1. Overview
The PowMr POW-RELAB series is a low-frequency hybrid solar inverter-charger designed for both residential and commercial applications. It integrates a pure sine wave inverter, a 60A MPPT solar charge controller, and an AC battery charger into a single unit. This system ensures high output stability and reliability, offering flexible energy deployment through multiple operating modes to maximize solar energy utilization and minimize self-consumption losses. It is compatible with various 24V battery types, including Lead-acid and Lithium batteries, and supports external communication via RS232 or RS482 for enhanced monitoring and management.
2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- Ensure all wiring is performed by qualified personnel.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials and ensure adequate ventilation.
- Verify battery voltage and polarity before connecting to the inverter.
- Always disconnect all power sources (solar, utility, battery) before performing any maintenance or wiring.
- The inverter is equipped with internal protection functions; however, external circuit breakers are recommended for additional safety.
3. Product Features
- High Power Output: 3000W rated power with 9000W peak power, capable of handling high surge loads like air conditioners and motors.
- Integrated Design: Combines pure sine wave inverter, 60A MPPT solar charge controller, and AC charger.
- Wide PV Input Range: Supports 30V-150V Max PV Input with a Max. PV Array Power of 1600W.
- Battery Compatibility: Designed for 24V battery systems, compatible with Lead-acid (AGM, FLD, GEL, SLD) and Lithium batteries.
- Multiple Operating Modes: Features three battery charging modes (Utility Priority, Solar Priority, Only Solar) and three output modes (Utility Priority, Solar Priority, Inverter Priority) for flexible energy management.
- Energy-Saving Mode: Minimizes equipment self-consumption.
- Robust Protection: Built-in multi-protection functions including overload, charge short, short-circuit, AC reverse, bypass overcurrent, battery overvoltage, battery low voltage, and parallel connection error protection.
- Communication Ports: Supports RS232 or RS482 for external communication and BMS communication for optimized battery operation and extended lifespan.
- High Efficiency: Over 90% conversion efficiency.
- User Interface: Equipped with an LCD HD display, LED indicators, and LCD buttons for easy monitoring and control.
- Built-in Large Transformer: Ensures enhanced load-bearing capacity and stability.
4. Setup
4.1. Physical Installation
Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for proper airflow to the cooling fans.
4.2. Component Identification

Refer to the diagram above for the location of the following components:
- LCD Screen: Displays operational status and settings.
- LED Indicators: Provide quick status updates.
- LCD Buttons: For navigation and setting adjustments.
- Toggle Switch: Main power switch.
- AC Input Terminal: Connects to utility grid or generator AC power.
- AC Output Terminal: Connects to household loads.
- Cooling Fans: For thermal management.
- PV Input Terminal: Connects to solar panels.
- Input Overcurrent Protector: Provides protection for the input circuit.
- Battery Circuit Fuse: Ensures battery circuit safety.
- Battery Negative Terminal: Connects to the negative terminal of the battery bank.
- Battery Positive Terminal: Connects to the positive terminal of the battery bank.
4.3. Wiring Connections
Follow these steps for safe and correct wiring:
- Battery Connection: Connect the 24V battery bank to the Battery Positive and Negative terminals. Ensure correct polarity. The inverter is compatible with Lead-acid (AGM, FLD, GEL, SLD) and Lithium batteries.
- PV Array Connection: Connect your solar panel array to the PV Input Terminal. Ensure the PV array voltage is within the MPPT input voltage range (30-150Vdc) and the maximum PV array power does not exceed 1600W.
- AC Input Connection: Connect the utility grid or a generator to the AC Input Terminal.
- AC Output Connection: Connect your AC loads to the AC Output Terminal.
- Communication (Optional): For external monitoring and BMS integration, connect RS232 or RS482 cables to the designated communication ports.

