1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sumry SP Series Pure Sine Wave Off-Grid Solar Inverter. This inverter combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It is designed for various applications, offering user-configurable settings via its comprehensive LCD display.
Key Features:
- Pure sine wave output.
- Programmable supply priority for PV, battery, or grid.
- High PV input voltage range (55~450VDC).
- Built-in Max 110A MPPT solar charger (3.8KW & 6.2KW models).
- Compatible with various battery types, including lithium-ion.
- Supports BMS communication with lithium batteries.
- Smart battery charge design to optimize battery life.
- Protection against overload, high temperature, and inverter output short circuit.
- Cold start function.
- Intelligent fan speed adjustment.
- Optional built-in anti-dusk kit for harsh environments.
- WiFi & GPRS available for iOS and Android (optional).
2. Safety Information
Always observe the following safety precautions during installation, operation, and maintenance of the inverter:
- Ensure proper grounding of the PE protective conductor.
- Disconnect all power sources (PV, battery, AC input) before performing any wiring or maintenance.
- Do not attempt to open or repair the inverter yourself. Refer to qualified service personnel.
- Keep the inverter away from flammable materials and ensure adequate ventilation to prevent overheating.
- Verify correct voltage and polarity for all connections to avoid damage to the inverter and connected devices.
- Install appropriate circuit breakers as specified in the installation section to protect against overcurrents and short circuits.
3. Setup and Installation
3.1 Unboxing and Product Overview
Carefully unpack the inverter and inspect it for any damage. The following video demonstrates the unboxing and provides a visual overview of the inverter's components and connection points.
Video: Unboxing and overview of the Sumry SP Series Inverter, showing connection terminals and display.
Below is an image highlighting the various connection points and technical specifications.

Image: Diagram illustrating wiring connections for generator, mains power, battery, solar panels, and home appliances, along with key technical specifications.
3.2 Detailed Installation Steps
Before installing and using the inverter, it is recommended to install 4 circuit breakers in the following positions:
- Between the battery pack and the inverter battery input.
- Between the solar panel and the photovoltaic input of the inverter.
- Between the power input of the grid and the inverter.
- Between inverter output and load.
The circuit breaker is to effectively prevent misconnection or reverse connection of the mains input and the inverter output. When there is a short circuit, load short circuit, or overload in the output, the circuit breaker can directly cut off the circuit to protect the inverter.
Step 1: Battery Connection
Install a circuit breaker between the battery and the inverter. After successful installation, open the breaker. Connect the battery to the inverter. For 3kW/3.8kW models, use a 24V battery. For 6.2kW models, use a 48V battery. Close the circuit breaker and measure the voltage on the battery side of the inverter to ensure it is normal.
Step 2: PV Input Connection
Install a circuit breaker between the PV input and the inverter. Turn on this circuit breaker after successful installation. Ensure the battery voltage is normal. Connect the solar panels to the inverter. Close the circuit breaker between the PV input and the inverter. The inverter display will automatically light up and begin charging. Press the button on the bottom right corner of the inverter (button 1) to start the machine. Verify that there is 220V/230V/240V AC voltage output from the inverter.
Step 3: AC Input and Output Connection
Install a circuit breaker between the AC input and the inverter, and another circuit breaker between the inverter's output and the load. After successful installation, turn on both AC input and output circuit breakers. Connect the machine to the mains. To test, turn off the mains input circuit breaker, then turn off the inverter's output circuit breaker after 2 minutes. This completes the installation procedure.

Image: Diagram illustrating the recommended placement of circuit breakers for battery, PV input, grid input, and AC output connections.
3.3 Circuit Breaker Specifications
- For 3kW machine:
- Battery to Inverter: 2P100A
- Photovoltaic Input to Inverter: 2P10A
- Utility Input to Inverter: 2P32A
- Inverter Output: 2P15A
- For 3.8kW machine:
- Battery to Inverter: 2P150A
- Photovoltaic Input to Inverter: 2P20A
- Utility Input to Inverter: 2P40A
- Inverter Output: 2P20A
- For 6.2kW machine:
- Battery to Inverter: 2P150A
- Photovoltaic Input to Inverter: 2P20A
- Utility Input to Inverter: 2P63A
- Inverter Output: 2P30A
3.4 Solar Panel Connection Guidelines
The number of solar panels required depends on the inverter model's PV charging power and voltage range, as well as the voltage and open-circuit voltage of your individual solar panels. The SP series inverters have a PV charging power of 3000W for 3kW models and 6000W for 3.8/6.2kW models, with a PV charging voltage range of 55-450V.
Refer to the diagram below for guidance on series and parallel wiring methods for solar panels. Ensure the entire photovoltaic system uses the same type of photovoltaic panel.

