1. Introduction and Overview
The JIKONG JK-B2A8S20P is an intelligent Battery Management System (BMS) designed for large-capacity series lithium battery packs. It supports 4 to 8 series battery configurations for Li-ion, LiFePO4, and LTO battery types.
This BMS offers comprehensive battery management, including voltage acquisition, high current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote functionality.
The active balancing technology ensures energy transfer from higher-voltage cells to lower-voltage cells, achieving voltage balance with minimal energy loss. This process operates continuously during charging, discharging, or idle states until the voltage difference is within a set range. This non-lossy balancing method is highly efficient and suitable for larger battery capacities.


2. Setup and Installation
2.1. Unpacking and Inspection
Upon receiving your JIKONG BMS, handle the packaging and the protection board gently. Before opening, inspect the package for any signs of impact or damage. Ensure all components listed in the packing list are present and in good condition.
2.2. Packing List
- BMS x 1
- Sampling Cable x 1 (70cm long)
- NTC (Temperature Sensor) x 1 (40cm long)
- Switch Key x 1 (50cm long)

2.3. Wiring Diagrams
The JK-B2A8S20P BMS is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure correct connections to avoid damage.
Wiring for 8-String Cells

Wiring for 4-String Cells

2.4. Interface Definition
The BMS features various interfaces for connectivity and functionality:
| Connector | Pin Number | Name | Definition |
|---|---|---|---|
| Balance & Acquisition (XH-10AW) | 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive | |
| 3 | B2 | The second battery positive | |
| 4 | B3 | The third battery positive | |
| 5 | B4 | The fourth battery positive | |
| 6 | B5 | The fifth battery positive | |
| 7 | B6 | The sixth battery positive | |
| 8 | B7 | The seventh battery positive | |
| 9 | B8 | The eighth battery positive | |
| 10 | B+ | Protection board power supply, connected to the battery | |
| Heating Interface (A1254WF-7A) | 1-5 | HT- | Heater element negative electrode |
| 6 | CD+ | Charge indication input positive terminal | |
| 7 | CD- | Charge indication input negative terminal | |
| P- | P- | Connect to external load or negative terminal of charger | |
| B- | B- | Connect to the negative battery terminal | |
| Display Interface (A1254WF-6A) | 1 | VCC | Display power output |
| GPS Interface (1.25T-4PWT) | 1 | VGPS | Power output, voltage close to B+ |
| 2 | TX | UART TX, 3.3V | |
| 3 | RX | UART RX, 3.3V | |
| 4 | GND | Power/signal ground | |
| Communication Interface (A1254WF-3A) | 1 | DN | CAN L/RS485-B signal negative |
| 2 | DP | CAN H/RS485-A signal positive | |
| 3 | GND | Signal ground | |
| Temperature Interface (HY2.0-4P) | 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B | |
| 3 | T2A | Second temperature sensor pin A | |
| 4 | T2B | Second temperature sensor pin B |
3. Operating Instructions
3.1. APP Installation
The JIKONG BMS features a mobile application for Android and iOS operating systems. Scan the QR code below to download the official APP. Android devices require a minimum of Android 7.

3.2. Device Activation
Before powering on the protection board, double-check that the balance cables are correctly connected and that the P- and B- terminals are properly wired. Ensure the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.
The BMS does not have a physical power-on switch. It is designed for charging activation: after battery assembly, connect a charger (with voltage 2V higher than battery voltage) to activate the board. Alternatively, if you have an optional display screen and button, you can activate the BMS by inserting the cable into the display interface and pressing the button.
3.3. Active Equalization
The active equalization function transfers energy from high-voltage cells to low-voltage cells. Before using, set basic battery parameters in the APP, including battery type, number of cells, battery capacity, and trigger voltage difference. The default balance current is 1A/2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. The balancing switch can be turned off in the APP's BMS control page if not needed.

3.4. GPS and Display Interface
The BMS includes a reserved GPS port for optional GPS modules, allowing for battery location tracking. It also has a display interface for connecting JIKONG display screens to view battery information conveniently.


