1. Introduction
The LCTC LC908 is a versatile PID Digital Temperature Controller designed for industrial applications. It features a segment LCD display with high brightness backlight, offering a wide viewing angle for clear monitoring. This controller supports universal input types (TC/RTD, analog) and provides multiple output options including SSR, Relay, 0-10V, and 4-20mA. Advanced functionalities like RS485 Modbus communication and dual alarm groups enhance its adaptability for various control systems.

Figure 1: Front view of the LCTC LC908 PID Temperature Controller, highlighting its 0-10V analog input, SSR/Relay/0-10V/4-20mA output, 2 group alarms, 96x96mm panel size, and RS485 Modbus function.
2. Specifications
| Feature | Specification |
|---|---|
| Brand Name | LCTC |
| Model Number | LC908 |
| Theory | Temperature Controller |
| Display Type | DIGITAL (Segment LCD with high brightness backlight) |
| Display Size | 1.9 Inches & Under |
| Power Type | Charger (85-265VAC 50-60Hz) |
| Max Measuring Temperature | 49°C & Under |
| Style | Embedded |
| Use | Industrial |
| Certification | CE |
| Origin | Mainland China |
| Input Type | TC (K, E, J, T, B, S, Wu3_Re25, N, R), RTD (Pt100), Analog (DC 0-5V, 1-5V, 0-10V, 2-10V, DC 4-20mA, 0-20mA) |
| Output Type | SSR, RELAY, 4-20mA, 0-10V |
| Alarm | 1 Alarm or 2 Alarms (Max 2 sets) |
| Communication | RS485 Modbus (optional) |
| Transmission | PV: 4-20mA, PV: 0-10VDC (optional) |
| Accuracy | ±(Max±0.2%F.S. or ±1) <±1 digit |
| Sampling Cycle | 0.25 Sec |
| PV Bias | -199 ~ 199°C or -199.9~199.9°C |
| Display Unit | °C or °F |
| Environment | 0-50℃, No condensation, Humidity: <85% |
| Battery Included | No |
| High-concerned chemical | None |
Dimensions

Figure 2: Available panel sizes for the LC908 series, including 48x48mm, 48x96mm, 72x72mm, and 96x96mm.
3. Setup and Wiring
Proper installation and wiring are crucial for the safe and effective operation of your LC908 PID Temperature Controller. Always ensure power is disconnected before performing any wiring.
Wiring Diagrams
The LC908 controller comes in various sizes, each with a specific wiring configuration. Refer to the diagrams below and the connection stickers on the side of your controller for precise wiring in your application.

Figure 3: General connection diagrams for different sizes of the LC908 controller. Note: Always refer to the specific stickers on your device for accurate wiring.

Figure 4: A close-up of the wiring diagram found on the side of the LC908 unit. This diagram provides specific terminal assignments for power, inputs, outputs, and communication.
Terminal Descriptions (General)
- Power Supply: Connect 85-265VAC 50-60Hz to the designated power terminals.
- Input (INP1): Universal input for TC/RTD or analog signals (0-10V, 4-20mA).
- Output (OP1): Control output, configurable as SSR, Relay, 0-10V, or 4-20mA.
- Alarms (AL1, AL2): Up to two alarm outputs available.
- RS485: Terminals for Modbus communication (A+, B-).
- INP2: Used for remote SV or position feedback.
Important Note:
Commonly used product input types for temperature controllers include TC/RTD input, 0-10V input, and 4-20mA input. The output type of common temperature controllers is typically SSR output, Relay output, 0-10V output, or 4-20mA output, often with RS485 communication and a default of 1 alarm, with a maximum of 2 sets of alarms. If you require a product with special functions such as Fuzzy logic, Autotuning, Transmission, Remote control, LED BAR display, Motor valve control, Heat & Cool functionality, Programmable control, or Ramp&Sock functions, please contact customer service for customization. If no special features are specified during ordering, the standard product without these advanced functions will be provided.
4. Operating Instructions
The LC908 controller features a clear segment LCD display and intuitive buttons for operation.
Display Overview

