PINTUDY J23021801 Smart Air Quality Detector User Manual

Model: J23021801 | Brand: PINTUDY

1. Product Overview

Thank you for choosing this Smart Air Quality Detector. Featuring a 32-bit ARM high-performance computing chip, this device integrates multiple high-precision sensors including an electrochemical formaldehyde sensor, infrared PM2.5 sensor, TVOC sensor, temperature sensor, and humidity sensor. It provides real-time monitoring of formaldehyde (HCHO), TVOC, PM2.5, PM1.0, PM10, as well as temperature and humidity. With the built-in fan for active air circulation and an alarm buzzer, this detector delivers accurate and reliable air quality assessment for your indoor environment.

2. Features

  • 32-bit ARM high-performance computing chip: Fast and accurate data processing.
  • Electrochemical formaldehyde sensor: High-precision HCHO detection.
  • Infrared PM2.5 sensor: Accurate particulate matter measurement (PM2.5, PM1.0, PM10).
  • TVOC sensor: Detects volatile organic compounds and benzene.
  • Temperature & humidity sensors: Comprehensive environmental monitoring.
  • Built-in fan: Active air circulation for accurate sampling.
  • Alarm buzzer: Alerts when pollutant levels exceed safe thresholds.
  • Real-time data monitoring: Continuous tracking of air quality.
  • Historical data recording: Long-term tracking of concentration trends.
  • Smart calibration: Automatic or manual calibration for accuracy.
  • Data memory: Stores historical data for trend analysis.
  • APP connectivity: View data anytime via mobile APP (for data viewing and analysis).
  • 2.8-inch LCD display: Clear display of air data, average value, real-time value, and environmental recommendations.
  • 24-hour detection: Continuous air monitoring.
  • Smart Calculator: For HCHO & PM2.5.
Diagram illustrating the features of the air quality detector, including HCHO, PM2.5, PM10, PM1, TVOC detection, air convection system, temperature, humidity, data recording, 24-hour detection, smart calculation, and memory calibration.
Figure 2.1: Key Features of the Smart Air Quality Detector

3. Product Structure and Components

Internal diagram of the air quality detector showing the location of the Electrochemical formaldehyde sensor, Infrared PM2.5 sensor, Temperature Sensor, Humidity Sensor, Fan, TVOC sensor, 32-bit ARM high-performance computing chip, and Alarm buzzer.
Figure 3.1: Internal Components Diagram
Component Function
LCD Display Shows real-time readings and system status
Electrochemical HCHO Sensor Detects formaldehyde concentration
Infrared PM2.5 Sensor Measures particulate matter (PM2.5, PM1.0, PM10)
TVOC Sensor Detects volatile organic compounds
Temperature Sensor Measures ambient temperature
Humidity Sensor Measures relative humidity
Built-in Fan Draws air across sensors for accurate sampling
32-bit ARM Chip Processes sensor data for fast, accurate results
Alarm Buzzer Sounds alerts when levels exceed thresholds
Button A Menu navigation (Up/Left)
Button B Menu navigation (Down/Right)
Button C (OK) Confirm / Enter setting
Button D (ESC) Return / Exit
USB Charging Port Charges the built-in battery

4. Display Interface

Main Screen

The main display shows the following information:

Close-up of the device display showing current time, air pollution level (e.g., 016 Fresh), HCHO (0.009 mg/m³), TVOC (0.038 mg/m³), PM2.5 (023 µg/m³), PM1.0 (015 µg/m³), PM10 (023 µg/m³), Temperature (21°C), Humidity (56%), and menu options (RT, Record, Calib, Set).
Figure 4.1: Main Display Screen
Area Display Content
Top Current time (e.g., 09:38:42)
Top Center Overall view / Air Pollution Level (e.g., 016) / Fresh (air quality status)
Middle HCHO (mg/m³), TVOC (mg/m³), PM2.5 (µg/m³), PM1.0 (µg/m³), PM10 (µg/m³), TEMP (°C), HUM (%)
Bottom Menu RT (Real-time), Record (History), Calib (Calibration), Set (Settings)

5. Setup Instructions

5.1 Power On/Off

  • Power On: Press and hold the power button (usually Button A or a dedicated power key) for 3 seconds.
  • Power Off: While powered on, press and hold the power button for 3 seconds.

