1. Introduction
The JUNCTEK KM-F series multifunctional voltage and current meter is an advanced coulomb meter designed for precise monitoring of various battery parameters. It accurately measures voltage, current, power, charging and discharging capacity, and watt-hours. This device is compatible with multiple battery types, including Lead-acid, Ternary lithium, and Lithium iron phosphate batteries, making it suitable for a wide range of applications such as RVs, e-bikes, and home power backup systems.
Key features include a 2.4-inch high-definition color screen for comprehensive data display, automatic identification of charging and discharging currents, and real-time battery capacity monitoring. The KM-F series also offers multiple protection functions such as overvoltage, undervoltage, overcurrent, overpower, over-temperature, and timed protection. With built-in WiFi and Bluetooth connectivity, you can remotely monitor and control the device via a mobile app, view real-time voltage and current curves, and export data. The firmware is freely updatable for life, ensuring your device stays current with the latest features.
2. Safety Requirements
Please read and understand all safety precautions before operating the meter to prevent personal injury or damage to the device. Adhere to the following guidelines:
- Observe All Terminal Ratings: To avoid fire or shock hazards, always observe all ratings and markers on the meter. Refer to this manual for detailed information before making connections.
- Use Proper Over-voltage Protection: Ensure that the product is protected from over-voltage events (e.g., lightning strikes) to prevent electric shock.
- Do Not Operate Without Covers: Never operate the meter with its covers or panels removed.
- Do Not Insert Anything Into Air Outlets: Avoid inserting any objects into the air outlets to prevent damage to the meter.
- Avoid Circuit or Wire Exposure: Do not touch exposed junctions and components when the unit is powered on.
- Do Not Operate With Suspected Failures: If you suspect any damage, have the meter inspected by JUNCTEK authorized personnel before further use. All maintenance, adjustments, or replacements must be performed by JUNCTEK authorized personnel.
- Provide Adequate Ventilation: Inadequate ventilation can lead to increased internal temperature and potential damage. Ensure the meter is well-ventilated and regularly inspect the air outlet and fan.
- Do Not Operate in Wet Conditions: To prevent short circuits or electric shock, never operate the meter in a humid environment.
- Do Not Operate in an Explosive Atmosphere: Never operate the meter in an explosive atmosphere to avoid personal injury or damage.
- Keep Meter Surfaces Clean and Dry: Maintain clean and dry surfaces to prevent dust or moisture from affecting performance.
- Prevent Electrostatic Impact: Operate the meter in an electrostatic discharge protective environment. Always ground internal and external conductors of cables to release static before connections.
- Handle with Caution: Handle the device with care during transportation to prevent damage to keys, knobs, interfaces, and other parts.
Important Notices:
- Do not exceed the specified voltage and current range to prevent damage.
- Ensure correct polarity; positive and negative poles cannot be reversed.
- The meter's shell is fragile; avoid hitting it or exposing it to chemicals to prevent corrosion.
- Store the meter in a dry environment at temperatures between -25°C and 50°C.
- Do not attempt to disassemble the meter, as this will void the warranty. Repairs must be done by designated service centers.
- The display screen is fragile; avoid touching or bumping it. Clean with a soft cloth if dirty.
- Avoid violent movement to prevent internal circuit damage. Contact the supplier if the meter malfunctions.
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
3. Product Components and Shipping List
The KM-F series Coulomb Meter package typically includes the following items. Please check the contents upon receipt and contact your JUNCTEK sales representative if anything is damaged or missing.
- Display Module: 1 pc
- Sampler (50A, 100A, 400A, or 600A depending on model): 1 pc
- 5m Communication Cable: 1 pc
- 1m Red Positive Electrode Wire: 1 pc
- Quick Guide: 1 pc
- Temperature Sensor: 1 pc (for measurement module)
- 4P Connection Cable: 1 pc (for measurement module)
- 3P Connection Cable: 1 pc (for measurement module)
- 3P Power Socket: 1 pc (for measurement module)
4. Specifications
General Specifications:
| Feature | KM105F | KM110F | KM140F | KM160F |
|---|---|---|---|---|
| Sampling Method | Shunt | |||
| Voltage Measurement Range | 10-100V | |||
| Voltage Resolution | 0.01V | |||
| Current Measurement Range | 0-50A | 0-100A | 0-400A | 0-600A |
| Current Resolution | 0.001A | 0.01A | ||
| Capacity Display Range | 0%-100% | |||
| Power Measurement Range | 0-5KW | 0-10KW | 0-40KW | 0-60KW |
| Power Resolution | 0.0001W | |||
| Ampere-Hour Measurement Range | 0-9999.9Ah | |||
| Capacity Resolution | 0.001Ah | |||
| Bluetooth Communication Distance | Up to 10 meters (No obstacle) | |||
| WiFi Connection Distance | Maximum 10 meters in an open area | |||
| Remote Connection Distance | Global | |||
| Voltage Accuracy | ±5‰+0.02V | |||
| Current Accuracy | ±2‰+0.002A | ±1%+0.1A | ||
| Sampling Rate | 5 times per second | |||
| Display Power Consumption | 0.9W | |||
Dimensions:
- Display Module: 100mm (W) x 67.8mm (H) x 30.7mm (D)
- Display Module Inlay Hole Size: 85.1mm x 58.1mm
- 50A Sampler: 67.4mm (W) x 45mm (H) x 14.5mm (D)
- 100A Sampler: 100mm (W) x 46mm (H) x 35.1mm (D)
- 400A Sampler: 152mm (W) x 63mm (H) x 45.1mm (D)
- 600A Sampler: 152mm (W) x 87.5mm (H) x 45.1mm (D)
5. Setup: Wiring Method
Proper wiring is crucial for the safe and accurate operation of your Coulomb Meter. Please follow these instructions carefully.
