Thermalright FW 240 X

Contents

Thermalright FW 240 X CPU Liquid Cooler User Manual

Model: FW 240 X

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Thermalright FW 240 X All-in-One (AIO) CPU Liquid Cooler. Please read this manual thoroughly before installation to ensure proper setup and optimal performance.

Thermalright FW 240 X White CPU Liquid Cooler

Figure 1: Thermalright FW 240 X White CPU Liquid Cooler with LCD display.

2. Package Contents

Before proceeding with installation, please verify that all components listed below are present in your package.

User Manual Components List

Figure 2: Component list from the user manual PDF.

The SS2 buckle system includes mounting hardware for various CPU sockets:

SS2 Buckle System Components

Figure 3: SS2 Buckle System components for Intel and AMD platforms.

  • FW 240 X Radiator and Pump/Cold Plate Unit
  • Intel Mounting Brackets (LGA1700, LGA115X/1200, LGA2066/2011)
  • AMD Mounting Brackets (AM5, AM4)
  • Backplates for Intel Sockets
  • Mounting Screws and Standoffs
  • Thermalright TF7 Thermal Grease
  • USB Cable for LCD Display
  • User Manual (this document)

3. Installation Guide

Caution: All liquid coolers have a probability of leakage. Please closely follow the instructions to install and always check the cooler before installation. If there is any defect or deformation in the cooler, please contact customer service immediately.

3.1. Prepare Your Motherboard

  1. Intel Backplate Installation (LGA 115X/1700):

    For Intel LGA 115X/1700 sockets, install the appropriate backplate. Adjust the backplate according to your CPU socket type (LGA 115X/1200 or LGA 1700/1851).

    Intel LGA 115X/1700 Backplate Installation Diagram

    Figure 4: Intel LGA 115X/1700 backplate installation and adjustment diagram from the user manual PDF.

  2. Install Mounting Standoffs: Screw the correct standoffs into the motherboard's CPU socket holes. Use the appropriate standoffs for your Intel or AMD platform as shown in the SS2 buckle system diagram (Figure 3).

3.2. Apply Thermal Paste

  1. Clean the CPU surface with isopropyl alcohol.
  2. Apply a small pea-sized amount of the provided Thermalright TF7 thermal grease to the center of your CPU's integrated heat spreader (IHS).
  3. Thermalright TF7 Thermal Grease

    Figure 5: Thermalright TF7 heat conduction silicone grease.

3.3. Install Pump/Cold Plate

  1. Attach the correct mounting brackets (Intel or AMD) to the pump/cold plate unit.
  2. Carefully place the pump/cold plate unit onto the CPU, aligning the holes in the mounting bracket with the standoffs.
  3. Secure the pump/cold plate unit by tightening the thumb screws in a cross pattern until snug. Do not overtighten.

3.4. Mount Radiator

  1. Mount the radiator to an available fan mount location in your PC case (e.g., front, top, or rear). Use the provided screws to secure the radiator.

3.5. Connect Cables

  1. Pump Power: Connect the 4-pin pump cable from the pump unit to the CPU_FAN or AIO_PUMP header on your motherboard.
  2. LCD Display: Connect the provided USB cable from the pump unit to an available internal USB 2.0 header on your motherboard.

4. Operation

4.1. LCD Display

The FW 240 X features a 2.4-inch IPS LCD display on the pump unit, providing real-time system information and customization options.

  • Resolution: 320*240
  • Brightness: 450 Nits peak brightness
  • Color Depth: 24-bit color
  • Customization: Supports personalized JPG, PNG, and GIF images for display.
LCD Display showing CPU temperature

Figure 6: Close-up of the LCD display showing CPU temperature and frequency.

LCD Display Visuals

Figure 7: Examples of visual content on the 320*240 resolution IPS LCD screen.

4.2. TRCC Control Software

To fully utilize the customization features of the LCD display and monitor various system parameters, install the Thermalright TRCC water-cooled LCD screen control software.

