1. Product Overview
The Sumry SP Series Hybrid Solar Inverter is an advanced off-grid power solution designed to provide uninterruptible power support. It integrates the functions of a solar inverter, MPPT solar charger, and battery charger into a compact unit. This inverter is capable of delivering pure sine wave output, ensuring compatibility with a wide range of sensitive electronic appliances.

Key Features:
- Pure sine wave output for sensitive electronics.
- Programmable supply priority for PV, battery, or Grid.
- High PV input voltage range (55-450VDC).
- Built-in Max 110A (for 3.8KW & 6.2KW models) MPPT solar charger.
- Compatible with lithium-ion batteries and supports BMS communication.
- Smart battery charge design to optimize battery life.
- Overload, high temperature, and inverter output short circuit protection.
- Cold start function.
- Intelligent fan speed adjustment for efficient cooling.
- Built-in anti-dusk kit for harsh environments (optional).
- WiFi & GPRS available for iOS and Android monitoring (optional).

2. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your Sumry Hybrid Solar Inverter. Please follow these steps carefully. It is recommended to have a qualified electrician perform the installation.
Installation Steps:
- Battery Connection: Install a circuit breaker between the battery and the inverter. After successful installation, open the breaker. Connect the battery (24V for 3KW/3.8KW models, 48V for 6.2KW models). Close the circuit breaker and measure the voltage on the battery side of the inverter to ensure it is normal.
- PV Input Connection: Install a circuit breaker between the PV input and the inverter. Turn on this circuit breaker after successful installation. Ensure the battery voltage is normal. Connect the solar panels to the inverter. Close the circuit breaker between the PV input and the inverter. The inverter display should automatically light up and begin charging. Press button '1' on the bottom right corner of the inverter to start the machine. Verify 220V/230V/240V AC output from the inverter.
- AC Input and Output Connection: Install a circuit breaker between the AC input and the inverter. Install another circuit breaker between the inverter's output and your loads. After successful installation, turn on both AC input and output circuit breakers. Connect the inverter to the mains power. Turn off the mains input circuit breaker, then after 2 minutes, turn off the inverter's output circuit breaker. This completes the installation procedure.

Circuit Breaker Specifications:
Appropriate circuit breakers are essential for safety and system protection. Refer to the following guidelines:
- For 3KW Machine:
- Battery to Inverter: 2P100A
- Photovoltaic Input to Inverter: 2P10A
- Utility Input to Inverter: 2P32A
- Inverter Output: 2P15A
- For 3.8KW Machine:
- Battery to Inverter: 2P150A
- Photovoltaic Input to Inverter: 2P20A
- Utility Input to Inverter: 2P40A
- Inverter Output: 2P20A
- For 6.2KW Machine:
- Battery to Inverter: 2P150A
- Photovoltaic Input to Inverter: 2P20A
- Utility Input to Inverter: 2P63A
- Inverter Output: 2P30A

Solar Panel Wiring Method:
When connecting solar panels, consider both series and parallel configurations to optimize voltage and current within the inverter's limits.

3. Operating Instructions
The Sumry Hybrid Solar Inverter offers flexible operating modes to suit various energy needs.
Versatile Working Modes:
Customize the priority of power inputs and outputs with:
- 3 Charging Modes: Only Solar, Solar First, Mains & Solar.
- 2 Output Modes: Solar First, SBU First (Solar-Battery-Utility).
These modes allow for efficient power management and personalized energy consumption based on your preferences and available resources.

Off-Grid Operation:
This inverter is designed for off-grid applications and can supply power to loads even during power failures. It can seamlessly mix solar, battery, and utility power sources.

Monitoring and Communication:
The inverter features a comprehensive LCD display for user-configurable settings and easy-to-access button operations. It supports monitoring and control via the SmartESS App (available on App Store/Google Play) using an optional WiFi module.

The SP series machines have one communication port (COMM port) on the right side. You can choose to communicate via the WiFi module or the battery BMS, but only one method can be active at a time. If using battery BMS communication, ensure the battery uses the PACE or PYLONTECH communication protocol.

Powering Appliances:
The inverter can power a variety of household and office loads, including refrigerators, lamps, televisions, fans, and air conditioning units.