5.1 Self-Powered Wiring Method (10-120V Battery)
This method is suitable if the battery voltage is between 10-120V.
- Set the power selection switch to "2W".
- Connect the positive pole of the battery to the "Vsns" port of the power supply interface. A 13-16AWG wire is acceptable.
- Connect the negative pole of the battery to the screw marked "BATT-" on the sampler.
- Connect the negative pole of the charger and the negative pole of the load to the screw marked "LOAD-" on the sampler.
- It is recommended to use a copper nose for secure wiring.
During charging, the current symbol will be green and show "charging", with increasing capacity. During discharge, the current symbol will be light blue and show "discharging", with decreasing capacity.
5.2 External Power Supply Connection Method (0-120V Measurement)
This method is used when an external power supply is needed for the measurement module.
- Set the power supply selection switch to "3W".
- Connect the positive pole of the external power supply to the "VEXT" interface and the negative pole to the "GND" interface.
- Connect the positive pole of the battery to the measurement module's "Vsns" interface.
- Connect the negative pole of the battery to the "BATT-" screw on the sampler.
- Connect the negative pole of the charger and load to the "LOAD-" screw on the sampler.
- Ensure correct polarity for all connections.
5.3 External Power Relay Wiring Method (Optional)
If you wish to use a relay for protection functions (e.g., overvoltage, overcurrent), you will need an external relay with its own power supply.
- Connect the relay's control ports to the "OUT" and "VEXT" of the measurement module's Output Control.
- Connect the positive pole of the external power supply for the relay to "VEXT" and the negative pole to "GND".
- Connect the negative pole of the battery to the "BATT-" screw on the sampler.
- Connect the negative pole of the charger and load to the "LOAD-" screw on the sampler.
- Ensure all polarities are correct.
When the relay is activated, an indicator light will turn on. During charging, the current symbol is green; during discharging, it is sky blue.
6. Operating Instructions
6.1 Display Module Interface
The 2.4-inch TFT color LCD screen displays various parameters and settings. The display has several indicators and buttons:
- LCD Screen: Shows current functions, settings, and parameters.
- SET Button: Briefly press to switch to settings; long-press on main interface to adjust communication address.
- UP (▲) Button: Changes parameters in settings; selects system settings; long-press on main interface to save zero-point current.
- DOWN (▼) Button: Changes parameters in settings; selects system settings; long-press on main interface to turn off/on the display screen.
- OK Button: Briefly press on main interface to control relay (if installed); long-press to lock/unlock buttons. Confirms selections in settings.
- Communication Port: Used to connect to the measurement module.
6.2 System Settings
Access system settings by pressing the SET button. Use the UP (▲) and DOWN (▼) buttons to navigate and OK to select/confirm.
- Date and Time: Adjust year, month, day, hour, minute, and second. Synchronizes with phone via app.
- Language Selection: Choose between Chinese and English.
- Sound Option: Turn buzzer sound on or off.
- Temperature Unit: Select Fahrenheit or Celsius.
- Preset Battery Capacity: Set the total battery capacity (e.g., 0000.0Ah).
- Remaining Capacity Percentage: Manually set the current battery capacity percentage (0-100%).
- Screen Brightness: Adjust daytime (6:00-22:00) and nighttime (22:00-6:00) screen brightness (0-100%).
- Screen-off Time: Set the display to turn off after a period of inactivity (1-60 seconds) or remain always on (0).
- Bluetooth Pairing Password: Default is 0000. Can be modified via display, not app. Resets to default after power cycle.
- Data Record: Enable/disable data recording. When full, data needs to be cleared.
- Delay Protection Setting: Set a delay (0-99s) before protection functions activate. Requires a separate relay.
- Zero Current Memory: Confirm zero-point current state.
- Relay Mode: Set relay to normally open or normally closed (requires separate relay).
- Address Matching: Set communication address (P01-P99) for multiple measurement modules.
- Low Battery Warning: Set a percentage (0-100%) for low capacity reminder.
