36V/48V | ||
| Rated Charging Current | 30A | 60A | 80A |
| DC Output | |||
| Rated Output Current | 20A | 35A | 50A |
| USB Interface | 5V/2A*2 | ||
| Environment | |||
| Operating Temperature Range | -20°C ~ +55°C | ||
| Humidity Range | ≤90%, Non-condensing | ||
| General Specification | |||
| Protection Class | IP30 | ||
| Dimension | 187*94*49mm | 187*132*60mm | 187*132*60mm |
| Net weight | 0.49kg | 0.77kg | 0.79kg |
10. User Tips
- Lithium Battery Voltage Adjustment: For LiFePO4 batteries, ensure the correct battery type (e.g., L04, L08, L15, L16) is selected in the controller settings. If using a custom battery profile ('USE' type), carefully adjust voltage parameters to match your battery's specific cell-level voltage requirements (e.g., 3.8V per cell for a 12V LiFePO4 setup). Always verify settings with a multimeter.
- PDF User Manual: A comprehensive user manual in PDF format is available for download at https://manuals.plus/m/b1ff40c0ce567b5140fd9128f3583809fda1e5d5f04c6c18de73a60a0dea4314.
11. Warranty and Support
For technical support or warranty inquiries, please contact:
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTDTel/Fax: +86 755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China