1. Introduction
The JIKONG JK-B2A8S20P is an intelligent Battery Management System (BMS) designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge protection, overcurrent protection, over-temperature protection, coulomb meter, Bluetooth communication, and optional GPS remote functionality. This BMS is compatible with various battery types, including Li-ion, LiFePO4, and LTO batteries, supporting 4S to 8S configurations.
The protection board utilizes energy transfer active balancing technology, capable of achieving a continuous 1A/2A balance current. This high-current active equalization technology ensures battery consistency, extends battery life, and delays aging. The system is managed via a mobile APP (Android and iOS) connected via Bluetooth, allowing users to monitor battery status, modify parameters, and control charge/discharge switches. Its compact size and comprehensive functions make it suitable for a wide range of applications, including small electric vehicles, energy storage systems, and solar power stations.
2. Safety Information
Always handle battery packs and BMS components with care. Ensure all connections are correct before powering on the system to prevent damage or injury. Do not expose the BMS to extreme temperatures or moisture. If you are unsure about any installation or operation steps, consult a qualified professional.
3. Product Features
- Active Balancing: 1A/2A continuous active balancing current for optimal cell consistency.
- Wide Compatibility: Supports 4S-8S Li-ion, LiFePO4, and LTO battery packs.
- High Current Capacity: Maximum charging/discharging current of 200A.
- Comprehensive Protection: Overcharge, over-discharge, overcurrent, over-temperature, low-temperature, and short-circuit protection.
- Smart Monitoring: Bluetooth connectivity for mobile APP (Android/iOS) monitoring and parameter adjustment.
- Data Acquisition: High-precision voltage (±3mV) and current acquisition.
- Display Support: Supports external display screens for real-time information.
- Optional Functions: Heating function for low-temperature environments, GPS communication, RS485/CAN communication.
- Intelligent Sleep Mode: Reduces self-consumption when idle.
- Emergency Switch: Provides 30 minutes of operation in critical situations.



4. Package Contents
The standard package for the JIKONG JK-B2A8S20P BMS includes the following items:
- BMS Unit x 1
- Sampling Line x 1 (70cm long)
- NTC Temperature Sensor x 1 (40cm long)
- Switch Key x 1 (50cm long)

5. Specifications
5.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 10-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max. Number of Collection Strings | 8 | String |
| Max. Balancing Current | 2 | A |
| Max. Charging Current | 200 | A |
| Max. Discharge Current | 200 | A |
| Max. Instantaneous Current | 400 | A |
| Max. Internal Loop Resistance | 0.4 | mΩ |
| Protective Plate Size (L*W*H) | 153*126*17.6 | mm |
| Finished Weight | 349 | g |
5.2. Default Parameters
| Parameter | Li-ion (V) | LiFePO4 (V) | LTO (V) |
|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 |
| Max. Balancing Current (A) | 2 | 2 | 2 |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 |
| Charging Overcurrent Protection Delay (S) | 30 | 30 | 30 |
| Charging Overcurrent Protection Release Time (S) | 60 | 60 | 60 |
| Discharge Overcurrent Protection Delay (S) | 300 | 300 | 300 |
| Discharge Overcurrent Protection Release Time (S) | 60 | 60 | 60 |
| Short-circuit Protection Delay (µS) | 1500 | 1500 | 1500 |
| Short-circuit Protection Release Time (S) | 60 | 60 | 60 |
| Charging Overtemperature Protection (°C) | 70 | 70 | 70 |
| Charging Overtemperature Recovery (°C) | 60 | 60 | 60 |
| Discharge Overtemperature Protection (°C) | 70 | 70 | 70 |
| Discharge Overtemperature Recovery (°C) | 60 | 60 | 60 |
| Charging Low Temperature Protection (°C) | -20 | -20 | -20 |
| Charging Low Temperature Recovery (°C) | -10 | -10 | -10 |
| MOS Overtemperature Protection (°C) | 100 | 100 | 100 |
| MOS Overtemperature Recovery (°C) | 80 | 80 | 80 |
| Device Address | 0 | 0 | 0 |
| Discharge Precharge Time (S) | 0 | 0 | 0 |
5.3. Product Dimensions

