VaneAims FXB16-22FSVA

Contents

VaneAims FXB16-22FSVA AC Voltmeter Ammeter User Manual

Model: FXB16-22FSVA | Brand: VaneAims

1. Introduction

The VaneAims FXB16-22FSVA is a compact 22mm LED digital dual-display meter designed to simultaneously measure and display AC voltage and current. This device is ideal for monitoring electrical parameters in various AC mains supply applications. It features a clear digital readout and is available in multiple display colors.

Multiple VaneAims AC Voltmeter Ammeters in various colors with a current transformer
Overview of the VaneAims FXB16-22FSVA AC Voltmeter Ammeter and its current transformer.

2. Safety Information

  • This product is designed for use with AC 50-60Hz mains supply only.
  • DO NOT use with: generators, motors, engines, silicon-controlled transformers, frequency converters, square-wave outputs, or inverter outputs (including modified sine wave circuits). Using with incompatible power sources may damage the device and pose a safety risk.
  • Always ensure power is disconnected before installation or maintenance to prevent electric shock.
  • Installation should be performed by qualified personnel familiar with electrical wiring and safety standards.
  • Ensure all connections are secure and properly insulated.
  • Keep the device away from moisture and extreme temperatures.

3. Product Overview

The FXB16-22FSVA meter consists of a main display unit and an external current transformer (CT). Key features include:

  • LED Digital Display: Clear, bright display for voltage and current readings.
  • Rotary Fasteners: For secure panel mounting.
  • Fire Retardant Material: Enhanced safety.
  • Superior Quality: Designed for industrial electrical applications.

The meter is available in various display colors:

Close-up of five different colored LED displays: Green, Red, Blue, Yellow, White
Available display colors: Green, Red, Blue, Yellow, White.
Detailed view of the meter's components including rubber seal ring, fixing nut, and screw terminals
Detailed design showing the rubber seal ring, fixing nut, and screw terminals.

4. Specifications

ParameterValue
Brand NameVaneAims
Model NumberFXB16-22FSVA
Display TypeLED Digital (Voltage, Current)
Measuring Voltage RangeAC 24V ~ 500V
Measuring Current RangeAC 0 ~ 100A
Power Supply Frequency50-60Hz
Mounting Size22mm diameter panel cutout
Relative Measurement Error±1A / ±5V
Minimum Test Current (for sensitivity)2.5A
Dimensions (approx.)Display Face: 30.6mm (W) x 28.3mm (H)
Total Depth: 48.2mm
Mounting Depth: 20.5mm
Battery IncludedNo
OriginMainland China
Diagram showing product dimensions: 30.6mm width, 28.3mm display height, 48.2mm total depth, 20.5mm mounting depth
Product dimensions for installation planning.

5. Setup and Installation

Follow these steps for safe and proper installation:

  1. Prepare Mounting Hole: Create a 22mm diameter circular cutout in your control panel or enclosure.
  2. Mount the Meter: Insert the meter into the prepared hole from the front. Secure it from the rear using the provided fixing nut. Ensure the rubber seal ring is correctly positioned for a snug fit.
  3. Wiring the Voltage Input (Power Supply):
    • Identify the two main screw terminals on the back of the meter (these are typically larger or clearly marked for voltage input).
    • Connect the AC 24-500V mains supply wires to these terminals. These connections also power the meter's display.
    • Ensure the power source is within the specified AC 24-500V, 50-60Hz range.
  4. Wiring the Current Transformer (CT):
    • Locate the two smaller terminals on the back of the meter, typically connected to a small white connector.
    • Connect the two wires from the current transformer (CT) to these terminals. The CT wires are usually red and black.
    • Pass only ONE of the load wires (the wire whose current you wish to measure) through the center hole of the current transformer. Do not pass both live and neutral wires through the CT, as this will result in a zero current reading.
    • The CT is not polarity sensitive for current measurement, but ensure a single conductor passes through it.
  5. Verify Connections: Double-check all wiring for correctness and security before applying power.
Back view of the meter showing screw terminals for power and current transformer connections
Rear view of the meter showing connection points.
Meter displaying 230V and 00.0A, with the current transformer connected and a wire passing through it
Example of a connected meter displaying voltage and current.

6. Operating Instructions

Once properly installed and powered, the meter will automatically display the measured AC voltage and current. No further configuration is required for basic operation.

  • The top display shows the AC voltage in Volts (V).
  • The bottom display shows the AC current in Amperes (A).
  • Readings are updated in real-time.

7. Maintenance

  • Cleaning: Wipe the display and casing with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Connection Checks: Periodically inspect all electrical connections to ensure they remain tight and free from corrosion.
  • No User-Serviceable Parts: Do not attempt to open or repair the meter. Doing so will void any potential warranty and may pose a safety hazard.

8. Troubleshooting

ProblemPossible CauseSolution
No display / Meter not turning onNo power supply, incorrect voltage input, loose connections.Check AC 24-500V power connections to the meter's main terminals. Ensure voltage is within range.
Incorrect voltage readingVoltage input outside specified range, measurement error.Verify the actual line voltage. Note the relative error of ±5V.
Current reading is 0.0A or insensitiveCurrent below 2.5A, incorrect CT wiring, both live and neutral wires passed through CT.Ensure the load current is above 2.5A for accurate readings. Verify CT wires are correctly connected to the meter. Ensure only ONE load wire passes through the CT. Note the relative error of ±1A.
Meter damaged after connectionUsed with incompatible power sources (e.g., generator, inverter).Refer to the Safety Information section. This product is strictly for AC 50-60Hz mains supply.

9. User Tips

  • For accurate current measurements, ensure the current absorption of your load is greater than 2.5 Amperes. Readings below this threshold may be insensitive or inaccurate.
  • This meter is commonly used in main electrical panels to monitor overall consumption in Amperes and Volts.
  • The current measurement using the CT is typically bidirectional in terms of magnitude, meaning it will display the current flow regardless of direction in an AC circuit, but it does not indicate the phase or direction.

10. Warranty and Support

For any issues, questions, or technical support regarding your VaneAims FXB16-22FSVA meter, please contact the seller or manufacturer directly. Keep your purchase records handy for any warranty claims.

Please note that improper installation or use with incompatible power sources, as outlined in the Safety Information, may void any applicable warranty.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.