Introduction
The Morayelec ME201W is an advanced ultrasonic liquid level sensor designed for remote monitoring of water tanks. Utilizing Tuya Smart technology, it provides reliable distance detection, easy installation, and high durability. This device allows users to monitor liquid levels, receive alarm notifications, and optionally control a pump directly from their smartphone, offering a convenient and efficient solution for various applications.

Figure 1: Morayelec ME201W Liquid Level Monitor components and app interface.
Package Contents
- ME201W Liquid Level Sensor
- Power Adapter (EU/US/UK/AU type, depending on selection)
- Installation Mark (3M adhesive)
- Instruction Manual (this document)

Figure 2: ME201W sensor and available power adapter types.
Setup Instructions
1. Physical Installation
- Identify the center of the tank where the sensor will be installed.
- Paste the provided 3M installation mark at the chosen location.
- Drill a hole with a diameter of 55mm precisely in the middle of the marked area.
- Carefully place the ME201W sensor over the drilled hole, ensuring it is centered and the ultrasonic probe is unobstructed.
- Secure the sensor using self-tapping screws.

Figure 3: Step-by-step physical installation of the sensor.
Installation Considerations:
- The tank's inner wall should be smooth for optimal reflection.
- Avoid installing the sensor directly above pipelines or protruding outlets to prevent interference.
- Ensure no floating objects or boards are present in the sensor's reflection area.
- The sensor must be held perpendicular to the liquid surface.
- Install the sensor away from the water inlet to avoid pseudo-echoes caused by incoming water.
- Do not install the sensor too close to the tank bulkhead, as this can cause strong pseudo-echoes.

Figure 4: Ultrasonic beam characteristics and critical installation notes.

Figure 5: Correct sensor orientation and placement to avoid interference.
2. App Installation & Pairing
- First, connect the AC/DC power adapter to the sensor and then plug it into a power outlet.
- Scan the QR code in the product packaging or search for “TUYA Smart APP” or “Smart Life APP” in your mobile device's app store and download it.
- **Network Reset**: Press and hold the button on the sensor for 5 seconds. The LED light will flash rapidly. Release the button to initiate the network reset. The device will then attempt to connect to the network automatically.
- **Connecting Sensors to APP**: Ensure your phone's Wi-Fi and Bluetooth are turned on. Open the Tuya Smart or Smart Life app, navigate to the 'Add Device' section, and follow the on-screen prompts to connect your ME201W Level Sensor. You will need to enter your Wi-Fi network name and password.

Figure 6: Initial app pairing steps.

Figure 7: Completing app pairing and accessing the monitoring interface.
Operating Instructions
1. Monitoring Liquid Levels
Once connected, the app will display the current liquid level ratio and depth in meters. Historical data can be viewed by day, month, or year. The app provides real-time updates on the liquid level status.
Video 1: Demonstration of liquid level monitoring and alarm states on the app.
2. Alarm Notifications
The sensor supports configurable alarms for high and low liquid levels. When the liquid level exceeds or falls below the set thresholds, the app will trigger an alarm and send a message notification to your smartphone.

Figure 8: App interface displaying different alarm states.
3. Product Settings
Within the app, you can configure various settings for your sensor:
- **Installation Height**: Set this parameter to the distance from the sensor's mounting point to the bottom of the tank. This is crucial for accurate depth readings.
- **Pump Working Mode**: The default pump working mode is 'Refilling'. This can be adjusted if you have an external pump connected.
- **Max Level Alarm**: Set the maximum liquid level threshold to trigger a 'Full Alarm'.
- **Min Level Alarm**: Set the minimum liquid level threshold to trigger a 'Lower Alarm'.
4. Optional Pump Control
The ME201W can be integrated with an external pump system for automated liquid level management. This typically involves connecting the sensor to a solid-state relay which then controls the pump. The app allows you to configure the pump's operation based on liquid levels (e.g., start refilling when low, stop when full).

Figure 9: Setup for optional pump control.
5. Multi-Tank Monitoring
The Tuya Smart or Smart Life app supports monitoring multiple ME201W sensors simultaneously. This allows you to track liquid levels in several tanks from a single interface.

Figure 10: Multi-tank monitoring capability.
Maintenance
- **Cleaning**: Periodically inspect the sensor's surface for dirt, dust, or debris. Gently wipe it clean with a soft, damp cloth. Avoid using abrasive cleaners or solvents.
- **Power Supply**: Ensure the power adapter is securely connected and free from damage.
- **Firmware Updates**: Check the app regularly for any available firmware updates for the sensor to ensure optimal performance and access to new features.
- **Environmental Conditions**: While the sensor has IP65 protection, extreme weather conditions or prolonged exposure to harsh chemicals may affect its lifespan.
Troubleshooting
- **Sensor Not Connecting to App**:
- Ensure the sensor is powered on and the LED is flashing rapidly during network reset.
- Verify your phone's Wi-Fi and Bluetooth are enabled.
- Check that your Wi-Fi network is 2.4G, as the sensor operates on this frequency.
- Ensure the Wi-Fi password entered in the app is correct.
- Try moving the sensor closer to your Wi-Fi router during the initial pairing process.
- **Inaccurate Liquid Level Readings**:
- Recheck the 'Installation Height' setting in the app to ensure it matches the physical distance from the sensor to the tank bottom.
- Inspect the sensor's probe area for any obstructions (dirt, debris, floating objects).
- Verify that the sensor is installed perpendicularly to the liquid surface and away from water inlets or bulkheads (refer to Figure 5).
- Ensure the inner walls of the tank are smooth in the reflection area.
- **No Alarm Notifications**:
- Check your app's notification settings and your phone's system notification settings to ensure they are enabled for the Tuya Smart/Smart Life app.
- Verify that the 'Max Level Alarm' and 'Min Level Alarm' thresholds are correctly set in the app.
- Ensure the sensor has a stable Wi-Fi connection.
- **Pump Control Not Working**:
- Confirm that the external pump and solid-state relay are correctly wired and powered.
- Check the pump control settings within the app to ensure the automation rules are properly configured.
Specifications
| Feature | Specification |
|---|---|
| Brand Name | morayelec |
| Model Number | ME201W |
| DIY Supplies | Plumbing |
| Origin | Mainland China |
| Certification | CE |
| WiFi Frequency | 2.4G |
| Input Voltage | 100-240V AC to 5V DC |
| Max Level Detection | 4m |
| Detection Range | 0.1m - 4m |
| Supply Voltage | 5V DC |
| Protection Rating | IP65 |
| DC Connector | 5.5*2.5mm |
| Battery Included | No |
| High-concerned chemical | None |
| Package Length | 17 cm |
| Package Width | 16 cm |
| Package Height | 6 cm |
| Package Weight | 0.4 kg |
User Tips
- For optimal performance, ensure the sensor has a strong and stable 2.4G Wi-Fi signal. This contributes to fast connection speeds and wide coverage.
- Regularly check the app for monitoring reminders and ensure your alarm thresholds are set appropriately for your tank's usage patterns.
- Proper installation, especially ensuring the sensor is perpendicular to the liquid and free from obstructions, is key to accurate water level measurements.
Warranty and Support
For warranty information and technical support, please refer to the official Morayelec website or contact your retailer. Keep your purchase receipt as proof of purchase.