Introduction
This manual provides essential information for the safe and efficient operation of your Daxtromn 10.2KW Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.
The Daxtromn AGH-10.2KW-PLUS is a versatile on/off-grid solar hybrid inverter designed to convert DC power from solar panels and batteries into AC power for your home appliances. It features a built-in 160A MPPT charge controller and supports dual PV inputs and dual AC outputs, offering flexible power management solutions.
Key Features
- Pure sine wave solar inverter (on/off Grid capability)
- Output power factor 1.0
- WIFI available for iOS and Android monitoring
- Inverter can run without a battery
- One-key restoration to factory settings
- Built-in Lithium battery automatic activation function
- Built-in 160A MPPT solar charger
- High PV input voltage range (90~450VDC)
- Built-in anti-dusk kit for harsh environments
- Smart battery charge design to optimize battery life
- Intuitive touch button interface
- Dual AC Output function
- Optional Battery Management System (BMS) specifications for enhanced battery communication and safety.
Important Safety Instructions
WARNING: This section contains critical safety information. Read and follow all instructions carefully to prevent electric shock, fire, or serious injury.
- Installation must be performed by qualified personnel in accordance with all local electrical codes.
- Ensure the inverter is securely disconnected from all power sources (PV, battery, AC input) before performing any maintenance or wiring.
- Use appropriate personal protective equipment (PPE) during installation and maintenance.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep children away from the inverter and its connections.
- Ensure proper ventilation around the inverter to prevent overheating.
- Do not expose the inverter to rain, snow, spray, or any liquids.
- The recommended AC breaker for the AC input power source is 63A for 10.2KW models.
- Use proper copper wiring of the correct gauge as specified in the installation section to reduce risk of injury and ensure system safety.
Installation Guide
Connection Diagram
The following diagram illustrates the typical connection setup for the hybrid solar inverter with various power sources and loads.

PV Connection
CAUTION: Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the Inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 63A for 7.2KW/8.2KW/10.2KW.
WARNING: It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested Cable Requirement for AC Wires
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 7.2KW / 8.2KW / 10.2KW | 10 AWG | 6 | 1.2 Nm |
PV Module Selection
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 11KW |
|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 90Vdc ~ 450Vdc |
Product Overview
Familiarize yourself with the components and indicators of your inverter.

| No. | Component | No. | Component | No. | Component |
|---|---|---|---|---|---|
| 1 | LCD display | 2 | Status indicator | 3 | Charging indicator |
| 4 | Fault indicator | 5 | Touch function buttons | 6 | Power on / off switch |
| 7 | AC input | 8 | Main output | 9 | Second output |
| 10 | PV1 & PV2 input | 11 | RS-232 / WIFI / Remove LCD communication port | 12 | Battery input |
Operation
LED Indicators
| LED Indicator | Messages | |
|---|---|---|
| INV/AC | Green Solid On | Output is powered by utility in Line mode. |
| Green Flashing | Output is powered by battery or PV in battery mode. | |
| CHG | Green Solid On | Battery is fully charged. |
| Green Flashing | Battery is charging. | |
| FAULT | Red Solid On | Fault occurs in the inverter. |
| Red Flashing | Warning condition occurs in the inverter. | |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
Various Working Modes
The inverter supports different working modes depending on battery connection and grid-tie settings.

Grid-Tie Operation Settings
The inverter can operate in Off-grid (default) or Hybrid mode. To change the mode:
- Press the ENTER key for 3 seconds to enter the setting mode.
- Navigate to setting number 37.
- Select "HYD" for Hybrid mode or "OFF" for Off-grid mode.
Note: The inverter's default mode is off-grid. You must manually set it to Hybrid mode if desired.
| Setting No. | Operation | Display | Description |
|---|---|---|---|
| 37 | GRID-tie operation | OFF | Inverter operates only in off-grid mode. Solar energy provides power to the loads as first priority and charging second. |
| Hybrid | HYD | Inverter operates in hybrid mode. Solar energy provides power to the loads as first priority and charging second. Excess energy feeds to grid. |

Dual AC Output Function
When there is no Main/AC IN/GRID INPUT, and the battery voltage is lower than the preset voltage, the main AC output will automatically cut off. In this scenario, the battery or PV only offers power for the second AC output.
Technical Specifications

