PowMr POW-48140A

Contents

PowMr 140A MPPT Solar Charge Controller

Model: POW-48140A

User Manual

1. Introduction

1.1 Purpose

This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.

1.2 Features

  • Configurable battery charging current based on applications via LCD setting
  • Over temperature protection
  • Smart battery charger design for optimized battery performance
  • Cold start function

1.3 Basic System Architecture

This is a solar charger. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current. The following illustration shows a basic application for this solar charger:

Diagram showing a house with solar panels, an MPPT controller, a battery system, and an inverter, illustrating a home power system.
Figure 1: Hybrid Power System Overview

The system typically includes PV modules, an MPPT Controller, a Battery System, and an Inverter to power your home.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION - Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect DC terminals. Please refer to INSTALLATION section of this manual for the details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. NEVER cause DC input short circuited.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this charger back to local dealer or service center for maintenance.

3. Product Overview

The PowMr 140A MPPT Solar Charge Controller is designed for efficient solar energy management. Key features include:

  • 140A Max Charge Current
  • Supports 48V Battery Voltage
  • 60-450VDC PV Array Voltage Range
  • 6500W Max. PV Array Power
Image highlighting the key specifications of the 140A MPPT Solar Charge Controller: 6500W Max PV Power, 500V Max PV VOC, 140A Max PV Current.
Key Specifications of the MPPT Charge Controller

The unit features a large LCD screen for displaying PV voltage, charging current, charging power, battery voltage, and main CPU Version. The maximum charging current can be set from 10A to 140A.

Large LCD screen of the solar charge controller showing input voltage, battery voltage, and charging status.
Large LCD Screen Display

The controller supports various battery types including Vented, Sealed, Gel, NiCd, and Lithium batteries (LiFePO4, Li(NiCoMn)O2).

Diagram showing compatibility with various battery types: GEL, FLD (Flooded), AGM, Li (LiFePO4), and SLA (Sealed Lead-acid) batteries.
Compatible Battery Types

The product's physical dimensions are 435x310x180mm and it weighs 6.5kg.

Front view of the PowMr Solar Charge Controller.
Product Front View
Side view of the PowMr Solar Charge Controller.
Product Side View
Bottom view of the PowMr Solar Charge Controller showing connection ports.
Product Bottom View
Angled view of the PowMr Solar Charge Controller.
Product Angled View

4. Installation

4.1 Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:

  • The unit x 1
  • User manual x 1

4.2 Preparation

Before connecting all wirings, please take off the bottom cover by removing two screws.

4.3 Mounting the Unit

Consider the following points before selecting where to install:

  1. Do not mount the charger on flammable construction materials.
  2. Mount on a solid surface.
  3. Install this charger at eye level in order to allow the LCD display to be read at all times.
  4. For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
  5. The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  6. The recommended installation position is to be adhered to the wall vertically.
  7. Be sure to keep other objects and surfaces to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two screws. It's recommended to use M6 screws.

4.4 Wiring Guide Video

Video: POW-48140A Solar Charge Controller Wiring Guide. This video demonstrates mounting the controller, removing the port cover, connecting the battery, connecting the PV array, and powering on the system.

4.5 Battery Connection

Recommended battery cable size:

ModelWire SizeCable(mm²)Torque value (max)
24V/140A1 x 2AWG252 Nm
48V/140A

CAUTION

  • For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and charger. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in above table as required fuse or breaker size.

WARNING

  • All wiring must be performed by a qualified personnel.
  • It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable.

Please follow below steps to implement battery connection:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into battery connectors of charger and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity at both the battery and the charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

WARNING

  • Installation must be performed with care due to high battery voltage in series.

CAUTION

  • Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative.

4.6 PV Connection

Recommended PV cable size:

ModelWire SizeCable(mm²)Torque value (max)
24V/140A1 x 12AWG41.2 Nm
48V/140A

CAUTION

  • Before connecting to PV modules, please install separately a DC circuit breaker between charger and PV modules.

WARNING

  • It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size.

PV Module Selection:

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of charger.
  2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
Solar panel specifications table showing Max. PV Array Power, Max. PV Array Open Circuit Voltage, PV Array MPPT Voltage Range, and PV Wire Size. Also includes PV Module Selection guidelines.
Solar Panel Specifications and PV Module Selection Guidelines

Take a 250Wp PV module as an example. After considering the above two parameters, the recommended module configurations are listed in the table within the image above.

PV Module Wire Connection:

Please follow below steps to implement PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
Detailed wiring diagram for installing the solar charge controller, showing connections for battery, inverter, and solar panels.
How to Install the System: Wiring Diagram

4.7 Final Assembly

After connecting all wirings, please put the bottom cover back by screwing two screws.

5. Operation

5.1 Operation and Display Panel

The operation and display panel is on the front of the charger. It includes two indicators, four function keys, and an LCD display, indicating the operating status and PV power information.

LED IndicatorMessages
CHG (Green Solid On)Battery is fully charged
CHG (Green Flashing)Battery is charging.
FAULT (Red Solid On)Fault occurs in the charger
FAULT (Red Flashing)Warning condition occurs in the charger
Function KeysDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

5.2 LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press the "DOWN" button to select setting programs. Then, press the "ENTER" button to confirm the selection or press the "ENTER" button a second time to exit.