WARNING: Always ensure all power sources are disconnected before making or breaking any electrical connections.
5. Operating Modes
The inverter offers flexible energy management through selectable charging and output priority modes.
5.1. Battery Charging Modes

- Utility Priority: The inverter primarily uses utility power to charge the battery. Solar power will only charge the battery if utility power is unavailable.
- Solar Priority: The inverter prioritizes solar power for battery charging. Utility power will only be used if solar power is insufficient.
- Only Solar: Only solar power is used to charge the battery. Utility power is not used for charging.
5.2. Output Modes

- Utility Priority: Loads are primarily supplied by utility power. If utility power is insufficient, the inverter will switch to battery power.
- Solar Priority: Loads are primarily supplied by solar power. If solar power is insufficient, both solar and battery supply the load. If both are insufficient, the grid supplies the load.
- Inverter Priority: Loads are primarily supplied by the inverter (battery power). If battery voltage drops to a low warning point, the inverter will switch to grid power.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter.
- Cleaning: Periodically clean the exterior of the inverter, especially the cooling fans and vents, to prevent dust buildup and ensure proper heat dissipation. Use a dry, soft cloth.
- Connection Checks: Annually inspect all electrical connections (battery, PV, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
- Battery Inspection: Regularly check the battery terminals for corrosion and ensure the battery bank is in good condition, especially for lead-acid batteries.
- Environmental Check: Ensure the installation environment remains within the specified operating temperature and humidity ranges.
7. Troubleshooting
The inverter features multiple protection functions and alarm mechanisms. If an issue occurs, check the LCD display for error codes or indicators.

- Overload Protection: If the connected load exceeds the inverter's capacity, it will shut down. Reduce the load and restart the inverter.
- Charge Short Protection: Indicates a short circuit in the charging path. Check wiring for shorts.
- Short-circuit Protection: Output short circuit detected. Disconnect loads and check for faults.
- AC Reverse Protection: Incorrect AC input polarity. Verify AC input wiring.
- Bypass Over Current Protection: Excessive current drawn during bypass mode. Reduce load.
- Battery Over Voltage Protection: Battery voltage is too high. Check battery charging settings or battery health.
- Battery Low Voltage Protection: Battery voltage is too low. Recharge batteries or check battery health.
- Parallel Connection Error Protection: Issue with parallel connection setup (if applicable). Review parallel connection instructions.
For persistent issues, consult the full product manual or contact customer support.
8. Specifications
| Parameter | POW-RELAB 3KW 220V | POW-RELAB 3KW 110V |
|---|---|---|
| Input Voltage Waveform | Pure Sine Wave | |
| Nominal Input Voltage | 220Vac | 110Vac |
| AC Input Voltage Range | 154~265Vac | 77~135Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto Detection) | |
| Transfer Time | ≤10ms (UPS); ≤20ms (APL) | |
| Input /Output Protection | Circuit Breaker | |
| Rated Output Power | 3000W | |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Range | 220Vac±10% | 110Vac±10% |
| Efficiency | >98% | |
| Bypass Mode | Integrated | |
| Eco Mode | Integrated | |
| Nominal DC Input Voltage | 24Vdc | |
| Battery Type | AGM, FLD, GEL, Lithium battery | |
| Charging Current (AC) | 38A | |
| Battery Charging Voltage | 27.4VDC | |
| Battery Undervoltage Cutoff Voltage | 20V/21V | |
| Battery Undervoltage Warning Voltage | Mild discharge: 23V; Loaded discharge: 23V @ load < 20% / 22V @ load > 50% / 21V @ load > 50% | |
| Max. PV Array Power | 1600W | |
| MPPT Input Voltage Range | 30~150Vdc | |
| Max. PV Array Open Circuit Voltage | 150Vdc | |
| Max. PV Charging Current | 60A | |
| Operating Temperature | -10°C to 50°C | |
| Storage Temperature | -15°C to 50°C | |
| Humidity | Relative humidity from 5% to 95% (non-condensing) | |
| Noise | <45dB | |
| Size (L*W*H) | 620*445*130mm | |
| Weight | 21KG | |
| Is Smart Device | Yes | |
| Certification | CE | |
9. User Tips
- Battery Requirement: While the inverter can pass through solar power directly to loads under certain conditions, it is a hybrid inverter designed to work with a 24V battery bank for stable operation, energy storage, and to utilize its full range of operating modes. For optimal performance and system stability, batteries are generally required.
- Solar Input Current: The inverter's MPPT solar charger can accept a maximum PV charging current of 60A. Ensure your solar panel array's current output does not exceed this limit to prevent damage.
- Ventilation: Ensure the inverter is installed in a location with ample airflow to prevent overheating, especially during high load operation.
10. Warranty and Support
The PowMr POW-RELAB series inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact PowMr customer service through their official channels. Provide your product model and serial number for faster service.