Figure 5: The LC908 display showing Process Value (PV), Set Value (SV), Output 1 (OP1) indicator, and alarm indicators.
- PV (Process Value): Displays the current measured temperature or process variable.
- SV (Set Value): Displays the desired target temperature or setpoint.
- OP1: Indicates the status of the primary control output.
- Alarm Indicators: Lights up when an alarm condition is met.
Button Functions
- SET: Used to enter parameter setting mode and confirm selections.
- A/M: Toggles between Automatic and Manual control modes.
- F1 (Up Arrow): Increases values or navigates through menus.
- F2 (Down Arrow): Decreases values or navigates through menus.
- F3 (Left Arrow): Shifts cursor position during parameter entry or navigates back.
Basic Operation
- Power On: Connect the controller to the specified power supply (85-265VAC). The display will light up.
- Set Value (SV) Adjustment: Press the SET button briefly to enter the SV adjustment mode. Use the F1 (Up) and F2 (Down) arrows to change the SV. Press SET again to confirm.
- Parameter Configuration: To access advanced parameters, press and hold the SET button for several seconds until the parameter menu appears. Use F1/F2 to navigate and F3 to select or shift digits. Press SET to confirm changes and exit.
- Manual/Automatic Control: Press the A/M button to switch between automatic PID control and manual output control. In manual mode, you can directly adjust the output percentage.
Functional Demonstration
Video 1: Demonstration of the LC908 PID controller's functionality, showing it regulating a light bulb's intensity based on a setpoint, with the output waveform displayed on an oscilloscope.
5. Advanced Features
The LC908 offers several advanced features for complex control requirements:
- Double PID Heating/Cooling: Allows for precise control in applications requiring both heating and cooling cycles.
- Programmer Control (32 Segment): Enables the creation of complex temperature profiles with up to 32 programmable segments.
- Soft Start Function: Gradually increases output to prevent sudden surges and protect equipment.
- Digit Input Function: Provides additional digital input capabilities.
- 3 Wires Motor Valve PID Control: Specifically designed for controlling 3-wire motor valves with PID algorithms.
- RS485 Modbus Communication: Facilitates integration into larger control systems for remote monitoring and control.
- Transmission Output (Optional): Provides re-transmission of Process Value (PV) as 4-20mA or 0-10VDC signals for external devices.
6. Maintenance
The LCTC LC908 PID Temperature Controller is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:
- Cleaning: Keep the front panel and display clean using a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Environmental Conditions: Ensure the operating environment adheres to the specified temperature (0-50°C) and humidity (<85%, non-condensing) limits.
- Connections: Periodically check all wiring connections for tightness and signs of corrosion. Ensure proper insulation.
- Ventilation: Ensure adequate airflow around the unit, especially if it's embedded, to prevent overheating.
7. Troubleshooting
If you encounter issues with your LC908 controller, consider the following common troubleshooting steps:
- No Power: Verify the power supply connections and ensure the voltage is within the 85-265VAC range. Check for blown fuses in the power circuit.
- Incorrect Readings (PV):
- Check the input sensor wiring for correct polarity and secure connections.
- Ensure the input type configured in the controller matches the sensor being used (e.g., K-type thermocouple, Pt100 RTD, 0-10V analog).
- Inspect the sensor for damage or proper placement in the process.
- No Output Control:
- Verify the output wiring is correct for your chosen output type (SSR, Relay, 0-10V, 4-20mA).
- Check if the controller is in manual mode; switch to automatic mode if PID control is desired.
- Ensure the Set Value (SV) and Process Value (PV) are within the expected range for control action.
- Check alarm settings if they are configured to inhibit output.
- Communication Issues (RS485):
- Verify RS485 wiring (A+, B-) and termination resistors if applicable.
- Check Modbus address and baud rate settings in the controller and your master device.
- Ensure no other devices are conflicting on the RS485 bus.
- Display Errors: If the display shows unusual characters or is blank, power cycle the unit. If the problem persists, contact technical support.
8. User Tips
- Initial Setup: Before connecting to your main process, perform a bench test with a simple sensor and load to familiarize yourself with the controller's basic functions and parameter settings.
- Parameter Backup: For complex configurations, it's advisable to record your parameter settings. This can save time during re-configuration or if settings are accidentally changed.
- Sensor Matching: Always ensure the input type configured in the controller precisely matches the type of sensor you are using (e.g., K-type thermocouple, Pt100 RTD). Mismatched sensor types will result in inaccurate readings.
- Autotuning: Utilize the autotuning function (if available and applicable to your model) for optimal PID performance. This feature helps the controller learn the characteristics of your system and set appropriate PID parameters.
- Safety First: Always disconnect power before making or changing any wiring connections to prevent electrical shock or damage to the unit.
9. Warranty and Support
For warranty information, technical assistance, or service inquiries, please contact your vendor or the manufacturer directly. Ensure you have your product model number (LC908) and any relevant purchase details available when seeking support.