1. Product Overview
The BTMETER BT-570T-APP is an intelligent digital AC/DC clamp multimeter featuring 4000 counts and automatic range selection. It can measure DC and AC voltage, resistance, capacitance, frequency, and duty cycle. This device supports a backlit screen, data hold, temperature measurement, diode test, relative value measurement, and continuity check with an alarm buzzer. It connects to a mobile phone via an app for logging and monitoring electrical measurement data, including AC/DC current, voltage, resistance, and temperature, with data saving and sharing capabilities in TXT and Excel formats. Designed with a rugged edge cover for durability, it meets IEC 61010-1, CAT IV 600 V, CAT III 1000 V safety standards with double insulation.

2. Safety Information
Always observe basic safety precautions when using this multimeter to avoid personal injury or damage to the meter or equipment under test. Read the following safety information carefully before use.
- Do not input voltage exceeding 1000V DC or 750V AC.
- Be cautious against electric shock when measuring high voltage.
- When checking in-circuit resistance, ensure the circuit under test has all power removed and that all capacitors have been discharged fully.
- Do not import voltage in the temperature function.
- Before measuring AC current, disconnect the test leads from the meter for safety.
- Ensure the hot and neutral conductors are separated when measuring AC current with the clamp, otherwise, they will cancel each other out and result in a zero ampere value.
- The meter is designed with a rugged rubber sleeve for protection against falls.
- This device is qualified with electrical IEC 61010-1, CAT IV 600 V, CAT III 1000 V, class 2, safety standards with double insulation.
3. Product Features
The BTMETER BT-570T-APP offers a comprehensive set of features for various electrical measurements:
- Measurement Capabilities: DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Capacitance, Frequency, Duty Cycle, Temperature.
- Display: 4000 counts digital display with backlight for easy reading in dark environments.
- Operating Mode: Auto Range for simplified operation.
- Smart Features: Bluetooth connectivity to mobile phone with Ailink APP for logging, monitoring, and data analysis.
- Data Management: Measurement and display of Max, Min, and Average values over time. Save and share files in TXT and Excel formats.
- Additional Functions: Continuity test with alarm buzzer (beeps if resistance < 100 Ω), Diode test, Data Hold, Auto Zero, Low Battery Indication.
- Safety: Overload protection, rugged rubber sleeve for drop protection, double insulation, CAT IV 600 V, CAT III 1000 V safety ratings.
- Jaw Caliber Size: 1.77 inch (45 mm) for non-contact AC current measurement.

4. Components and Layout Introduction

- Clamp Jaws: Opens 45mm to enclose conductors for current measurement.
- Jaw-Opening Handle: Used to open and close the clamp jaws.
- Rotary Switch: Use this switch to select functions and measurement ranges.
- HOLD Key: Press to hold the current reading. Press and hold for more than 2 seconds to turn on/off the backlight.
- SELECT Key: Used to switch between different measurement modes (e.g., AC/DC voltage, resistance, continuity, diode, capacitance) within a rotary switch position.
- RANGE Key: Press to manually select measurement ranges. Press and hold for more than 2 seconds to return to auto mode.
- MAX/MIN Key: Press to lock the maximum or minimum value during measurement. Press and hold for 2 seconds to exit.
- REL Key: Used for relative value measurement.
- Hz/Duty Key: In ACV/ACA or Hz range, press this key to choose Frequency or Duty Cycle measurement.
- LCD Display: 4000 counts digital display, showing full function symbols.
- COM Terminal: Common terminal for test leads.
- VΩHzT+ Terminal: Positive input terminal for voltage, resistance, frequency, temperature, and other measurements.
5. Setup
5.1. Battery Installation
The BT-570T-APP does not include a battery. Please install a 9V battery (not included) into the battery compartment located on the back of the device before first use. Ensure correct polarity.
5.2. APP Connection (Ailink APP)
The multimeter can connect to your mobile phone via Bluetooth for enhanced functionality.
- Download and Install the APP: Scan the QR code provided in the manual or search for "Intelligent Meter" in your device's app store (App Store for iOS, Google Play for Android) to download and install the "Intelligent Meter" app.
- Register/Log In: Open the Ailink APP. Register a new account or log in using an existing account (e.g., Facebook, Apple ID).
- Connect the Clamp Meter: In the app, navigate to the device connection section (often labeled "Devices" or similar). Press "Add" or the "+" icon to search for nearby devices. Ensure your multimeter is powered on. Select "Clamp Meter" from the list of found devices.