  • Custom Theme: Design and apply custom themes for your display.
  • Parameter Display: Monitor various system states (M1-M6) and parameters.
  • Background Replacement: Change the display background without altering system status.
  • Software Help: An explanation document is available within the software interface.
TRCC Software Interface

Figure 8: Screenshots of the TRCC water-cooled LCD screen control software interface.

Please download the latest version of the TRCC software from the official Thermalright website.

5. Maintenance

  • Radiator Fins: Periodically inspect the radiator fins for dust buildup. Use compressed air to gently clean the fins to ensure optimal airflow and cooling performance.
  • Cable Connections: Ensure all cables (pump power, USB) are securely connected to the motherboard.
  • System Monitoring: Regularly monitor CPU temperatures using the LCD display or system monitoring software to ensure the cooler is functioning effectively.
  • No User-Serviceable Parts: The AIO liquid cooler is a sealed unit. Do not attempt to open the pump or radiator as this will void the warranty and may cause damage or leakage.

6. Troubleshooting

6.1. LCD Display Not Working

  • Ensure the USB cable is securely connected to both the pump unit and an internal USB 2.0 header on your motherboard.
  • Check if the TRCC software is installed and running correctly.
  • Try connecting the USB cable to a different internal USB header.
  • Restart your computer.

6.2. High CPU Temperatures

  • Verify that the pump/cold plate unit is securely mounted to the CPU and that the thermal paste application is adequate.
  • Ensure the radiator is properly installed and has unobstructed airflow.
  • Check that the pump is receiving power and operating (you may feel a slight vibration or hear a faint hum).
  • Confirm that the pump speed is set appropriately in your motherboard's BIOS/UEFI or through software.

6.3. Pump Noise

  • Ensure the pump is mounted correctly and not vibrating against other components.
  • Adjust pump speed settings in your motherboard's BIOS/UEFI or software.
  • Some minor noise is normal during operation. If the noise is excessive or unusual, contact support.

6.4. TRCC Software Issues

  • Ensure you have downloaded the correct version of the software for your operating system.
  • Try reinstalling the TRCC software.
  • Check the official Thermalright website for software updates or FAQs.

7. Specifications

FeatureSpecification
ModelFW 240 X
Radiator Type240mm All-in-One Liquid Cooler
Radiator Dimensions277mm (L) x 120mm (W) x 27mm (H)
Cold Head Dimensions69.2mm (L) x 69.2mm (W) x 60mm (H)
Water Guide Length450mm
Heatsink MaterialCopper & Aluminum
Supported CPU SocketsIntel: LGA 1851 / 1700 / 115X / 1200 / 2011 / 2066
AMD: AM5 / AM4
Pump Interface4-PIN PWM
LCD Display2.4-inch IPS, 320x240 resolution, 450 Nits, 24-bit color
Thermal PasteThermalright TF7 (12.8W/mk)
Pump TechnologyCorev1.0 independent water pump, 9-pole rotor motor
RGB SupportNo RGB (LCD is customizable)
Warranty3 Years
Corev1.0 Water Pump Framework Diagram

Figure 9: Corev1.0 independent water pump framework details.

8. User Tips

  • LCD Display Care: The LCD display is a prominent feature. If it stops functioning, first check all USB connections and ensure the TRCC software is running. If issues persist, consult the troubleshooting section or contact support.
  • Software Customization: Take advantage of the TRCC software to personalize your LCD display with custom images or GIFs to match your system's aesthetic.

9. Warranty and Support

The Thermalright FW 240 X CPU Liquid Cooler comes with a 3-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For technical support, warranty claims, or further assistance, please contact your retailer or visit the official Thermalright website. Please have your proof of purchase and product serial number ready when contacting support.

For detailed diagrams and further instructions, you may also refer to the official user manual PDF provided by the manufacturer.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.