1. Introduction
1.1 Purpose
This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2 Features
- Configurable battery charging current based on applications via LCD setting
- Over temperature protection
- Smart battery charger design for optimized battery performance
- Cold start function
1.3 Basic System Architecture
This is a solar charger. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current. The following illustration shows a basic application for this solar charger:

The system typically includes PV modules, an MPPT Controller, a Battery System, and an Inverter to power your home.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect DC terminals. Please refer to INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- NEVER cause DC input short circuited.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this charger back to local dealer or service center for maintenance.
3. Product Overview
The PowMr 140A MPPT Solar Charge Controller is designed for efficient solar energy management. Key features include:
- 140A Max Charge Current
- Supports 48V Battery Voltage
- 60-450VDC PV Array Voltage Range
- 6500W Max. PV Array Power

The unit features a large LCD screen for displaying PV voltage, charging current, charging power, battery voltage, and main CPU Version. The maximum charging current can be set from 10A to 140A.

The controller supports various battery types including Vented, Sealed, Gel, NiCd, and Lithium batteries (LiFePO4, Li(NiCoMn)O2).

The product's physical dimensions are 435x310x180mm and it weighs 6.5kg.




4. Installation
4.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:
- The unit x 1
- User manual x 1
4.2 Preparation
Before connecting all wirings, please take off the bottom cover by removing two screws.
4.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the charger on flammable construction materials.
- Mount on a solid surface.
- Install this charger at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. It's recommended to use M6 screws.
4.4 Wiring Guide Video
4.5 Battery Connection
Recommended battery cable size:
| Model | Wire Size | Cable(mm²) | Torque value (max) |
|---|---|---|---|
| 24V/140A | 1 x 2AWG | 25 | 2 Nm |
| 48V/140A |
CAUTION
- For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and charger. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in above table as required fuse or breaker size.
WARNING
- All wiring must be performed by a qualified personnel.
- It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable.
Please follow below steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert the battery wires flatly into battery connectors of charger and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity at both the battery and the charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
WARNING
- Installation must be performed with care due to high battery voltage in series.
CAUTION
- Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative.
4.6 PV Connection
Recommended PV cable size:
| Model | Wire Size | Cable(mm²) | Torque value (max) |
|---|---|---|---|
| 24V/140A | 1 x 12AWG | 4 | 1.2 Nm |
| 48V/140A |
CAUTION
- Before connecting to PV modules, please install separately a DC circuit breaker between charger and PV modules.
WARNING
- It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size.
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of charger.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.

Take a 250Wp PV module as an example. After considering the above two parameters, the recommended module configurations are listed in the table within the image above.
PV Module Wire Connection:
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.

4.7 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws.
5. Operation
5.1 Operation and Display Panel
The operation and display panel is on the front of the charger. It includes two indicators, four function keys, and an LCD display, indicating the operating status and PV power information.
| LED Indicator | Messages |
|---|---|
| CHG (Green Solid On) | Battery is fully charged |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the charger |
| FAULT (Red Flashing) | Warning condition occurs in the charger |
| Function Keys | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.2 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press the "DOWN" button to select setting programs. Then, press the "ENTER" button to confirm the selection or press the "ENTER" button a second time to exit.
Setting Programs:
| No. | Description | Selectable Option |
|---|---|---|
| 00 | Exit setting mode | Escape (default): 00 GOE, One-button restore setting options: 00 GOK |
| 02 | Maximum charging current | 60A (default): 02 60. Setting range is 10~140A, increment of each click is 10A. |
| 05 | Battery type | AGM: 05 AGn, Flooded: 05 FLd, USE: 05 USE. If "User-Defined" is selected, battery charge voltage can be set up in program 26, 27 and 29. |
| 07 | Auto restart when over temperature occurs | Restart disable (default): 07 ttd, Restart enable: 07 tYE |
| 26 | Bulk charging voltage (C.V voltage) | 24V default setting: 28.2V (C 26 28.2), 48V default setting: 56.4V (C 26 56.4) |
| 27 | Floating charging voltage | If self-defined is selected in program 5, this program can be set up. Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. (24V default: FLY 27 270, 48V default: FLY 27 540) |
| 30 | Battery equalization | Battery equalization: 30 EEN, Battery equalization disable (default): 30 EdS. If "Flooded" or "User-Defined" is selected in program 05, this program can be set up. |
| 31 | Battery equalization voltage | Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. (24V default: EV 31 29.2, 48V default: EV 31 58.4) |
| 33 | Battery equalized time | 60min (default): 33 60. Setting range is from 5min to 900min. Increment of each click is 5min. |
| 34 | Battery equalized timeout | 120min (default): 34 120 |
| 35 | Equalization interval | 30days (default): 35 30d. Setting range is from 0 to 90 days. Increment of each click is 1 day. |
| 36 | Equalization activated immediately | Enable: 36 AEN, Disable (default): 36 AdS. If equalization function is enabled in program 30, this program can be set up. If "Enable" is selected, it's to activate battery equalization immediately and LCD main page will show "E9". If "Disable" is selected, it will cancel equalization function until next activated equalization time arrives based on program 35 setting. At this time, "E9" will not be shown in LCD main page. |
| 81 | Year set | 81 00 to 81 99 |
| 82 | Month set | 82 01 to 82 12 |
| 83 | Day set | 83 01 to 83 31 |
| 84 | Hour set | 84 00 to 84 24 |
| 85 | Minute set | 85 00 to 85 60 |
| 86 | Clean Energy | 86 ENABLE, 86 DISABLE |
5.3 Display Information
The LCD display information will be switched in turns by pressing the "UP" or "DOWN" key. The selectable information includes PV voltage, charging current, charging power, battery voltage, and main CPU Version.
The display shows various parameters in different states (Standby, Charging) including:
- Version number
- PV voltage
- PV current
- PV temperature/PV power
- Charge current/Battery voltage
- Charge power
- Daily power generation
- Monthly power generation
- Gross generation
- Date and Time

