SUSWE SU900

SUSWE SU900 Series Variable Frequency Drive

User Instruction Manual

1. Introduction

The SUSWE SU900 series Variable Frequency Drive (VFD) is a high-power motor speed controller and frequency converter designed for various industrial applications. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SU900 VFD.

The SU900 VFD supports vector control and offers multiple protection functions, ensuring device protection, energy saving, high efficiency, and stability. It is suitable for a wide range of motors and applications, including woodworking machinery, food machinery, textile machinery, plastic machinery, CNC machine printing machinery, and general automation requiring precise motor control.

SUSWE SU900 VFD with power and voltage options
Figure 1: SUSWE SU900 VFD with available power (30KW-45KW) and voltage configurations (1P 220V Input to 3P 380V/220V Output, 3P 380V Input to 3P 380V Output).

2. Safety Information

Before installation, operation, or maintenance, carefully read and understand all instructions in this manual. Failure to follow safety precautions may result in serious injury or equipment damage.

  • Ensure the VFD is installed by qualified personnel only.
  • Always disconnect power before performing any wiring or maintenance.
  • Verify correct voltage and phase connections as per the wiring diagrams.
  • Do not touch internal components when power is applied or shortly after power-off, as residual voltage may be present.
  • Ensure proper grounding of the VFD and connected motor.
  • Operate the VFD within its specified environmental conditions (temperature, humidity).
CE, FC, RoHS certifications for the VFD
Figure 2: The SU900 VFD is certified with CE, FC, and RoHS standards, indicating compliance with safety and environmental regulations.

3. Specifications

The SUSWE SU900 series VFD is available in various power ratings. Key specifications are detailed below. For specific model parameters, refer to the tables and diagrams provided.

General Product Information

ParameterValue
NameGeneral purpose inverter
Power Specifications0.75 - 45KW
Input Voltage220V / 380V
Rated Current1.5 - 320A (varies by model)
Input Frequency50/60HZ
Protection LevelIP20
Temperature Range-20 ~ +60°C
Cooling ModeSelf-cooling fan
Product Protection6 great protections
Table of general product information for the VFD
Figure 3: General product information and specifications for the SU900 series inverter.

Model-Specific Parameters (SU900-30R0G3, 37R0G3, 45R0G3)

ParameterSU900-30R0G3SU900-37R0G3SU900-45R0G3
Rated Current60A76A91A
Adapted Motor30KW 40Hp37KW 50Hp45KW 60Hp
Input VoltageThree phase 380V
Output VoltageThree phase 380V
External Dimensions (mm)360 x 225 x 231.7
Gross Weight10Kg
Specifications for SU900-30R0G3 model
Figure 4: Detailed parameters for the SU900-30R0G3 model.
Specifications for SU900-37R0G3 model
Figure 5: Detailed parameters for the SU900-37R0G3 model.
Specifications for SU900-45R0G3 model
Figure 6: Detailed parameters for the SU900-45R0G3 model.

External Unit Dimensions

The SU900 series VFDs come in various external unit sizes (C1 to C5) depending on the model and power supply. Refer to the diagrams below for general dimensions. Always consult the specific product manual for exact dimensions of your model.

C1 external unit dimensions for single-phase 220V and three-phase 380V models
Figure 7: C1 external unit dimensions, suitable for SU800-0R75G2, SU800-1R5G2, SU800-2R2G2 (single-phase 220V) and SU800-0R75G3, SU900-1R5G3, SU900-2R2G3 (three-phase 380V).
C2 external unit dimensions for single-phase 220V and three-phase 380V models
Figure 8: C2 external unit dimensions, suitable for SU800-5R5G2, SU800-7R5G2 (single-phase 220V) and S0800-4R0G3, SU800-5R5G3, SU800-7R5G3, SU900-4R0G3, SU900-5R5G3, SU900-7R5G3 (three-phase 380V).
C3 external unit dimensions for three-phase 380V models
Figure 9: C3 external unit dimensions, suitable for SU900-7R5G3, SU900-11R0G3, SU900-15R0G3 (three-phase 380V).
C4 external unit dimensions for three-phase 380V models
Figure 10: C4 external unit dimensions, suitable for SU900-18R5G3, SU900-22R0G3 (three-phase 380V).
C5 external unit dimensions for three-phase 380V models
Figure 11: C5 external unit dimensions, suitable for SU900-18R5G3, SU900-22R0G3 (three-phase 380V).

4. Installation

Proper installation is crucial for the safe and reliable operation of the VFD. Pay attention to safety matters to prevent dangerous occurrences and improper operation.

Wiring Instructions

The wiring is designed to be simple and convenient. Ensure all connections are secure and follow local electrical codes.

Terminal MarksNameInstruction
R, S, T / L, NPower supply input terminalsConnect three-phase 380V or single-phase 220Vac power supply
P+, PBBrake electric resistance connection terminalsConnect brake electric resistance
U, V, WFrequency converter output terminalsConnect three-phase motor
Grounding terminalsGrounding terminals
Table of main circuit terminal instructions for the VFD
Figure 12: Main circuit terminal instructions for connecting power, braking resistance, and motor.

Simplified Wiring Diagrams

Below are simplified wiring diagrams for 220V and 380V systems. Always ensure the ground wire is properly connected.

Simplified 220V and 380V wiring diagrams for the VFD
Figure 13: Simplified wiring diagrams. The 220V diagram shows Output L N connected to power supply and Output U V W connected to motor. The 380V diagram shows R S T for power input and Output U V W connected to motor. Both diagrams emphasize proper grounding.