Image: Diagram illustrating series and parallel wiring methods for solar panels, including voltage and current considerations.
4. Operation
4.1 Working Modes
The Sumry SP Series inverter offers versatile working modes to optimize power management:
- Charging Modes:
- Only Solar
- Solar First
- Mains & Solar
- Output Modes:
- Solar First
- SBU First (Solar-Battery-Utility)
These modes allow you to customize the priority of power inputs and outputs for personalized energy consumption.

Image: Diagram illustrating the hybrid inverter's ability to mix solar, battery, and utility power, and its operation with and without AC power availability.
4.2 Monitoring and Control
The inverter can be monitored and controlled via a smartess App, available for download on the App Store or Google Play. This requires an optional WiFi module.

Image: Illustration of the inverter connected to a WiFi module for monitoring and control via a smartphone app.
5. Maintenance
To ensure optimal performance and longevity of your Sumry SP Series inverter, follow these maintenance guidelines:
- Cleaning: Regularly clean the exterior of the inverter, especially the ventilation grilles, to prevent dust accumulation. Use a soft, dry cloth. Do not use liquid cleaners.
- Ventilation: Ensure the inverter's intelligent fans are not obstructed. Proper airflow is crucial for heat dissipation.
- Connections: Periodically check all wiring connections for tightness and signs of corrosion. Loose connections can lead to overheating and poor performance.
- Battery Health: Monitor your battery's health and charge cycles. The smart battery charge design helps optimize battery life, but regular checks are still recommended.
- Firmware Updates: If using the optional WiFi module, check for available firmware updates through the smartess App to ensure your inverter has the latest features and bug fixes.

Image: Illustration highlighting the inverter's strong heat dissipation capabilities, crucial for reliable operation.
6. Troubleshooting
The Sumry SP Series inverter is equipped with several protection features. If you encounter issues, consider the following common scenarios:
- No Power Output: Check all circuit breakers (battery, PV, AC input, AC output) to ensure they are in the 'ON' position. Verify battery voltage and PV input voltage are within the specified ranges.
- Overload Protection: If the inverter shuts down due to overload, reduce the connected load. The inverter will automatically restart once the load is within limits. Ensure the total power consumption of connected appliances does not exceed the inverter's rated output.
- High Temperature Protection: If the inverter overheats, it will shut down. Check for obstructed ventilation fans or excessive ambient temperature. Allow the unit to cool down and ensure proper airflow.
- Short Circuit Protection: In case of a short circuit in the output, the inverter will activate protection. Identify and resolve the short circuit in the load or wiring before restarting the inverter.
- Battery Not Charging: Verify PV input connections and voltage. Check the solar charger settings on the LCD display or app to ensure the correct charging mode is selected.
- Communication Issues (WiFi/BMS): Ensure the optional WiFi module is correctly installed and configured. For BMS communication, confirm that the battery's communication protocol (PACE or PYLONTECH) is compatible and correctly set up.
7. Specifications
The following table provides detailed technical specifications for the Sumry SP Series inverters:

Image: Detailed specification table for Sumry SP-2200, SP-3200, SP-4200, and SP-7000 models, including rated power, input/output voltages, charge currents, and physical dimensions.
7.1 Battery Compatibility
The Sumry SP Series inverter is compatible with a wide range of battery types, ensuring flexibility for your energy storage needs.

Image: Diagram showing compatibility with various battery types including Flooded (FLD), Gel, Lithium-iron phosphate (LI), Lithium-ion (LI), AGM/Sealed (SLD), and User custom batteries.
8. Communication Options
The Sumry SP series inverters feature a single communication port (COMM port) located on the right side of the machine. This port allows for communication via either an optional WiFi module or a battery BMS (Battery Management System).
- WiFi Module: If you wish to monitor and control the inverter via the smartess App, you will need to purchase and install the optional WiFi module. Please ensure to select this option during purchase or contact the seller directly.
- Battery BMS Communication: If you intend to use battery BMS for communication, ensure your battery uses a compatible communication protocol such as PACE or PYLONTECH. Only one communication method (WiFi or BMS) can be active at a time.

Image: Diagram illustrating the optional WiFi module and its connection to the inverter for app-based monitoring and control.
9. User Tips
- Load Management: To maximize efficiency and prevent overloading, prioritize essential appliances and avoid running high-power devices simultaneously.
- Battery Sizing: Ensure your battery bank is adequately sized for your energy consumption needs and the inverter's capacity to provide sufficient backup power.
- Environmental Conditions: Install the inverter in a cool, dry, and well-ventilated area, away from direct sunlight and moisture, to ensure optimal performance and lifespan.
- Regular Checks: Periodically check the LCD display for any error codes or warnings and consult the troubleshooting section if necessary.
10. Warranty and Support
The Sumry SP Series Pure Sine Wave Inverter comes with a 1-year warranty. For technical support, service, or warranty claims, please contact your authorized dealer or the manufacturer's customer service. Ensure you have your product model and serial number available when seeking support.