DAXTROMN GGH-3.5KW

Contents

DAXTROMN GGH-3.5KW Solar Inverter User Manual

Model: GGH-3.5KW

1. Introduction

The DAXTROMN GGH-3.5KW Solar Inverter is a high-performance, multifunctional inverter/charger designed to provide reliable uninterruptible power support. It integrates the functions of a solar inverter, solar charger, and battery charger. Featuring a pure sine wave output, a built-in MPPT solar charge controller, and comprehensive protection mechanisms, this inverter is suitable for a wide range of applications including residential homes, communication equipment, agricultural setups, and various outdoor power requirements.

DAXTROMN GGH-3.5KW Solar Inverter front view
Figure 1: Front view of the DAXTROMN GGH-3.5KW Solar Inverter.

2. Key Features

  • Pure Sine Wave Output: Delivers clean, stable power, ensuring compatibility and optimal performance for sensitive home appliances and personal computers.
  • Built-in MPPT Solar Controller: Maximizes the efficiency of your solar panels by accurately tracking the Maximum Power Point, even under varying weather conditions.
  • Auto Restart Function: Automatically restarts the inverter once AC power is restored after an outage, ensuring continuous operation without manual intervention.
  • Comprehensive Protection: Incorporates overload, over-temperature, and short-circuit protection to safeguard your equipment and ensure reliable operation under diverse conditions.
  • Smart Battery Charger Design: Optimizes battery performance through efficient charging and discharging cycles, thereby maximizing battery lifespan and reliability.
  • Cold Start Function: Allows the inverter to start and operate effectively even in low-temperature environments, providing power when most needed.
  • High Efficiency: Achieves a conversion efficiency of up to 93.6%.
  • WiFi Supported: Enables convenient remote monitoring of the inverter's status and performance.
  • Adaptive Support: Compatible with lithium batteries, offering flexibility in battery choices.
Key features of the DAXTROMN GGH-3.5KW Solar Inverter including efficiency, protection, WiFi, lithium support, and ease of use
Figure 2: Overview of key features including efficiency, protection, and connectivity options.

3. Product Overview

Before proceeding with installation and operation, familiarize yourself with the inverter's external components and connection points.

Labeled diagram of DAXTROMN GGH-3.5KW Solar Inverter ports and display
Figure 3: Inverter front and bottom panel with labeled components.
  1. LCD display
  2. Status indication LED
  3. Charging indication LED
  4. Fault indication LED
  5. Function keys (for menu navigation and settings)
  6. Power on/off key
  7. R232 communication port
  8. Circuit Breaker
  9. Mains input terminal
  10. Touchdown (Grounding) terminal
  11. Mains output terminal
  12. Battery input/output terminals
  13. Solar input terminals
Internal components diagram of the DAXTROMN GGH-3.5KW Solar Inverter
Figure 4: Internal component layout, highlighting features like the control panel, LED display, BMS, heating plate, and stainless steel shell.

4. Setup and Installation

The DAXTROMN GGH-3.5KW Solar Inverter is designed for wall-mounted installation. Select a location that is well-ventilated, protected from direct sunlight, moisture, and extreme temperatures. Ensure sufficient clearance around the inverter for proper airflow and heat dissipation.

Wall-mounted installation of the multifunctional smart inverter
Figure 5: Example of wall-mounted installation for the inverter.

4.1 System Wiring Diagram

Refer to the following schematic diagram for the overall system integration, showing connections between the inverter, photovoltaic modules, battery bank, utility grid, and household loads.

Inverter working schematic diagram showing connections to PV, battery, grid, and loads
Figure 6: Inverter working schematic diagram. This illustrates the connection of the photovoltaic module, battery, power grid, and household appliances to the inverter.

4.2 Wiring Connections

When making connections, always ensure the inverter is turned off and disconnected from all power sources. Follow local electrical codes and use appropriate wire gauges.

