WinAPEX 268B Leakage Current Detect Clamp Meter User Manual
Model: 268B
1. Introduction
The WinAPEX 268B is a high-precision True RMS clamp meter designed for detecting AC and DC leakage currents, as well as performing various multimeter functions. Its compact design, screen rotation feature, and clear LCD display make it suitable for both professional and home applications. This manual provides detailed instructions for safe and effective use of the device.
2. Package Contents
Upon opening your WinAPEX 268B package, please ensure all the following items are present:
- 1 x WinAPEX 268B Clamp Meter
- 1 x Pair of Test Leads (Red and Black)
- 1 x User Manual
- 1 x Thermocouple
- 1 x Type-C Cable
- 1 x Storage Bag
Figure 2.1: Package List
3. Device Layout and Controls
Familiarize yourself with the main components and controls of your WinAPEX 268B Clamp Meter:
Figure 3.1: Operation Interface Overview
- Jaw: Used for non-contact current measurement.
- Trigger: Opens and closes the jaw.
- On/Off/Function Selection (SELECT) Button: Powers the device on/off and cycles through measurement functions.
- HOLD / Backlight Adjustment Button: Short press to hold the current reading; long press to adjust screen brightness.
- EF / LIVE Button: Short press for Non-Contact Voltage (NCV) detection; long press for Live Wire detection.
- ZERO Button: Used to zero the DC current reading before measurement.
- Flashlight Button: Activates the built-in flashlight.
- Type-C Port: For charging the internal battery.
- Test Lead Sockets (COM, VΩ): For connecting test leads for voltage, resistance, capacitance, diode, and continuity measurements.
4. Setup and Charging
4.1 Initial Setup
Before first use, ensure the device is fully charged. Connect the provided Type-C cable to the meter and a suitable USB power source.
4.2 Charging the Battery
The WinAPEX 268B features a built-in 3.7V lithium battery with a capacity of 750mAh, providing approximately 20 hours of continuous use on a full charge. Use the included Type-C cable to charge the device. The charging port is located on the side of the meter.
Figure 4.1: Type-C Charging
5. Operating Instructions
This section details how to use the various measurement functions of your clamp meter.
5.1 Power On/Off and Function Selection
Press and hold the On/Off/Function Selection button to power the device on or off. Short press this button to cycle through different measurement modes (e.g., AC/DC voltage, resistance, capacitance, etc.).
5.2 Brightness Adjustment
To adjust the screen brightness, long press the HOLD button. The display will show a brightness indicator, allowing you to select from 5 levels suitable for various environments.
Video 5.1: Demonstrating Brightness Adjustment and other features.
5.3 Screen Rotation
The screen can be rotated for easier viewing, especially when operating with both hands or in awkward positions. Long press the dedicated screen rotation button (often integrated with the current switching button) to rotate the display.
Figure 5.1: Screen Rotation
5.4 AC Current Measurement
To measure AC current, select the AC current mode. Open the clamp jaw using the trigger and enclose a single live wire (not the entire cable with multiple wires). The current reading will be displayed on the screen.
Figure 5.2: AC Current Measurement (part of Intelligent Recognition)
5.5 DC Current Detection
For DC current detection (range 6A-60A, minimum measured 5mA), select the DC current mode. Close the pliers and press the "ZERO" key to reset before testing. Then, clamp a single DC wire to measure the current.
Figure 5.3: DC Current Detection
5.6 AC Leakage Current Detection
To detect AC leakage current (range 600mA-60A, minimum measured 2mA), clamp both the neutral and live wires at the same time. A normal clamp meter would show nothing in this scenario. The WinAPEX 268B will display the leakage current. For example, if the neutral wire measures 2.3mA and the live wire measures 4.6mA, the cable has a leakage of 4.6mA.
Figure 5.4: AC Leakage Current Detection
5.7 Automatic Identification (AC/DC Voltage, Resistance, Buzzer)
The meter can automatically identify AC voltage, DC voltage, resistance, and buzzer functions when test leads are connected. Simply connect the test leads to the circuit or component, and the meter will display the appropriate measurement.
Figure 5.5: Automatic Identification
5.8 Capacitance Measurement
Connect the test leads to the capacitance terminals of the component. The meter will display the capacitance value.
Figure 5.6: Capacitance Measurement
5.9 Temperature Measurement
Connect the provided thermocouple to the meter's input jacks. Place the tip of the thermocouple on the object whose temperature you wish to measure. The display will show the temperature in Celsius or Fahrenheit.