3.5. Heating Function (Optional)
The optional heating function uses a resistance heater or heating film to warm the battery in low-temperature conditions, preventing reduced battery activity. The designed heating current is 4A. Users can enable/disable this function via the APP. For secondary protection, it's recommended to install a normally closed temperature switch (45°C to 65°C) in series with the heating circuit.
4. Protection Functions and Troubleshooting
The JIKONG BMS includes various protection mechanisms to ensure battery safety and longevity. When a protection is triggered, the BMS will take action to prevent damage and will recover once conditions return to normal. Troubleshooting often involves checking APP parameters and external connections.
4.1. Charge Overvoltage Protection and Recovery
The BMS protects against overvoltage during charging. Users can set the single overcharge protection voltage and recovery voltage in the APP. If any cell exceeds the set voltage, charging will stop. Charging resumes when all cell voltages drop below the recovery voltage.
4.2. Discharge Undervoltage Protection and Recovery
This function prevents over-discharge. Users can set the undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell drops below the protection voltage during discharge, discharge will stop. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will automatically shut down.
4.3. Charge Overcurrent Protection and Recovery
Protects against excessive charging current. Users can set continuous charging current, overcurrent delay, and recovery time in the APP. If the charging current exceeds the set value for the specified delay, charging will stop. Charging resumes after the set recovery time.
4.4. Discharge Overcurrent Protection and Recovery
Protects against excessive discharging current. Users can set continuous discharge current, overcurrent delay, and recovery time in the APP. If the discharge current exceeds the set value for the specified delay, discharge will stop. Discharge resumes after the set recovery time. Note: Maximum continuous discharge current should not exceed 200A.
4.5. Overtemperature Protection and Recovery
The BMS monitors battery temperature during charge and discharge. Users can set overtemperature protection and recovery values in the APP. If the temperature exceeds the set limit, charging or discharging will stop. Operation resumes when the temperature drops below the recovery value.
4.6. Low Temperature Protection and Recovery
Protects against charging at dangerously low temperatures. Users can set low temperature protection and recovery values in the APP. If the temperature drops below the set limit during charging, charging will stop. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, consider using the optional heating function.
4.7. Short Circuit Protection and Recovery
This function is standard and does not require manual current settings. Users can adjust the short circuit protection delay and recovery time in the APP. If a short circuit occurs, the BMS will trigger protection. Increasing the delay can help prevent false triggers from high instantaneous currents during charger startup or load connection.
4.8. Discharge Precharge Function (Optional)
This optional function allows for precharging before discharge. The default precharge time is 5 seconds. Users can enable/disable this function and adjust the time via the APP. Setting the time to 0 disables precharge.
4.9. Emergency Switch
The emergency switch function, accessible via the APP, allows the BMS to maintain charge and discharge for 30 minutes even if over-temperature, over-discharge, over-charge, or cell drop issues occur. This provides a temporary operational window in critical situations.
4.10. Intelligent Sleep
The intelligent sleep function, configurable in the APP, puts the BMS into a low-power standby mode (if charge/discharge current is less than 1A for 26 consecutive hours) to reduce self-consumption. The BMS can be reactivated by pressing a button or connecting a charger.
4.11. Communication Function
The BMS supports optional CAN/RS485 communication. Users can select the desired protocol and configure the address and communication protocol via the APP based on their specific requirements. Refer to the JIKONG Protection Board communication protocol document for details.
5. Specifications
5.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 10-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 8 | String |
| Maximum Balancing Current | 2 | A |
| Maximum Charging Current | 200 | A |
| Maximum Discharge Current | 200 | A |
| Maximum Instantaneous Current | 400 | A |
| Maximum Internal Loop Resistance | 0.4 | mΩ |
| Finished Weight | 349 | g |

5.2. Default Parameters (JK-B2A8S20P)
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 2 | 2 | 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charging Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 1500 | 1500 | 1500 | µS |
| Short Circuit Protection Release Time | 60 | 60 | 60 | S |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charging Overtemperature Recovery | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charging Low Temperature Recovery | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
| Discharge Precharge Time | 0 | 0 | 0 | S |
5.3. Product Dimensions
The dimensions of the JK-B2A8S20P series protection board are 153mm x 126mm x 17.6mm.

6. Maintenance
To ensure optimal performance and longevity of your JIKONG BMS, follow these general maintenance guidelines:
- Keep Clean: Regularly clean the BMS and its connections to prevent dust and debris buildup, which can affect performance and heat dissipation.
- Avoid Physical Damage: Protect the BMS from impacts, vibrations, and moisture. Ensure it is securely mounted in its intended location.
- Ensure Proper Ventilation: If the BMS is enclosed, ensure adequate airflow to prevent overheating, especially during high current operation or when the heating function is active.
- Regularly Check Connections: Periodically inspect all wiring connections (balance cables, power cables, sensor cables) to ensure they are secure and free from corrosion. Loose connections can lead to unstable operation or damage.
- Monitor via APP: Use the mobile APP or PC software to regularly monitor battery parameters and BMS status. This helps in early detection of potential issues.
7. User Tips
While no specific user reviews or Q&A data were provided, here are some general tips for maximizing your JIKONG BMS experience:
- Customize Parameters: Take advantage of the APP's parameter settings to fine-tune protection thresholds and balancing currents according to your specific battery chemistry and usage patterns.
- Monitor Actively: Regularly check the battery status via the mobile APP. This allows you to observe cell voltages, temperatures, and overall battery health, helping you understand your battery's behavior and identify any anomalies early.
- Consider Optional Accessories: If your application requires precise location tracking or a dedicated visual interface, consider integrating the optional GPS module or a JIKONG display screen.
- Proper Cable Management: Ensure all cables are neatly routed and secured to prevent accidental disconnections or damage from vibration.
8. Warranty and Support
For detailed warranty information and technical support, please refer to the official JIKONG documentation or contact your seller. The comprehensive user manual (PDF) provides in-depth information on product usage and troubleshooting.
You can access the full user manual PDF here: JIKONG JK-BxA8S-20P User Manual (PDF)