1. Introduction
This manual provides essential instructions for the safe and efficient operation of your ZJIVNV S-2000 series 2000W Switching Power Supply. This device is designed to provide a stable and adjustable power source with a digital display for precise voltage and current control. It is suitable for a wide range of electronic equipment and industrial applications.

2. Safety Information
Please read and understand all safety warnings and operating instructions before installing or using this power supply. Failure to do so may result in injury or damage to the equipment.
- **Environmental Conditions:** Operating the power supply in abnormal environments (e.g., extreme temperatures, high humidity, excessive dust, acid-base pollution) will reduce its service life.
- **Packaging Removal:** Always remove all plastic packaging before installation to ensure proper ventilation and prevent overheating.
- **Mounting Screws:** Do not use screws that are too long when mounting, as they may damage internal circuit boards or components.
- **Input Voltage Selection:** Before powering on, ensure the AC input voltage switch is correctly set to either 115V or 230V to match your local power supply. Incorrect selection can severely damage the unit.
- **Voltage Fluctuations:** If your power supply experiences dramatic voltage fluctuations (over-voltage/low-voltage), consider installing a power stabilizer or an over/under voltage protector before connecting the power supply to your equipment.
- **Large Electrical Equipment:** When supplying power to large electrical equipment, consider installing an AC filter to protect the power supply and connected devices.
- **Ventilation:** Ensure the power supply operates in an environment with unblocked airflow. Restricted airflow can lead to overheating and shorten the product's lifespan.
- **Temperature Derating:** If the ambient temperature exceeds the normal operating range (-10°C to 40°C), reduce the output power according to the power-output curve. For example, at 70°C, the output power should not exceed 50% of its rated capacity.
- **Cold Start:** If the ambient temperature is below -10°C, the switching power supply may not start or output normally.

3. Product Features
- High Power Output: Provides up to 2000W of power.
- Adjustable Output: Both output voltage and current are fully adjustable.
- Digital Display: Integrated digital display for real-time monitoring of output voltage and current.
- Dual Input Voltage: Supports 110VAC and 220VAC input, selectable via a switch.
- Compact Design: Small footprint for space-saving installations.
- Constant Voltage & Current: Operates in both constant voltage (CV) and constant current (CC) modes.
- Efficient Cooling: Equipped with cooling fans to maintain optimal operating temperature.
- Robust Construction: Features pure copper coils and transformers for durability and high performance.
- Comprehensive Protection: Includes short circuit protection, overload protection, and over-temperature protection.
- Versatile Applications: Ideal for automated industry, electric equipment, scientific research, LED lighting, and other electronic devices.

4. Specifications
| Parameter | Specification |
|---|---|
| Model Number | S-2000 |
| Type | Power Supply |
| Rated Capacity | 40-1000VA |
| Output Power | 2000W |
| Output Frequency | 24k |
| Output Type | SINGLE |
| Certification | CE, FCC, WEEE |
| Product Size (L*W*H) | 280mm * 140mm * 67mm |
| Net Weight | 1.62 kg |
| Input Voltage Range | 90~130VAC / 190~240VAC (47-63Hz) |
| Input Current | 12A/230V |
| AC Inrush Current | 50A/230V |
| Leakage Current | <3.5mA/240VAC |
| Output Voltage Range | Adjustable (e.g., 0-24V, 0-36V, 0-48V, 0-60V, 0-72V, 0-80V, 0-100V, 0-110V, 0-150V) |
| Output Current Range | Varies by voltage (e.g., 0-83A for 0-24V) |
| Output Voltage Accuracy | ±1% |
| Wave and Noise (mVp-p) | 200 |
| Inlet Stability | ±0.5% |
| Load Stability | ±0.5% |
| Efficiency | 84-87% |
| Overload Protection | 105%-150% (Pulsing hiccup shutdown, auto recovery) |
| Over-voltage Protection | Varies by model (e.g., 13.8~16.2V for 12V output) |
| High-temperature Protection | ≥70°C (Cut off output at 0-50°C) |
| Working Temperature & Humidity | -10°C ~ +60°C, 10% ~ 95%RH |
| Storage Temperature & Humidity | -20°C ~ +85°C, 10% ~ 95%RH |
For a visual representation of detailed specifications, please refer to the image below: Detailed Specifications Table
5. Setup and Installation
- **Unpacking:** Carefully remove the power supply from its packaging. Inspect for any signs of damage.
- **Input Voltage Selection:** Locate the 110V/220V selector switch on the unit. Ensure it is set to match your local AC mains voltage before connecting any power.
- **Wiring Connections:**
- AC Input: Connect the live wire to 'L', neutral wire to 'N', and earth wire to the ground terminal (marked with the earth symbol ④). Ensure the cross-section of the input electric wire is sufficient (AC voltage reduction should not exceed 5%).
- DC Output: Connect the positive pole of your load to '+V' and the negative pole to '-V'. For multiple DC outputs, terminals may be marked '+V1', '+V2', etc., or directly with voltage values. 'COM' indicates a common multiplex interface.
- Adjustment Terminals: The unit features potentiometers for adjusting output voltage and current. These are typically labeled 'Adjust Voltage' and 'Adjust Current'.
- **Secure Connections:** Verify that all screw connections for input and output lines are tight and have good contact.
- **Grounding:** The earth wire must be firmly grounded to ensure safety and reduce interference. The surface area of the grounded copper wire should exceed 0.75mm².
- **Insulation Check:** Before powering on, check the insulation resistance and withstand voltage between the shell and input/output terminals to ensure they meet required safety standards.

