1. Product Overview
The SUSWE 12V6A built-in switch power module is a high-power, small-sized Gallium Nitride (GaN) AC to DC bare board, offering 72W output. This power module is designed with high reliability, low power consumption, and safe isolation. Its compact size and robust features make it ideal for a wide range of applications including industrial control, power instrumentation, smart home devices, and new energy systems where space is a critical factor. It is compatible with appropriate EMC peripheral circuits to meet various industry requirements.
2. Specifications
| Feature | Specification |
|---|---|
| Type | Power Supply |
| Brand Name | SUSWE |
| Model Number | 12V6A (SUS-60-MIN-12V) |
| Product Series | Gallium Nitride Series |
| Input Voltage Range | 90Vac~264Vac or 120Vdc~375Vdc |
| Normal Input Voltage | 110Vac~240Vac |
| Input Frequency Range | 47Hz~63Hz |
| Max. Input Current | 2.0A Max. at full load condition 220Vac |
| Inrush Current (cold start) | 70A Max. at 264Vac |
| Efficiency (full load) | 90% MIN@full Load 230Vac |
| Standby Power Loss | 3.5W |
| Output Type | SINGLE |
| Output Voltage | 12V (±5% accuracy) |
| Output Current | 6A (6000mA rated) |
| Output Power | 72W (101 - 200W range) |
| Output Frequency | 50-60HZ |
| Load Adjustment Rate | ±3% |
| Ripple & Noise | 240mVp-p Max. |
| Hold-Up Time | ≥10mS (at 110Vac/220Vac input) |
| Product Size | 69.6mm × 36.55mm × 21.5mm |
| Installation Size | 63mm × 30mm |
| Weight | 70.34g |
| Installation Method | Screw fixation |
| Certification | CE |
| EU LVD Voltage | Below 50Vac or 75Vdc |
Note on Ripple & Noise: Tested by loading side parallel with a 10uF/EC and 0.1uF/Ceramic capacitors and Measured Band-Width with DC-20MHz.
3. Safety Information
- Always ensure proper usage. Incorrect methods may lead to electric shock, product breakage, smoke, or light emission.
- Do not place any objects on the product before powering it on. This can cause damage, deformation, or overheating.
- Avoid placing the product in environments with high temperature, high humidity, dust, or corrosive substances, as this may lead to damage or electric shock.
4. Installation and Wiring
The power module is designed for screw fixation. Ensure the installation area provides adequate ventilation for natural air cooling.



Wiring Instructions
Refer to the video demonstration for visual guidance on wiring. Ensure all connections are secure and correctly polarized.
- AC Input (110~240V): Connect the AC input wires to the designated "+" and "-" terminals.
- DC Output (12V): Connect the DC output wires to the designated "+" and "-" terminals.
Demonstration of the power module's wiring for AC input and DC output, followed by a test showing a ribbon light strip powered on successfully. Also shows a water immersion test for durability.
Dimensional Diagrams
For precise physical dimensions and PCB layouts, refer to the following diagrams:



5. Operation
Once properly installed and wired, apply the specified AC input voltage (90-264V). The module will convert this to a stable 12V DC output. Verify the output voltage and current with appropriate measuring devices before connecting your load. The module is designed for continuous operation within its specified environmental conditions.
Applications
This power module is suitable for a variety of uses, including:
- Electronic Equipment
- Car Notebooks
- Solar Photovoltaic Power Generation systems
- DIY Adjustable Regulated Power Supplies
6. Protection Features
The SUSWE 12V6A power module incorporates several protection mechanisms to ensure safe and reliable operation:
- Short Circuit Protection: Features hiccup mode and auto-recovery. In case of a short circuit, the output will temporarily shut down and attempt to recover automatically once the fault is removed.
- Over Current Protection: Activates when the output current exceeds 6.5A. It operates in hiccup mode with auto-recovery.
- Over Voltage Protection: Provides hiccup mode and auto-recovery in the event of an overvoltage condition. This protection should be tested at all input voltages and with minimum or no load.
7. Environmental Requirements
To ensure optimal performance and longevity, operate the power module within the following environmental conditions:
- Operating Temperature: 0°C to 50°C
- Storage Temperature: -10°C to 70°C
- Operating Humidity: 10% to 85% (non-condensing)
- Storage Humidity: 5% to 95% (non-condensing)
- Altitude: Up to 5000m
- Vibration (Operating): 5-17Hz (0.048 inch double amplitude displacement), 17-199Hz (0.73Gs acceleration), 200-500Hz (0.33Gs acceleration, 30min sweep).
- Vibration (Storage): 2-200Hz (2.0G peak to peak, 3 axes, 30min sweep).
- Cooling Method: Natural air cooling (Ventilation Cooling).
8. Maintenance and Storage
The power module is designed for minimal maintenance. However, proper storage and occasional checks can extend its lifespan:
- If the product is stored for longer than 6 months under specified storage conditions, it is recommended to power it on and let it operate for at least 2 hours. Failure to do so may shorten its product life.
- Keep the module clean and free from dust accumulation to ensure efficient heat dissipation.
- Regularly inspect for any signs of physical damage or loose connections.
9. User Tips
- Always double-check your input and output voltage/current requirements against the module's specifications before connecting.
- Ensure adequate ventilation around the module to facilitate natural air cooling and prevent overheating.
- When integrating into a custom project, consider the installation size (63mm x 30mm) and ensure secure screw fixation.
10. Further Documentation
For detailed technical specifications, PCB layouts, and additional information, please refer to the official User Manual (PDF) available at: User Manual (PDF).