Tip: Some models automatically power off after 30 minutes of inactivity.

5.2 Warm-up

After powering on, the device enters a warm-up period (typically 120-200 seconds), with a countdown displayed on the screen. During this time, sensors are stabilizing; HCHO and TVOC values will not appear until warm-up is complete. Please wait for the warm-up to finish before reading data.

5.3 Calibration (Required for First Use or After Long Periods of Inactivity)

To ensure measurement accuracy, follow these steps for first-time use or after extended storage:

  1. Power on the device and place it in a well-ventilated outdoor area (e.g., a balcony or open window).
  2. Leave it there for at least 10 minutes to allow the sensor to be exposed to clean, fresh air.
  3. Select Calib from the bottom menu, press C (OK) to confirm. The readings on the screen will reset to zero or near-zero.
  4. After calibration is complete, bring the device indoors for testing.

Caution: During calibration, ensure no one is nearby to avoid breath or movement interfering with the results. If the weather is hazy or polluted, choose a cleaner time for calibration.

6. Operating Instructions

6.1 Start Detection

  1. Place the calibrated device in the indoor environment you wish to test.
  2. The device will automatically begin detecting formaldehyde, PM2.5, TVOC, and other parameters, displaying the results in real time.

Placement Tips:

  • Keep at least 0.5m away from walls.
  • Place 0.8-1.5m above the floor.
  • Avoid air conditioner vents, windows, and humidifiers.
  • Ensure no obstructions around the device.
Diagram showing the air convection system of the detector, with arrows indicating stable and quick response airflow for accurate measurement.
Figure 6.1: Air Convection System for Accurate Sampling

6.2 Data Reading Time

  • PM2.5: Stabilizes in 1-2 minutes.
  • TVOC / HCHO: Requires 30+ minutes for accurate readings.

Continuous 24-hour monitoring is recommended to capture concentration fluctuations.

Graph showing real-time data monitoring and concentration trends over time for formaldehyde and TVOC, with indicators for increasing, stable, and decreasing values.
Figure 6.2: Real-time Data Monitoring and Trend Analysis

6.3 Menu Functions

The bottom menu offers four function options. Use Button A/B to navigate and Button C (OK) to confirm:

Function Description
RT Real-time data view (current display)
Record View historical air quality records and analysis
Calib Enter calibration mode
Set System settings (time, units, etc.)

Press D (ESC) to return to the previous menu.

6.4 Historical Data Viewing

To view historical data:

  1. Select Record from the bottom menu.
  2. The device displays historical data including:
    • HCHO, TVOC, PM2.5 readings with timestamps
    • Temperature and humidity records
    • Concentration trends over time
  3. Use Button A/B to scroll through historical records.
  4. Press D (ESC) to return to the main screen.
Device display showing historical data with a graph of HCHO concentration over time, from 0:00 to 15:00.
Figure 6.3: Historical Data Display

6.5 Trend Analysis

The device provides visual trend analysis:

Trend Indicator Meaning
Value increasing Pollutant concentration rising - ventilation needed
Value stable Indoor environment healthy and livable
Value decreasing Pollutant levels dropping - improvement in progress

6.6 System Settings

To access system settings:

  1. Select Set from the bottom menu.
  2. Use Button A/B to navigate through setting options:
    • Current Time - Set date and time
    • Record Time - Set data recording interval
    • Measuring Speed - Adjust sampling frequency
    • Data Collection - Manage stored data
    • Factory Settings - Reset to default settings
  3. Press C (OK) to enter a setting, use Button A/B to adjust values, and press C (OK) to save.
  4. Press D (ESC) to exit settings.

7. Maintenance

7.1 Precautions

  • Do not block the air inlet during use, as this may affect accuracy.
  • Keep away from high temperature, high humidity, and strong electromagnetic interference.
  • Avoid chemical contamination - keep alcohol, perfumes, and air fresheners away from the device.
  • Keep dry - do not expose to water or other liquids.
  • Do not disassemble - do not modify or repair the device yourself.
  • Environmental limits: Do not use at temperatures below 0°C or above 40°C, or humidity above 90% RH.
  • Avoid direct airflow - fans and air conditioners can interfere with readings.
  • Avoid activity near the device during measurement - no smoking, perfumes, or cleaning agents nearby.
  • Allow stabilization time - HCHO and TVOC readings require 30+ minutes to stabilize.