Setting Programs:

No.DescriptionSelectable Option
00Exit setting modeEscape (default): 00 GOE, One-button restore setting options: 00 GOK
02Maximum charging current60A (default): 02 60. Setting range is 10~140A, increment of each click is 10A.
05Battery typeAGM: 05 AGn, Flooded: 05 FLd, USE: 05 USE. If "User-Defined" is selected, battery charge voltage can be set up in program 26, 27 and 29.
07Auto restart when over temperature occursRestart disable (default): 07 ttd, Restart enable: 07 tYE
26Bulk charging voltage (C.V voltage)24V default setting: 28.2V (C 26 28.2), 48V default setting: 56.4V (C 26 56.4)
27Floating charging voltageIf self-defined is selected in program 5, this program can be set up. Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. (24V default: FLY 27 270, 48V default: FLY 27 540)
30Battery equalizationBattery equalization: 30 EEN, Battery equalization disable (default): 30 EdS. If "Flooded" or "User-Defined" is selected in program 05, this program can be set up.
31Battery equalization voltageSetting range is from 25.0V to 29.5V for 24V model and 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. (24V default: EV 31 29.2, 48V default: EV 31 58.4)
33Battery equalized time60min (default): 33 60. Setting range is from 5min to 900min. Increment of each click is 5min.
34Battery equalized timeout120min (default): 34 120
35Equalization interval30days (default): 35 30d. Setting range is from 0 to 90 days. Increment of each click is 1 day.
36Equalization activated immediatelyEnable: 36 AEN, Disable (default): 36 AdS. If equalization function is enabled in program 30, this program can be set up. If "Enable" is selected, it's to activate battery equalization immediately and LCD main page will show "E9". If "Disable" is selected, it will cancel equalization function until next activated equalization time arrives based on program 35 setting. At this time, "E9" will not be shown in LCD main page.
81Year set81 00 to 81 99
82Month set82 01 to 82 12
83Day set83 01 to 83 31
84Hour set84 00 to 84 24
85Minute set85 00 to 85 60
86Clean Energy86 ENABLE, 86 DISABLE

5.3 Display Information

The LCD display information will be switched in turns by pressing the "UP" or "DOWN" key. The selectable information includes PV voltage, charging current, charging power, battery voltage, and main CPU Version.

The display shows various parameters in different states (Standby, Charging) including:

  • Version number
  • PV voltage
  • PV current
  • PV temperature/PV power
  • Charge current/Battery voltage
  • Charge power
  • Daily power generation
  • Monthly power generation
  • Gross generation
  • Date and Time
Diagram illustrating the three-stage charging process: Boost Charge, Bulk Charge, Float Charge, and Equalization Charge, designed to prolong battery lifespan.
Three-Stage Charging Mode

6. Maintenance

6.1 Clearance and Maintenance for Anti-Dust Kit

Every charger is already installed with an anti-dust kit from the factory. The charger will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust out of your charger and increases product reliability in harsh environments.

To clean and maintain the anti-dust kit:

  1. Loosen the screw in a counterclockwise direction on the top of the charger.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the charger.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

7. Troubleshooting

7.1 Fault Reference Code

Fault CodeFault EventIcon on
01Fan is locked when charger is off.01 ERROR
02Over temperature02 ERROR
03Battery voltage is too high03 ERROR
08Bus voltage is too high08 ERROR
09Bus soft start failed09 ERROR
51Over current or surge51 ERROR
52Bus voltage is too low52 ERROR
57Current sensor failed57 ERROR
59PV voltage is over limitation59 ERROR

7.2 Warning Indicator

Warning CodeWarning EventAudible AlarmIcon flashing
E9Battery equalizationNoneE9®
bPBattery is not connectedNonebP®

7.3 General Troubleshooting

ProblemLCD/LED/BuzzerExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer will be active for 3 seconds and then complete off.The battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low. (<1.4V/Cell)
2. Internal fuse tripped.
1. Contact repair center for replacing the fuse.
2. Re-charge battery.
3. Replace battery.
Fault code 02Internal temperature of charger component is over 70°C.Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Red LED is on.Battery is over-charged.The battery voltage is too high.Return to repair center.
Check if spec and quantity of batteries meet requirements.
Fault code 01Fan faultReplace the fan.
Fault code 52Bus voltage is too low.Restart the unit, if the error happens again, please return to repair center.

8. Specifications

8.1 MPPT Solar Charging Mode

MODEL24V48V
Max. PV Array Power4200W6500W
Nominal PV Voltage180Vdc280Vdc
PV Array MPPT Voltage Range60Vdc~450Vdc
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current140Amp

8.2 Physical Specifications

ParameterValue
Dimension (L x W x H)435 × 310 × 180 mm
Weight6.5 kg

9. User Tips

  • Ensure proper battery voltage selection (24V or 48V) during setup to match your system requirements.
  • Verify if smart device features are desired, as this model supports them for enhanced control and monitoring.
  • Regularly clean the anti-dust kit (monthly) for optimal performance and to prolong the lifespan of the controller.
  • Always double-check wiring polarity for both battery and PV connections to prevent damage.

10. Frequently Asked Questions (FAQ)

Q: Is this a smart device?
A: Yes, the PowMr 140A MPPT Solar Charge Controller is a smart device.
Q: What battery voltages does it support?
A: It supports both 24V and 48V battery systems.
Q: What is the maximum PV input voltage?
A: The maximum PV array open circuit voltage (Voc) is 500Vdc.
Q: What is the maximum PV array power?
A: For a 24V system, the maximum PV array power is 4200W. For a 48V system, it is 6500W.
Q: What types of batteries are compatible with this controller?
A: The controller is compatible with Vented, Sealed, Gel, NiCd, and Lithium batteries (including LiFePO4 and Li(NiCoMn)O2).

11. Warranty and Support

For technical support, service, or warranty inquiries, please contact:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
Tel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

A PDF version of this user manual is available for download at: User manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.