| Parameter | Specification (AGH-10.2KW-PLUS) |
|---|---|
| GRID-TIE OPERATION | |
| Nominal DC Voltage/Maximum DC Voltage | 360VDC/500VDC |
| Start-up Voltage/Initial Feeding Voltage | 90VDC/120VDC |
| MPPT Voltage Range | 90-450VDC |
| Number of MPPT/Max Input Current | 2/18A |
| GRID OUTPUT (AC) | |
| Nominal Output Voltage | 220/230/240VAC |
| Output Voltage Range | 195-253VAC |
| Nominal Output Current | 44.3A |
| Power Factor | >0.99 |
| Feed-in Grid Frequency Range | 49-51.1Hz |
| EFFICIENCY | |
| Max Conversion Efficiency (DC/AC) | 96% |
| TWO LOAD OUTPUT POWER | |
| Nominal Output | 10200W |
| Maximum Main Load | 10200W |
| Max Second Load (battery mode) | 3400W |
| Main Load Cut Off Voltage | 52VDC |
| Main Load Return Voltage | 54VDC |
| OFF-GRID OPERATION | |
| AC INPUT | |
| AC Start-up Voltage / Auto Restart Voltage | 120-140VAC / 180VAC |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC |
| Maximum AC Input Current | 50A |
| Nominal Operating Frequency | 50/60Hz |
| Surge Power | 20400W |
| PV INPUT (DC) | |
| Maximum DC Voltage | 500VDC |
| MPPT Voltage Range | 90VDC - 450VDC |
| BATTERY MODE OUTPUT (AC) | |
| Nominal Output Voltage | 220/230/240VAC |
| Output Waveform | Pure sine wave |
| Efficiency (DC to AC) | 94% |
| BATTERY & CHARGER | |
| Nominal DC Voltage | 48VDC |
| Maximum Solar Charging Current | 160A |
| Maximum AC Charging Current | 140A |
| PHYSICAL | |
| Dimension (D*W*H)(mm) | 420*310*110 |
| Carton Dimension (D*W*H)(mm) | 588*463*205 |
| Net Weight (Kgs) | 14.5 |
| Gross Weight (Kgs) | 16.5 |
| INTERFACE | |
| Communication Port | RS232/WiFi/BMS |
| ENVIRONMENT | |
| Operating Temperature | -10~50°C |
Maintenance
- Regularly inspect the inverter for any signs of damage, loose connections, or corrosion.
- Ensure the ventilation openings are clear of dust and debris to maintain proper airflow.
- Clean the exterior of the inverter with a dry cloth. Do not use liquid cleaners.
- Check all wiring connections periodically to ensure they are tight and secure.
- Monitor the inverter's performance via the LCD display or WIFI app for any unusual readings or fault indicators.
- If the inverter is equipped with BMS, ensure proper communication with the battery for optimized charging and discharge cycles.
Troubleshooting
This section provides guidance for common issues. For complex problems, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No DC input from PV or battery; AC input not present; Power switch off. | Check PV connections and voltage; Verify battery connections and charge level; Ensure AC input is live; Turn on the power switch (6). |
| No AC output | Overload; Battery low; Fault indicator active; Dual AC output logic. | Reduce load; Check battery charge; Refer to LED indicator table for fault codes; Understand dual AC output behavior (main output may cut off if battery is low and no grid input). |
| Charging indicator not active | No PV input; Battery full; Charging disabled in settings. | Check PV connections and sunlight; Verify battery status; Check inverter settings for charging parameters. |
| Fault indicator (Red Solid On) | Internal fault; Over-temperature; Over-voltage/current. | Immediately disconnect all power sources. Allow inverter to cool. Reconnect after a few minutes. If fault persists, contact support. |
| WIFI connection issues | Incorrect setup; Router issues; Signal interference. | Ensure correct WIFI module installation and configuration. Check router status and signal strength. Refer to WIFI module specific instructions. |
User Tips
- BMS Integration: If your battery has a BMS, connecting it to the inverter's BMS port (if available on your model) allows for automatic adjustment of charging parameters, significantly extending battery life and enhancing safety.
- Hybrid Mode Activation: Remember that the inverter defaults to off-grid mode. To utilize grid-tie functionality and feed excess energy back to the grid, you must manually enable "Hybrid" mode via setting 37 on the inverter's display.
- Monitoring: Utilize the available WIFI feature to monitor your inverter's performance and battery status from your iOS or Android device for optimal system management.
Warranty and Support
This Daxtromn Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase.
The warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, unauthorized modifications, or natural disasters.
For technical support, warranty claims, or service inquiries, please contact your original point of purchase or the manufacturer's authorized service center.
Frequently Asked Questions (FAQ)
- Q: What is the rated output power of this inverter?
- A: The rated output power is 10200W (10.2KW).
- Q: What is the maximum charge current for the battery?
- A: The maximum solar charging current is 160A.
- Q: What is the maximum DC PV input voltage?
- A: The maximum DC PV input is 500VDC.
- Q: What voltage external battery should be used?
- A: This inverter is designed for a 48V external battery system.
- Q: Does this inverter support parallel operation?
- A: No, this model does not support parallel operation.
- Q: Does it have a WIFI module?
- A: Yes, it has a built-in WIFI module for monitoring.
- Q: Can it feed power back to the grid?
- A: Yes, it is an on/off-grid solar hybrid inverter, meaning it can feed excess power to the grid when configured in Hybrid mode.
- Q: Does the BMS specification model come with WIFI?
- A: Yes, models with BMS specifications also include WIFI.