Note: The data tolerance range is ±2mm.
6. Installation and Wiring
Before installation, carefully inspect the package and the BMS unit for any signs of impact or damage. Handle the unit gently and avoid inverting it. The JK-B2A8S20P series protection board is suitable for 3-8 series lithium battery packs. The wiring method varies depending on the number of cells in your battery pack.
6.1. Wiring Method for 8-String Cells
Follow the diagram below for connecting an 8-string battery pack. Ensure all cables are connected correctly, insert the cable into the BMS, and connect the B-line and P-line to the battery.

6.2. Wiring Method for 4-String Cells
For a 4-string battery pack, refer to the following diagram. The principles of connecting cables, inserting into the BMS, and connecting B-line and P-line remain the same.

6.3. Interface Definitions
The BMS features various interfaces for communication, display, and sensors. Below is a detailed breakdown of the connectors and their pin definitions.

Important: Before powering on the protection board, double-check that the balance cable is properly connected and that the P- and B- lines are correctly wired. Ensure the protection board is securely fixed to the battery cells. Incorrect connections can lead to abnormal operation or even damage.
7. Operating Instructions
7.1. Device Activation
The BMS does not have a physical power-on switch. It is designed to activate in charging mode. After the battery assembly is complete, connect a charger (with voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if you have an optional display screen and button, you can activate the BMS by inserting the cable into the display interface and pressing the button.7.2. Active Equalization
The active balancing function transfers energy from higher voltage cells to lower voltage cells. To use this feature, set the basic battery parameters (battery type, number of cells, capacity) in the JIKONG BMS APP. You can also adjust the balance trigger voltage difference (mV) and the balance current (recommended not to exceed 0.2C of battery capacity). Balancing automatically starts when the voltage difference between any two strings exceeds the set value and stops when it falls below the set value. If balancing is not required, it can be turned off in the APP's BMS control page.
7.3. GPS and Display Interface
The BMS includes a reserved GPS port for optional GPS modules, allowing for battery location tracking. It also has a display interface to connect JIKONG display screens for convenient real-time battery information viewing. Users can choose these options based on their needs.
7.4. Heating Function (Optional)
For low-temperature environments, the optional heating function uses a resistance heater or heating film to warm the battery, preventing performance degradation due to cold. The designed heating current is 4A. This function can be controlled via the APP's BMS control page. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary safety measure.
7.5. Communication Function (Optional)
The BMS supports optional CAN/RS485 communication. Users can select the desired communication protocol and set the BMS address via the APP's BMS control page. Refer to the JIKONG Protection Board Communication Protocol document for specific details.
7.6. Intelligent Sleep Mode
The intelligent sleep function is standard. When the BMS is in standby (charging/discharging current less than 1A for 26 consecutive hours), it can enter sleep mode to reduce self-consumption. To reactivate, press a button (if available) or connect a charger.
7.7. Discharge Precharge Function (Optional)
The optional discharge precharge function has a default precharge time of 5 seconds. Users can enable or disable this function via the APP. Setting the precharge time to 0 disables the function.
7.8. Emergency Switch
The standard emergency switch function allows the BMS to continue charging and discharging for 30 minutes in case of over-temperature, over-discharge, over-charge, or cell string issues. This provides a temporary operational window to prevent immediate shutdown, which can be critical in certain situations.
8. APP Operation Instructions
8.1. APP Installation
Download the JIKONG BMS mobile APP by scanning the QR code below. An Android device requires Android Version 7 or higher.

8.2. Parameter Setting
Once the APP is installed and the device is activated, you can access the parameter settings. Here you can customize various protection values such as overcharge, over-discharge, overcurrent, temperature, and balance settings. Always refer to the detailed parameter setting guide within the APP or the full PDF manual for specific instructions before making changes.