Video 1: Product demonstration including APP connection, DC voltage test, AC voltage test, resistance test, temperature test, and AC current test.
6. Operating Instructions
6.1. DC Voltage Test
To measure DC voltage:
- Turn the rotary switch to the "V=" position.
- Insert the red test lead into the VΩHzT+ terminal and the black test lead into the COM terminal.
- Connect the test leads across the component or circuit to be measured.
- Read the DC voltage value on the LCD display.
Caution: Do not input voltage more than 1000V DC. Exceeding this limit can damage the meter.
6.2. AC Voltage Test
To measure AC voltage:
- Turn the rotary switch to the "V~" position.
- Insert the red test lead into the VΩHzT+ terminal and the black test lead into the COM terminal.
- Connect the test leads across the component or circuit to be measured.
- Read the AC voltage value on the LCD display.
Caution: Be cautious against electric shock when measuring high voltage. Do not input voltage more than 750V AC.
6.3. Resistance Test
To measure resistance:
- Turn the rotary switch to the "Ω" position.
- Insert the red test lead into the VΩHzT+ terminal and the black test lead into the COM terminal.
- Ensure the circuit under test has all power removed and that all capacitors have been discharged fully before connecting the test leads.
- Connect the test leads across the component to be measured.
- Read the resistance value on the LCD display.
6.4. Temperature Test
To measure temperature:
- Turn the rotary switch to the "℃/℉" position.
- Connect the thermocouple probe to the VΩHzT+ and COM terminals, ensuring correct polarity.
- Place the thermocouple probe in contact with the object or environment whose temperature is to be measured.
- Read the temperature value on the LCD display. Use the SELECT key to switch between Celsius and Fahrenheit if needed.
Caution: Do not import voltage in the temperature function. Only use the provided thermocouple probe for temperature measurements.

6.5. AC Current Test
To measure AC current:
- Turn the rotary switch to the "400A" or "1000A" AC position.
- Important: Before this measurement, disconnect the test leads from the meter for safety.
- Open the clamp jaws using the jaw-opening handle.
- Enclose a single conductor (LIVE line or NULL line) with the clamp jaws. Ensure the hot and neutral conductors are separated; otherwise, they will cancel each other out, resulting in a zero ampere value.
- Read the AC current value on the LCD display.
- If the reading is hard to read in certain situations, push the HOLD button to freeze the display and read the result later.
7. Specifications
The following table details the specifications for the BTMETER BT-570T-APP:

| Parameter | Value |
|---|---|
| Brand Name | BTMETER |
| Model Number | BT-570T-APP |
| Display Type | Digital Display (4000 counts) |
| Operating Mode | Auto Range |
| Battery Included | No (Requires 9V battery) |
| Is Smart Device | Yes (APP Connectivity) |
| High-concerned chemical | None |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Data Storage | Yes |
| Diode Test | Yes |
| Automatic Shutdown | Yes |
| Backlit Display | Yes |
| Overload Protection | Yes |
| Phone APP Connection | Yes |
| Measurement | Range | Resolution | Accuracy |
|---|---|---|---|
| DC Voltage | 600mV/6/60/600/1000V | 0.1mV - 1V | ±(0.5% rdg + 2 digits) |
| AC Voltage | 6/60/600/750V | 1mV - 1V | ±(1.0% rdg + 3 digits) |
| DC Current | 600/1000A | 100mA - 1A | ±(2.5% rdg + 10 digits) |
| AC Current | 600/1000A | 100mA - 1A | ±(2.5% rdg + 10 digits) |
| Resistance | 400Ω/4/40/400kΩ/4/40MΩ | 0.1Ω - 10kΩ | ±(1.0% rdg + 3 digits) |
| Capacitance | 4nF~200uF (570T-APP) | ||
| Temperature | ℃/℉ |
8. Maintenance
- Cleaning: Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Battery Replacement: When the low battery indicator appears on the display, replace the 9V battery immediately to ensure accurate readings. Turn off the meter, open the battery compartment cover on the back, replace the battery, and secure the cover.
- Storage: If the meter is not used for a long period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
- Protection: The meter is equipped with a rubber sleeve to protect it from minor impacts. However, avoid dropping the device from significant heights.
9. Troubleshooting
If you encounter issues with your BTMETER BT-570T-APP, try the following:
- No Display/Faint Display: Check the battery. Replace with a fresh 9V battery if necessary.
- Incorrect Readings: Ensure test leads are properly connected to the correct terminals. Verify the rotary switch is set to the appropriate function and range. For current measurements, ensure only one conductor is clamped.
- APP Connection Issues: Make sure Bluetooth is enabled on your phone and the multimeter. Restart both the app and the multimeter. Ensure you have the latest version of the "Intelligent Meter" app.
- "OL" (Overload) Display: This indicates that the input value exceeds the selected range. Switch to a higher range or verify the circuit conditions.
- Buzzer Not Working: Check if the continuity function is selected and if the resistance is below 100 Ω.
If problems persist, contact customer support for assistance.
10. User Tips
- Data Logging: Utilize the Ailink APP's data logging feature for long-term monitoring of electrical parameters. This is especially useful for identifying intermittent issues or tracking performance over time.
- Backlight Use: The backlight feature is excellent for dimly lit areas. Remember to press and hold the HOLD button for more than 2 seconds to activate or deactivate it, conserving battery life when not needed.
- Safety First: Always double-check your connections and selected function before taking any measurements, especially when dealing with live circuits.
11. Warranty and Support
All products from our store come with a 1-year warranty. For technical support, troubleshooting assistance, or warranty claims, please contact the RUISI Tools Store directly through the platform where you purchased the product.