- Overvoltage Protection (OVP): Set voltage threshold (0.00-120.00V). Requires a separate relay.
- Undervoltage Protection (LVP): Set voltage threshold (0.00-120.00V). Requires a separate relay.
- Charging Overcurrent Protection (NCP): Set current threshold (0-100A/400A/600A). Requires a separate relay.
- Discharge Overcurrent Protection (OCP): Set current threshold (0-100A/400A/600A). Requires a separate relay.
- Over Power Protection (OPP): Set power threshold (0-12000.00W/48000.00W/72000.00W). Requires a separate relay.
- Over Temperature Protection (OTP): Set temperature threshold (-20-120°C/-4-248°F). Requires a separate relay.
- Low Temperature Protection (LTP): Set temperature threshold (-20-120°C/-4-248°F). Requires a separate relay.
- Recovery Time: Set delay (0-99s) for protection status to clear.
- Display Host Mode: Enable/disable display screen communication.
- Factory Reset: Resets all settings to factory defaults.
6.3 Mobile App Control
The KM-F series supports mobile app control via Bluetooth and WiFi, offering remote monitoring and configuration. The app is compatible with Android 5.0+ and iOS 9.0+ systems.
App Download:
- Android: Download from http://68.168.132.244/KH/KH-F.apk.
- iOS: Search for "KH-F Series" in the Apple App Store or use link: https://apps.apple.com/cn/app/kh-f/id1665076881.
During installation, grant necessary permissions like location services. It is recommended to update to the latest app and firmware versions for the best experience.
App Features:
- Real-time Monitoring: View voltage, current, power, capacity, and estimated time.
- Comprehensive Settings: Adjust all meter parameters, including interface style, data analysis, and protection settings.
- Data Export: Generate Excel files of historical voltage and current data.
- Firmware Upgrade: Update device firmware through the app.
6.4 Communication Protocol Control (Advanced Users)
For advanced users, JUNCTEK provides a communication protocol for secondary development. The control instructions are command-line based, with a communication rate of 115200. Commands are sent from a PC, parsed by the meter, and results are returned. The protocol supports 'W' (write) commands for setting parameters and 'R' (read) commands for retrieving parameters.
For detailed information on the communication protocol, please refer to the 'KH-F Series Communication Protocol' document available on the JUNCTEK official website.
7. Maintenance
- Cleaning: Keep the meter's surfaces clean and dry to prevent dust and moisture from affecting performance. Use a soft, dry cloth for cleaning.
- Handling: Handle the device with care to avoid physical damage. Do not expose it to harsh chemicals.
- Storage: Store the meter in a dry environment within the specified temperature range (-25°C to 50°C).
- Ventilation: Ensure adequate ventilation around the device to prevent overheating. Regularly check and clear any obstructions from air outlets.
8. Troubleshooting
If you encounter any issues, refer to the following common problems and solutions:
- Screen Remains Black / No Display:
- Check power connections and the connection between the display and measurement modules.
- Restart the meter.
- If the issue persists, contact JUNCTEK support.
- Screen Too Dark:
- Adjust the LCD screen brightness in system settings (Day/Night screen brightness).
- Display Module Connected, but Data/Time Not Updated:
- Check if "Display Host mode" is turned off in system settings. Enable it if necessary.
- Communication Interruption (Red 'x' on Display):
- Check the communication cable for damage or loose connections.
- Verify that the communication address of the measurement module matches the display module.
- If a firmware upgrade was interrupted, re-upgrade the firmware.
- WiFi Connectivity Issues:
- Ensure your router is compatible (some users reported issues with specific Chinese Huawei routers, but generally works).
- Check app permissions for WiFi access.
- If connectivity is lost after an app update, try reinstalling the app or checking for a newer app version.
- Inaccurate Battery Constant Charge Analysis:
- Perform calibration if needed.
9. User Tips
- The KM-F series is highly effective for monitoring home power backup systems, providing precise measurements.
- Installation and initial setup are generally straightforward.
- The mobile app is user-friendly and does not require an account for basic operation.
- The device offers excellent control for charging and discharging LiFePO4 batteries via Bluetooth and WiFi.
- The WiFi connection is generally stable and reliable, often connecting well with the Junce Home app.
- The robust shunt with M10 ports ensures secure connections, especially for higher current models like the 600A.
- Battery capacity is highly customizable, settable from 1-9999Ah.
- For remote monitoring, the WiFi feature is very convenient.
- If you experience issues with the app's appearance or minor bugs, ensure you have the latest version installed.
10. Warranty and Support
For any questions, issues, or support needs regarding your JUNCTEK KM-F Series Coulomb Meter, please contact JUNCTEK directly:
- Email: junce@junteks.com
- Website: www.junteks.com
Additional resources, including detailed user manuals (PDF) and operation demonstration videos, can be found on the official JUNCTEK website. The user manual PDF can be referenced at this link.
11. Statement of Compliance
This product complies with the following certifications:
- CE
- FCC
- pse