Detailed Control Circuit Wiring (3-Phase 380V Example)

The control circuit wiring for all 800/900 series inverters is similar. The following diagram illustrates the three-phase 380V converter wiring, indicating both main loop and control loop terminals. For detailed control circuit configurations, refer to the comprehensive product manual.

Detailed 3-phase 380V control circuit wiring diagram for the VFD
Figure 14: Detailed wiring method for a 3-phase 380V frequency converter control circuit, showing connections for input, braking resistance, motor, and various control signals (e.g., multifunctional inputs X1-X4, analog output A01, open collector output Y1, high speed pulse output HDO, relay outputs K1A/K1B/K1C, RS485 communication).

5. Operation

The SU900 VFD features a user-friendly control panel for easy operation and monitoring.

Control Panel Overview

The man-machine interactive key panel allows simultaneous monitoring of two groups of operating data, including speed, frequency, current, and voltage. An external extension network cable can be used to adjust working conditions more flexibly.

Control panel layout with labeled keys and display area
Figure 15: Control panel with labeled components: Display area, Speed control knob, Displacement key, Run key, Programming Key, Stop/reset key, Increment Key, Confirm key, Decrement key, and Multi-function keys.
Detachable smart panel connected via network cable
Figure 16: The detachable smart panel allows for remote control and flexible adjustment of working conditions using an external network cable connector.

Basic Operation

  1. Power On: Ensure all wiring is correct and secure before applying power.
  2. Parameter Setting: Use the Programming Key and Increment/Decrement Keys to navigate menus and adjust parameters. The Confirm Key (ENTER) saves settings.
  3. Speed Control: Adjust the Speed Control Knob to set the desired output frequency/motor speed.
  4. Run/Stop: Press the Run Key to start the motor and the Stop/Reset Key to stop it.
  5. Monitoring: The Display Area shows real-time operating data such as frequency and current.

6. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your VFD.

Internal Components and Construction

The inverter features well-known brand components and a robust internal structure for stability and durability.

Internal view of the VFD circuit board with components
Figure 17: Internal view of the VFD, showcasing well-known brand components and a clearly visible, stable, and durable internal structure designed for a longer service life.

Welding Process

The circuit board utilizes an industrial SMT welding process, ensuring smooth and reliable solder paste application for high reliability and gloss of welding.

Close-up of the VFD circuit board welding process
Figure 18: Close-up view of the circuit board, highlighting the welding process which ensures reliability and quality of connections.

Anti-EMC Power Supply

The VFD incorporates an industrial anti-EMC power supply with a low-loss high-frequency transformer, overload protection, and a wide voltage input function. It features an independent bridge wall power supply scheme with self-check for abnormal power supply functions.

Internal view of the VFD's anti-EMC power supply components
Figure 19: Detail of the industrial anti-EMC power supply, showing the high-frequency transformer and other components designed for robust power management.

Three Anti-Paint Process

The VFD's circuit boards undergo a fully automatic double-sided coating process using imported polyurethane cool treatment. This enhances the stability of the inverter in harsh environments.

Close-up of the VFD circuit board with anti-paint coating
Figure 20: Close-up of the circuit board illustrating the three anti-paint process, which provides protection against harsh environmental conditions.

Efficient Heat Dissipation

The VFD is equipped with DC fans and an aluminum alloy radiator for quick and efficient heat dissipation. Intelligent start and stop functions ensure optimal cooling speed.

DC fan for efficient heat dissipation in the VFD
Figure 21: View of the DC fan and aluminum alloy radiator, designed for fast and intelligent heat dissipation.

7. Troubleshooting

This section provides general guidance for common issues. For detailed error codes and specific troubleshooting steps, please refer to the comprehensive product manual or contact technical support.

  • No Power/Display: Check input power connections, fuses, and ensure the VFD is correctly wired to the power supply.
  • Motor Not Running: Verify motor connections (U, V, W), check VFD parameters for correct motor type and control mode, and ensure the Run command is active.
  • Overcurrent/Overvoltage Fault: Check motor load, acceleration/deceleration times, and input voltage stability. Ensure braking resistance is correctly installed if used.
  • Overheat Fault: Ensure adequate ventilation around the VFD. Check if cooling fans are operating correctly and are free from obstructions.
  • Communication Error (RS485): Verify RS485 wiring, communication parameters (baud rate, parity), and ensure the external device is functioning correctly.

8. User Tips

Based on common user inquiries, here are some helpful tips for using your SU900 VFD:

  • Phase Conversion Capability: The SU900 VFD is versatile and can handle various phase conversions. It supports:
    • Single-phase 220V input to three-phase 380V output.
    • Single-phase 220V input to three-phase 220V output.
    • Three-phase 380V input to three-phase 380V output.
    Ensure you select the correct model and configure it according to your specific power supply and motor requirements.
  • Parameter Customization: Take advantage of the programming keys to fine-tune parameters for your specific application. This can optimize motor performance, energy efficiency, and protection.
  • External Control: Utilize the detachable smart panel and RS485 communication for remote control and integration into automation systems, offering greater flexibility in operation.

9. Warranty and Support

The SUSWE SU900 Variable Frequency Drive comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal operating conditions. Please retain your proof of purchase for warranty claims.

For technical support, troubleshooting assistance beyond this manual, or warranty inquiries, please contact your vendor or the manufacturer's customer service. Provide your product model number (SU900) and a detailed description of the issue for efficient support.