  • Solar Input (13): Connect your photovoltaic (PV) modules to these terminals. Ensure correct polarity (+/-) and that the PV array voltage and current are within the inverter's specified limits.
  • Battery Input/Output (12): Connect your battery bank to these terminals. Observe correct polarity. Ensure the battery voltage matches the inverter's requirements.
  • Mains Input (9): Connect the AC utility grid input here. This connection allows the inverter to charge batteries from the grid and/or pass grid power to loads.
  • Mains Output (11): Connect your household appliances or load distribution panel to this output. This is where the inverter supplies power to your connected devices.
  • Touchdown (10): Ensure proper grounding of the inverter for safety. This is a critical step to prevent electrical hazards.
  • R232 Communication Port (7): This port is used for communication with external devices, such as a computer for monitoring software, or other compatible monitoring systems.

4.3 Dry Contact Signal

A dry contact (rated 3A/250VAC) is available on the rear panel of the inverter. This feature can be utilized to deliver a signal to an external device when the battery voltage reaches a predefined warning level. The table below details the behavior of the dry contact signal based on the unit's status and battery conditions.

Table detailing Dry Contact Signal behavior based on unit status and battery conditions
Figure 7: Dry Contact Signal table. This table explains the conditions under which the dry contact port (NC & C, NO & C) will open or close.
Unit StatusConditionDry contact port:
NC & CNO & C
Power OffUnit is off and no output is powered.CloseOpen
Output is powered from Utility.CloseOpen
Power OnBattery voltage < Low DC warning voltageOpenClose
Program 01 set as UtilityOpenClose
Battery voltage > Setting value in Program 13 or battery charging reaches floating stageCloseOpen
Program 01 is set as SBU or Solar firstBattery voltage < Setting value in Program 12OpenClose
Battery voltage > Setting value in Program 13 or battery charging reaches floating stageCloseOpen

5. Operating Instructions

The inverter features an intuitive LCD display and function keys for monitoring system status and configuring operational parameters. Its pure sine wave output ensures broad compatibility with various electrical appliances.

Diagram explaining pure sine wave output and its benefits
Figure 8: Explanation of pure sine wave output, highlighting its stability and compatibility with sensitive electronics.

5.1 Display and Indicators

  • LCD Display (1): Provides real-time operational status, battery voltage, output power, and other critical system parameters.
  • Status Indication (2): An LED indicator that shows the general operational status of the inverter.
  • Charging Indication (3): An LED indicator that illuminates to show the battery charging status.
  • Fault Indication (4): An LED indicator that signals system errors or warnings, requiring attention.

5.2 Function Keys

The function keys (5) are used to navigate through the LCD menu, view different parameters, and adjust settings as required. The Power On key (6) is used to turn the inverter on or off. Always ensure proper shutdown procedures are followed.

5.3 Operating Modes

The inverter supports both Grid-Tie and Off-Grid operational modes. Specific settings and configurations for these modes can be accessed and adjusted via the function keys and LCD display. For detailed programming instructions and advanced settings, please refer to the comprehensive user manual included with your product.

6. Maintenance

Regular maintenance is crucial for ensuring the longevity, efficiency, and optimal performance of your solar inverter system.

  • Cleaning: Periodically clean the inverter's exterior casing and ensure that all ventilation openings are free from dust, debris, or obstructions. This prevents overheating and maintains efficient heat dissipation. Use a dry, soft cloth for cleaning.
  • Connections Check: At least once a year, inspect all electrical connections (solar input, battery input/output, AC input/output) for tightness and signs of corrosion. Loose connections can lead to increased resistance, overheating, and potential system malfunction.
  • Battery Inspection: If using traditional lead-acid batteries, regularly check electrolyte levels and ensure battery terminals are clean and free of corrosion, following the battery manufacturer's guidelines. For lithium batteries, monitor their health and performance via the inverter's display or any connected monitoring system.
  • Environmental Conditions: Verify that the inverter's operating environment consistently remains within the specified temperature and humidity ranges to prevent damage and ensure stable operation.

7. Troubleshooting

This section provides basic troubleshooting steps for common issues you might encounter. For more complex problems or issues not covered here, it is recommended to consult a qualified technician.

