1. Introduction
The Morayelec ME201WC is an advanced ultrasonic liquid level monitor designed for precise and remote monitoring of liquid levels in various tanks, such as water or oil tanks. This device integrates with the Tuya SmartLife app, offering real-time data, alarm notifications, and optional pump control functionalities via WiFi. Its high-precision ultrasonic sensor ensures accurate readings, making it an ideal solution for home automation and efficient water management.
2. Safety Information
- Ensure the power supply matches the device specifications (100-240VAC to DC 5V).
- Do not expose the device to extreme temperatures outside its operating range (-20°C to 70°C).
- Avoid installing the sensor in direct contact with the liquid inlet to prevent pseudo-echoes.
- Ensure the sensor is held perpendicular to the liquid surface during installation.
- Keep the sensor installation away from bulkheads to avoid strong pseudo-echoes.
- The device is IP65 protected, meaning it is dust-tight and protected against low-pressure water jets. However, avoid submerging it.
3. Specifications
| Feature | Specification |
|---|---|
| Model Number | ME201WC |
| Type | Digital Fluid Level Monitor |
| DIY Supplies | Plumbing |
| Application | Water / Oil Tank |
| Usage | Home Automation System |
| Power Supply | 100-240VAC to DC 5V (Sensor power supply: ≤100mA@ 5V DC) |
| Measuring Range | 0.1m ~ 4.0m |
| Accuracy | ±0.02m |
| Operating Temperatures | -20°C ~ 70°C |
| Protection Rating | IP65 |
| Network Mode | 2.4G WiFi (max 50m no obstacle between sensor and router) |
| Operation System | Android, iOS APP |
| APP | Tuya SmartLife |
| Relay (for pump control) | 40A@480V AC |
| Certification | CE |
For detailed specifications and other models (ME201W, ME201WSP, ME201Z, ME201WCS), please refer to the comprehensive table below:

Figure 3.1: Model Comparison Table
4. Setup Guide
4.1. Physical Installation
Proper physical installation is crucial for accurate readings. Follow these steps and precautions:
- Remove the release paper from the gasket and attach the gasket to the center of the tank where the hole will be drilled.
- Drill a hole in the middle of the tank with a diameter greater than 55mm.
- Place the sensor over the gasket, ensuring it is aligned with the screw holes and unobstructed.
- Fasten the sensor with self-tapping screws.
Important Notes for Installation:
- If the mounting surface is curved, fix the sensor with screws just enough to prevent stress. If data is abnormal, loosen the screws.
- Hold the sensor perpendicular to the liquid surface.
- Install the sensor away from the water inlet to avoid pseudo-echoes.
- The sensor installation cannot be close to the bulkhead, as this will cause strong pseudo-echoes.
- Ensure there are no obstacles in the reflective area of the sensor.
- For circular water tanks, ensure the inner wall is smooth (no rough surfaces).
- Avoid installing near pipelines, protruding outlets, floating balls, or boards within the sensor's beam angle.

Figure 4.1: Sensor Installation Guidelines

Figure 4.2: Detailed Installation Steps
4.2. Wiring (for Pump Control)
The ME201WC model supports pump control via a solid-state relay. Refer to the electrical definition and connection diagrams for proper wiring.
- Connect the AC/DC adaptor to power the sensor.
- The sensor connects to the solid-state relay (CDG1-1DA/40A AC-12-40A/480VAC).
- The solid-state relay then controls the water pump.

Figure 4.3: Overall System Wiring Diagram

Figure 4.4: Simplified Pump Control Wiring
4.3. App Installation and Network Connection
- First, power on the AC/DC ADAPTOR, then power on the sensor. The sensor's LED light will flash.
- Scan the QR code provided in the manual or search for "TUYA Smart APP" or "Smart Life APP" in your mobile device's app store to download and install the application.
- Network Reset: If needed, press and hold the button on the sensor for 5 seconds. The LED light will flash rapidly. Release the button to reset the network. The device will then attempt to connect to the network automatically.
- Connecting Sensors to APP: Turn on the WiFi and Bluetooth on your phone. Open the app and follow the on-screen instructions to add the device.
Important Notes for App Connection:
- The WiFi frequency must be 2.4GHz, not 5GHz.
- When adding a device, ensure both the sensor and your phone are connected to the same 2.4GHz WiFi network.
- After successful setup, the indicator light must be steady. If the phone cannot find the device or fails to connect, repeat step 3 (network reset) and try again.