7.2 Regular Calibration

Calibrate quarterly or when data appears abnormal. Refer to section 5.3 for calibration instructions.

8. Troubleshooting

  • Device does not turn on: Check the battery level and charge it using the provided USB cable.
  • Inaccurate readings: Ensure the device has completed its warm-up period. Perform a calibration in a well-ventilated outdoor area. Avoid using the device in extreme temperatures or humidity, or near sources of interference.
  • No HCHO/TVOC readings: These values will not appear until the warm-up period is complete (typically 120-200 seconds).
  • Unstable readings: Allow the device to stabilize for at least 30 minutes, especially for HCHO and TVOC. Ensure proper placement away from airflow and obstructions.

9. Specifications

Parameter Specification
Product Name Smart Air Quality Detector
Model Number J23021801
Display 2.8-inch LCD with backlight
Detection Parameters HCHO, TVOC, PM2.5, PM1.0, PM10, Temperature, Humidity, CO2 (implied by 'co2 meter analyzer' in title, though not explicitly listed in PDF specs)
HCHO Sensor Electrochemical sensor
PM2.5 Sensor Infrared sensor
TVOC Sensor Semiconductor sensor
Computing Chip 32-bit ARM high-performance chip
Air Circulation Built-in fan
Alarm Buzzer
Data Storage Historical data recording
Connectivity APP support (data viewing and analysis)
Calibration Smart calibration / Memory calibration
Dimensions Approx. 151 x 69 x 45 mm (5.9 x 2.7 x 1.7 in)
Power Supply Built-in 1200mAh lithium battery / USB charging
Detection error Less than 15%
Formaldehyde detection range 0.000-1.999 mg/m³
TVOC detection range 0.000-1.999 mg/m³
PM1.0/PM2.5/PM10 detection range 0-999 µg/m³
Temperature measurement range 0-50 Celsius
Humidity measurement range 20~90%RH
Standby time About 240-360 minutes (4-6 hours)
Charging time About 4 hours
Life time (operating) About 2 hours
USB interface Type-C interface
Input voltage 5V/1A
Working environment 5-40 Celsius, Less than 90%RH
Color Black orange
Material Plastic
Image of the air quality detector held in a hand, showing its dimensions: 151mm (5.9in) height, 69mm (2.7in) width, and 45mm (1.7in) depth.
Figure 9.1: Device Dimensions

10. Sensor Technology

Sensor Type Function
Electrochemical HCHO Sensor Detects formaldehyde with high precision and selectivity
Infrared PM2.5 Sensor Measures particulate matter using light scattering technology
TVOC Sensor Detects a wide range of volatile organic compounds
Temperature Sensor Monitors ambient temperature
Humidity Sensor Monitors relative humidity
Built-in Fan Ensures continuous airflow across sensors for accurate readings
Diagram showing the advanced sensor technology, including laser scattering particle acceleration measurement, 32-point combined calibration, and a new core algorithm for enhanced accuracy.
Figure 10.1: Advanced Sensor Technology

11. Reference Standards

Parameter Normal Range Reference
HCHO (Formaldehyde) 0.000 - 0.080 mg/m³
TVOC 0.000 - 0.600 mg/m³
PM2.5 0 - 35 µg/m³ (Good)

The above values are for reference only. Please refer to national air quality standards (e.g., GB/T 18883-2022) for official guidelines.

12. User Tips

  • This detector is generally considered more accurate than many cheaper alternatives.
  • The screen is easy to read, and the buttons are convenient for navigation.
  • It is normal to hear the internal fan operating when the device is turned on; this ensures proper air circulation for sampling.
  • Always perform initial calibration and allow sufficient warm-up time (120-200 seconds) for the device to stabilize, especially for HCHO and TVOC readings (30+ minutes).
  • If you notice discrepancies in temperature readings, ensure the device is placed in an area with stable ambient temperature and away from direct heat sources or drafts.

13. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's specific terms and conditions or contact their customer service directly. Please note that this manual provides operational instructions and does not constitute a warranty statement.

A PDF version of this user manual is available for download: User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.