9. Protection Functions and Troubleshooting
The JIKONG JK-B2A8S20P BMS is equipped with multiple protection mechanisms to ensure the safety and longevity of your battery pack. When a protection is triggered, the BMS will take action (e.g., stop charging/discharging) and will recover once the condition is resolved.
9.1. Charge Overvoltage Protection and Recovery
If any cell voltage exceeds the set overcharge protection voltage during charging, the BMS will stop charging. Charging will resume once all cell voltages drop below the overcharge recovery voltage. This prevents cell damage from overcharging.
9.2. Discharge Undervoltage Protection and Recovery
If any cell voltage drops below the set undervoltage protection voltage during discharge, the BMS will stop discharging. Discharge will resume once all cell voltages rise above the undervoltage recovery voltage (e.g., after charging). If any cell voltage falls below the automatic shutdown voltage, the BMS will shut down to protect the cells from deep discharge.
9.3. Charge Overcurrent Protection and Recovery
If the charging current exceeds the set continuous charging current for a specified delay time, the BMS will stop charging. Charging will resume after the overcurrent release time has passed. This protects against excessive charging currents.
9.4. Discharge Overcurrent Protection and Recovery
If the discharge current exceeds the set continuous discharge current for a specified delay time, the BMS will stop discharging. Discharge will resume after the overcurrent release time has passed. This protects against excessive discharge currents. Note: The maximum continuous discharge current should not exceed 200A.
9.5. Overtemperature Protection and Recovery
If the BMS detects that the temperature (charging or discharging) exceeds the set overtemperature protection value, the corresponding operation (charging or discharging) will stop. The operation will resume once the temperature drops below the recovery temperature. This protects the battery and BMS from heat damage.
9.6. Low Temperature Protection and Recovery
If the BMS detects that the charging temperature falls below the set low-temperature protection value, charging will stop. Charging will resume once the temperature rises above the recovery temperature. This prevents damage to cells from charging in cold conditions. For extremely cold regions, consider using the optional heating function.
9.7. Short Circuit Protection and Recovery
The BMS includes standard short-circuit protection. If a short circuit is detected, the BMS will immediately stop the operation. After a specified recovery time, the BMS will attempt to resume operation. If the short circuit persists, it will trigger again. Users can adjust the short-circuit protection delay and recovery time via the APP if needed, especially when connecting loads with high inrush current or chargers with high peak output.
10. Maintenance
The JIKONG BMS is designed for durability and minimal maintenance. However, regular checks can help ensure optimal performance and longevity:
- Visual Inspection: Periodically inspect the BMS and wiring for any signs of damage, corrosion, or loose connections.
- Software Updates: Check the JIKONG official website or APP for any firmware updates to ensure you have the latest features and bug fixes.
- Cleanliness: Keep the BMS free from dust and debris. Use a soft, dry cloth for cleaning.
- Temperature Monitoring: Ensure the BMS operates within its specified temperature range. If using the heating function, verify its proper operation in cold conditions.
11. User Tips
- Initial Setup: Always connect the balance wires first, then the B- and P- lines. Double-check all connections before applying power.
- APP Customization: Take advantage of the mobile APP to fine-tune protection parameters to match your specific battery chemistry and application needs.
- Active Balancing: For new battery packs or after significant use, monitor the active balancing function to ensure cell voltages remain consistent. Adjust the balancing current if necessary.
- Temperature Management: If operating in cold climates, consider enabling the heating function and ensure proper insulation for your battery pack.
- Firmware Updates: Regularly check for and install any available firmware updates for your BMS to benefit from performance improvements and new features.
- Documentation: Keep this manual and the full PDF user manual accessible for reference, especially for detailed parameter settings and wiring diagrams.
12. Support and Further Documentation
For detailed technical specifications, advanced parameter settings, and comprehensive wiring diagrams, please refer to the official user manual PDF:
For further assistance or inquiries, please visit the JIKONG official website or contact their customer support.