6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit
Every charger is already installed with an anti-dust kit from the factory. The charger will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust out of your charger and increases product reliability in harsh environments.
To clean and maintain the anti-dust kit:
- Loosen the screw in a counterclockwise direction on the top of the charger.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the charger.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
7. Troubleshooting
7.1 Fault Reference Code
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when charger is off. | 01 ERROR |
| 02 | Over temperature | 02 ERROR |
| 03 | Battery voltage is too high | 03 ERROR |
| 08 | Bus voltage is too high | 08 ERROR |
| 09 | Bus soft start failed | 09 ERROR |
| 51 | Over current or surge | 51 ERROR |
| 52 | Bus voltage is too low | 52 ERROR |
| 57 | Current sensor failed | 57 ERROR |
| 59 | PV voltage is over limitation | 59 ERROR |
7.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| E9 | Battery equalization | None | E9® |
| bP | Battery is not connected | None | bP® |
7.3 General Troubleshooting
| Problem | LCD/LED/Buzzer | Explanation / Possible Cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Fault code 02 | Internal temperature of charger component is over 70°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Red LED is on. | Battery is over-charged. | The battery voltage is too high. | Return to repair center. Check if spec and quantity of batteries meet requirements. |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 52 | Bus voltage is too low. | Restart the unit, if the error happens again, please return to repair center. |
8. Specifications
8.1 MPPT Solar Charging Mode
| MODEL | 24V | 48V |
|---|---|---|
| Max. PV Array Power | 4200W | 6500W |
| Nominal PV Voltage | 180Vdc | 280Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current | 140Amp | |
8.2 Physical Specifications
| Parameter | Value |
|---|---|
| Dimension (L x W x H) | 435 × 310 × 180 mm |
| Weight | 6.5 kg |
9. User Tips
- Ensure proper battery voltage selection (24V or 48V) during setup to match your system requirements.
- Verify if smart device features are desired, as this model supports them for enhanced control and monitoring.
- Regularly clean the anti-dust kit (monthly) for optimal performance and to prolong the lifespan of the controller.
- Always double-check wiring polarity for both battery and PV connections to prevent damage.
10. Frequently Asked Questions (FAQ)
- Q: Is this a smart device?
- A: Yes, the PowMr 140A MPPT Solar Charge Controller is a smart device.
- Q: What battery voltages does it support?
- A: It supports both 24V and 48V battery systems.
- Q: What is the maximum PV input voltage?
- A: The maximum PV array open circuit voltage (Voc) is 500Vdc.
- Q: What is the maximum PV array power?
- A: For a 24V system, the maximum PV array power is 4200W. For a 48V system, it is 6500W.
- Q: What types of batteries are compatible with this controller?
- A: The controller is compatible with Vented, Sealed, Gel, NiCd, and Lithium batteries (including LiFePO4 and Li(NiCoMn)O2).
11. Warranty and Support
For technical support, service, or warranty inquiries, please contact:
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTDTel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
A PDF version of this user manual is available for download at: User manual (PDF)