Figure 4.5: App Setup and Device Pairing
5. Operating Instructions
5.1. App Interface Overview
Once connected, the Tuya SmartLife app will display real-time liquid level information:
- Liquid Level Ratio: Percentage of liquid in the tank.
- Liquid Level Depth: Actual depth of the liquid in meters.
- Liquid Level Status: Indicates 'Normal', 'Lower alarm', or 'Full alarm'.
- Supply Voltage: Current voltage of the sensor.
- Liquid Level Depth History: View historical data by Day, Month, or Year.

Figure 5.1: App Liquid Level Monitoring Interface
5.2. Monitoring Liquid Levels
The app provides continuous monitoring. You can check the liquid level ratio, depth, and status at any time. The historical data feature allows you to track changes over time, helping you understand consumption patterns or tank refill cycles.
5.3. Alarm Settings
Configure custom alarms to be notified when liquid levels reach critical thresholds:
- Installation Height (A): Set the distance from the sensor to the tank bottom.
- Liquid Maximum Depth (B): Set the maximum height of liquid in the tank.
- Set Max: Define the high-level alarm threshold (e.g., 80%). This is based on the actual liquid level value (C) relative to the maximum depth (B), calculated as (C/B * 100%).
- Set Min: Define the low-level alarm threshold (e.g., 20%).
Example: If Installation height A=4m, Liquid maximum depth B=3m, and actual liquid level C=2m. If Set Max=60% and Set Min=20%, the current level status (C/B*100% = 2/3*100% = 67%) would trigger a 'Full alarm' if the threshold was set lower than 67%.
5.4. Pump Control (Optional)
The ME201WC offers automated pump control based on liquid levels:
- Auto Pump Control:
- On-Auto (Default): The pump is automatically controlled by the 'Full' and 'Low' alarm values.
- Off-Manual: The pump is not controlled automatically by alarm values.
- Pump Working Mode: The default mode is 'Supply' (Refilling Water).
- Pump Switch:
- On-Start: Manually turns the pump on.
- Off-Stop (Default): Manually turns the pump off.
Note:
- When 'Auto Pump Control' is enabled, the 'Pump Switch' status will automatically update to reflect the automated operation.
- On-Supply (Default): Full alarm turns the pump OFF, low alarm turns the pump ON.
- Off-Drainage: Low alarm turns the pump OFF, full alarm turns the pump ON.

Figure 5.2: Pump Control Functionality
Video 5.1: Demonstration of Liquid Level Monitoring and Alarm States in App
6. Maintenance
- Cleaning: Periodically clean the sensor surface to ensure accurate readings. Use a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Inspection: Regularly check the sensor's physical installation to ensure it remains secure and correctly positioned.
- Wiring: Inspect wiring connections for any signs of wear or damage. Ensure all connections are tight and secure.
- Software Updates: Keep the Tuya SmartLife app updated to the latest version for optimal performance and new features.
7. Troubleshooting
- Device not found during pairing / Connection failure:
- Ensure your WiFi network is 2.4GHz (5GHz is not supported).
- Make sure both your phone and the sensor are connected to the same 2.4GHz WiFi network.
- Perform a network reset on the sensor by pressing and holding the button for 5 seconds until the LED flashes rapidly, then release and try adding the device again.
- Ensure the sensor's LED is steady after successful connection.
- Abnormal liquid level data:
- Check the physical installation of the sensor. Ensure it is perpendicular to the liquid surface and not too close to the water inlet or tank bulkheads.
- If the mounting surface is curved, try loosening the self-tapping screws slightly to relieve any stress on the sensor.
- Ensure there are no obstacles in the sensor's reflective area within the tank.
- Pump control not working:
- Verify the wiring of the solid-state relay and pump according to the diagrams in Section 4.2.
- Check the 'Auto Pump Control' and 'Pump Switch' settings in the app.
- Ensure the alarm thresholds (Set Max/Min) are configured correctly to trigger pump actions.
8. User Tips
- Leverage Fast Connection: Users have noted the fast connection speed and ease of use. Take advantage of this for quick setup and regular, convenient monitoring.
- Utilize Alarm Features: Set up both high and low liquid level alarms to receive timely notifications, preventing overflows or running dry.
- Review Pump Control Wiring: For models with pump control, double-check the electrical connection diagram for the smart plug and pump to ensure correct operation, especially if you intend to automate water refilling or drainage.
- Monitor Remotely: The app allows for remote monitoring, providing peace of mind and control over your liquid levels from anywhere.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact Morayelec customer service or refer to the official product page. A detailed user manual in PDF format is also available for download: User Manual (PDF).