Figure 5.7: Temperature Measurement
5.10 NCV (Non-Contact Voltage) Measurement
Short press the EF / LIVE button to enter NCV mode. Hold the meter near an AC voltage source. When AC voltage is nearby, the buzzer will sound continuously, and the LCD will display different segments according to the strength of the signal. "EF" means no signal.
Figure 5.8: NCV Measurement
5.11 Live Wire Measurement
Long press the EF / LIVE button to enter Live Wire mode. Insert the red test lead into the live socket of a power outlet. If it's a live wire, the buzzer will sound and the screen will display "OL".
Figure 5.9: Live Wire Measurement
5.12 Diode and Continuity Test
Select the diode/continuity mode. Connect the test leads across the diode or circuit. For diode test, the forward voltage drop will be displayed. For continuity, the buzzer emits a long sound when the resistance value between two points is tested to be less than a certain threshold (typically 50Ω).
Figure 5.10: Diode and Continuity Test
5.13 Data Retention (HOLD)
Press the HOLD button to freeze the current reading on the display. Press it again to release and resume live measurements.
5.14 Flashlight
Press the flashlight button to turn on the built-in flashlight, which helps illuminate the work area in low-light conditions. Press it again to turn it off.
Figure 5.11: Flashlight Function
6. Specifications
| Parameter | Value |
|---|---|
| Brand Name | easyover (WinAPEX) |
| Model Number | 268B |
| Dimensions | 165x68x26mm |
| Operating Temperature | 0-40°C |
| Display Type | Digital Only |
| Measuring AC Voltage Range | 6V/60V/600V/750V |
| Measuring DC Voltage Range | 6V/60V/600V/1000V |
| Measuring AC Current Range | 600mA/6A/60A |
| Measuring DC Current Range | 6A/60A |
| Measuring Resistance Range | 600Ω/ 6kΩ/ 60kΩ/ 600kΩ/ 6MΩ/ 60MΩ |
| Measuring Capacitance Range | 6nF/60nF/600nF/6uF/60uF/600uF/6mF/60mF |
| Measuring Frequency Range | 6Hz/60Hz/600Hz/6kHz/60kHz/600kHz/6MHz/10MHz |
| Temperature Measurement | (-20-1000)°C / (0-1832)°F |
| Measuring Inductance Range | N/A |
| Battery Included | Yes |
| Certification | CE, RoHS |
Figure 6.1: Capacitance, Frequency, and Temperature Specifications
Figure 6.2: Voltage, Current, Resistance, and Diode Specifications
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the meter. Do not use abrasives or solvents.
- Storage: When not in use for extended periods, store the meter in its protective bag in a cool, dry place.
- Battery Care: Recharge the battery regularly to maintain its lifespan, even if the device is not frequently used.
- Calibration: For professional use, periodic calibration by a qualified technician is recommended to ensure accuracy.
8. Troubleshooting
- No Display: Ensure the device is powered on. Check if the battery is charged. If the battery is low, connect the Type-C charger.
- Inaccurate Readings: Verify that the correct measurement mode is selected. Ensure test leads are properly connected and not damaged. For current measurements, ensure only a single wire is clamped (unless performing leakage detection).
- No Response from Buttons: Try turning the device off and on again. If the issue persists, the device may require service.
- "OL" or "EF" Display: "OL" (Overload) indicates the measured value exceeds the range. "EF" (Electric Field) is displayed in NCV mode when no AC voltage is detected.
9. User Tips
- Safety First: Always prioritize safety when working with electrical circuits. Ensure power is off before making connections, and use appropriate personal protective equipment.
- Zero DC Current: For accurate DC current measurements, always press the ZERO button before clamping the wire to eliminate any residual magnetic fields.
- Screen Visibility: Utilize the brightness adjustment and screen rotation features to ensure clear visibility of readings in all working conditions.
- Versatile Tool: The WinAPEX 268B is a super versatile tool for various electrical tasks, from basic voltage checks to advanced leakage current detection.
10. Frequently Asked Questions (FAQ)
- Q: Can this meter measure both AC and DC current?
- A: Yes, the WinAPEX 268B is capable of measuring both AC and DC current, including leakage currents.
- Q: How do I know if there is a leakage in my electrical system?
- A: To detect AC leakage current, clamp both the neutral and live wires simultaneously. If the meter shows a reading other than 0.00mA, it indicates a leakage.
- Q: Is the battery rechargeable?
- A: Yes, the meter has a built-in rechargeable 3.7V lithium battery and can be charged via the included Type-C cable.
- Q: What does the NCV function do?
- A: NCV (Non-Contact Voltage) allows you to detect the presence of AC voltage without direct contact with the wires, providing an audible and visual indication.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the manufacturer's official website. Keep your purchase receipt as proof of purchase.