4. Maintenance
The Sumry Hybrid Solar Inverter is designed for durability and includes features to minimize maintenance. Regular checks and proper environmental conditions will ensure optimal performance.
Cooling and Ventilation:
The inverter features intelligent fan speed adjustment for quick evacuation of heat, preventing overheating and ensuring reliable operation. Ensure the inverter is installed in a well-ventilated area, free from obstructions to airflow.

Environmental Protection:
A built-in anti-dusk kit is available (optional) to protect the inverter in harsh environments, reducing the need for frequent cleaning of internal components.
Battery Care:
The smart battery charge design helps optimize battery life. Ensure your chosen battery type is compatible and properly connected as per installation instructions.

5. Troubleshooting
The Sumry Hybrid Solar Inverter is equipped with several protection mechanisms to ensure safe operation. If you encounter issues, these built-in features may be active.
Built-in Protections:
- Overload Protection: The inverter will shut down or reduce output if the connected load exceeds its rated capacity. Reduce the load and restart the inverter.
- High Temperature Protection: If the internal temperature becomes too high, the inverter will protect itself by shutting down. Ensure adequate ventilation and clear any obstructions around the fans.
- Inverter Output Short Circuit Protection: In case of a short circuit at the output, the inverter will immediately cut power to prevent damage. Identify and resolve the short circuit before restarting.
- Automatic Restart: The inverter features an automatic restart function after certain fault conditions are cleared.
- Cold Start Function: Allows the inverter to start directly from the battery without AC input or solar power.

For persistent issues not resolved by these basic checks, please consult the full product manual (if available) or contact customer support.
6. Specifications
Detailed technical specifications for the Sumry SP Series Hybrid Solar Inverter.

| Category | Parameter | Value (SP-6200) |
|---|---|---|
| Rated Power | Rated Power | 6200VA/6200W |
| MAX.PV Array Power | 6000W | |
| INPUT | Voltage | 230VAC |
| Selectable Voltage Range | 170-280VAC (for personal computers); 90-280VAC (for home appliances) | |
| Frequency Range | 50/60HZ (Auto Sensing) | |
| OUTPUT | AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% |
| Surge Power | 14000VA | |
| Transfer Time | 10ms (for personal computers); 20ms (for home appliances) | |
| Wave form | Pure Sine Wave | |
| BATTERY & AC CHARGER | Battery Voltage | 48VDC |
| Floating Charge Voltage | 54VDC | |
| Over Charge Protection | 61VDC | |
| SOLAR CHARGER | MAX.PV Array Power | 6000W |
| MPPT Range @ Operating Voltage | 55-450VDC | |
| Maximum Charging Current | 110A | |
| Maximum Efficiency | 98% | |
| PHYSICAL | Dimension, H*W*D (mm) | 423*300*120 |
| Net Weight (Kgs) | 8.9 | |
| Communication Interface | Two Communication One RS485 port for BMS ports; Another RS485/RS232 for remote monitoring | |
| OPERATING ENVIRONMENT | Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Operating Temperature | -10°C to 55°C | |
| Storage Temperature | -15°C to 60°C |
7. Warranty and Support
The Sumry SP Series Hybrid Solar Inverter comes with a 1-year warranty.
For technical support, troubleshooting assistance beyond the basic checks, or warranty claims, please contact your vendor or the manufacturer directly. Ensure you have your product model and serial number available when seeking support.
8. User Tips
- Battery Compatibility: Always ensure your battery type (Lithium, Gel, LiFePo4, Lead-acid, AGM/Sealed) is correctly configured in the inverter settings for optimal charging and discharge performance.
- Solar Panel Sizing: When connecting solar panels, carefully calculate the total voltage for series connections and total current for parallel connections to stay within the inverter's specified PV input voltage (55-450VDC) and current limits.
- Ventilation is Key: Position the inverter in an area with ample airflow to allow the intelligent fans to dissipate heat effectively, prolonging the unit's lifespan.
- Grounding: Always ensure the PE protective conductor is properly grounded during installation for safety.
- Remote Monitoring: Consider purchasing the optional WiFi module for convenient remote monitoring and control via the SmartESS app, allowing you to track system performance from your smartphone.