6. Operating Instructions
- **Power On:** After ensuring all connections are secure and the input voltage switch is correctly set, connect the power supply to the AC mains. The digital display should illuminate.
- **Voltage Adjustment:** Use the 'Adjust Voltage' potentiometer to set the desired output voltage. Monitor the digital display for the current voltage reading.
- **Current Adjustment:** Use the 'Adjust Current' potentiometer to set the desired output current limit. Monitor the digital display for the current reading.
- **Main vs. Secondary Output:** If your model has multiple outputs, the main output typically has superior characteristics (higher rated current, more stable load power). If using only secondary outputs, a dummy load of at least 30% of the rated power output should be added to the main output for optimal performance (unless it's a custom-made or dedicated power supply).
- **Monitoring:** Continuously monitor the digital display for output voltage and current during operation.
7. Maintenance
- **Cleaning:** Regularly clean the exterior of the power supply with a soft, dry cloth. Do not use liquid cleaners or solvents.
- **Ventilation:** Ensure that the cooling fans and ventilation openings are free from dust and obstructions. Periodically clean the fan blades if necessary to maintain efficient cooling.
- **Connection Check:** Periodically inspect all wiring connections for tightness and signs of wear or corrosion. Re-tighten any loose connections.
- **Environmental Monitoring:** Ensure the operating environment remains within the specified temperature and humidity ranges to prolong the unit's lifespan.

8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No power/No output | Incorrect input voltage selection Loose power connections Ambient temperature too low | Verify 110V/220V switch setting Check all input/output wiring Ensure ambient temperature is above -10°C |
| Output voltage/current unstable | Input voltage fluctuations Overload condition Poor ventilation | Consider a power stabilizer Reduce load or check for short circuits Ensure adequate airflow around the unit |
| Unit overheats | Insufficient ventilation Excessive load High ambient temperature | Clear obstructions from vents/fans Reduce load Operate in a cooler environment or reduce output power |
| Protection circuit activated | Short circuit, overload, or over-temperature | Identify and resolve the fault (e.g., remove short, reduce load). The unit should auto-recover. |
9. User Tips
- Always double-check the input voltage selector switch (110V/220V) before connecting the power supply to the mains.
- Ensure the earth wire is properly connected for both safety and to minimize electrical interference.
- Provide ample space around the power supply for proper air circulation to prevent overheating and ensure a long operational life.
- When adjusting output voltage or current, make small, gradual changes and observe the digital display for precise control.
- For models with secondary outputs, consider adding a dummy load to the main output if only secondary outputs are in use, as specified in the operating instructions.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Refer to the official product documentation for specific warranty terms and conditions.
Additional item guides and documents, including a user manual in PDF format, may be available. You can typically find these resources on the product's support page or by contacting the seller. A PDF version of the user manual is available here: ZJIVNV S-2000 Series User Manual (PDF).