  • No Power Output:
    • Ensure the inverter is properly turned on using the Power On key (6).
    • Verify that all input and output connections are securely fastened.
    • Check the circuit breaker (8) for any trips and reset if necessary.
    • Confirm that the battery voltage is within the inverter's specified operating range.
    • Look for any fault indications on the LCD display (4) and note the error code.
  • Low Solar Charging:
    • Ensure solar panels are clean, free from shading, and optimally positioned for maximum sun exposure.
    • Check all solar input connections (13) for proper wiring and correct polarity.
    • Verify that the PV array voltage is within the MPPT voltage range specified in the technical specifications.
  • Inverter Overheating:
    • Ensure there is adequate ventilation around the inverter and that its cooling fans are operating correctly.
    • Reduce the connected load if the inverter is continuously operating at or near its maximum capacity.
  • Fault Indication (LED 4):
    • If the fault indicator illuminates, refer to the detailed fault codes and their corresponding solutions in the comprehensive user manual for specific error interpretations and corrective actions.

8. Specifications

Detailed technical specifications for the DAXTROMN GGH-3.5KW Solar Inverter are provided below.

CategoryDetail
GeneralBrand: DAXTROMN
Type: Solar Inverter
Model: GGH-3.5KW
Color: Blue-White
System ParametersPhase: 1-Phase
Maximum PV Input Power: 3500W
Rated Output Power: 3500W/3500VA
Maximum Solar Charging Current: 100A
GRID-TIE OPERATIONNominal DC Voltage/Maximum DC Voltage: 360VDC/500VDC
Start-up Voltage/Initial Feeding Voltage: 90VDC/120VDC
MPPT Voltage Range: 120-450VDC
Number of MPPT/Max Input Current: 1/23A
GRID OUTPUT (AC)Nominal Output Voltage: 220/230/240VAC
Output Voltage Range: 195.5-253VAC
Nominal Output Current: 15.7A
Power Factor: >0.99
OFF-GRID OPERATIONAC Input Start-up Voltage/Auto Restart Voltage: 120-140VAC/180VAC
Acceptable Input Voltage Range: 90-280VAC or 170-280VAC
Maximum AC Input Current: 60A
Nominal operating frequency: 50/60Hz
Surge power: 7000VA
BATTERY MODE OUTPUT (AC)Nominal Output Voltage: 220/230/240VAC
Output Waveform: Pure sine wave
Efficiency (DC to AC): 94%
BATTERY & CHARGERNominal DC Voltage: (Battery Dependent)
Maximum Solar Charging Current: 100A
Maximum AC Charging Current: 60A
EnvironmentalOperating Temperature: -10 to 50°C
PhysicalProduct Weight: 10kg
Package Weight: 11kg
Product Size (L x W x H): 49 x 30 x 11 cm
Package Size (L x W x H): 54 x 35 x 18 cm
Package Contents1 x Solar Inverter
1 x User Manual

9. User Tips

To maximize the performance and lifespan of your DAXTROMN GGH-3.5KW Solar Inverter, consider the following user tips:

  • Monitor Performance Regularly: Utilize the LCD display and, if connected, the WiFi monitoring feature to keep track of system status, power generation, and battery health. Consistent monitoring can help identify potential issues early.
  • Optimize Solar Panel Placement: Ensure your solar panels are positioned to receive maximum sun exposure throughout the day and across different seasons. Adjustments may be necessary seasonally for optimal energy harvest.
  • Effective Battery Management: Adhere strictly to the battery manufacturer's guidelines for charging and discharging cycles. Avoid consistently deep discharging your batteries, as this can significantly reduce their lifespan.
  • Prudent Load Management: Always be mindful of the inverter's rated output power (3500W/3500VA) and surge power (7000VA). Avoid connecting loads that exceed these limits to prevent overloading the inverter and potential damage.

10. Warranty and Support

For detailed warranty information, technical support, or any service-related inquiries, please refer to the contact details provided with your original purchase documentation. It is advisable to retain your purchase receipt or invoice as proof of purchase for any potential warranty claims. For further assistance, you may also visit the official DAXTROMN website.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.