EXFO Max-710b-M1

Contents

EXFO MaxTester 710B-M1 OTDR User Manual

Your guide to operating and maintaining your fiber optic test equipment.

1. Introduction

The EXFO MaxTester 710B-M1 is a robust and intuitive Optical Time Domain Reflectometer (OTDR) designed for efficient and accurate fiber optic network testing. This compact, handheld device is ideal for field technicians, offering a user-friendly interface and comprehensive testing capabilities for single-mode fibers. It supports dual wavelengths (1310/1550nm) and provides a dynamic range of 30/28dB, making it suitable for various fiber installation and maintenance tasks.

EXFO MaxTester 710B-M1 OTDR front view with active fiber trace display
Front view of the EXFO MaxTester 710B-M1, highlighting its large touchscreen display with a typical OTDR fiber trace and event table. The interface includes 'Source', 'OTDR', 'iOLM', 'Events', 'Summary' tabs, and 'Pass' indicator.

2. Package Contents

Before using your EXFO MaxTester 710B-M1, please verify that all items are present in the package:

  • EXFO MaxTester 710B-M1 OTDR Unit
  • AC/DC Power Adapter
  • Power Cord
  • USB Cable
  • Quick Reference Guide
  • Summary View Documentation
  • Event Table Icons Documentation
  • Carrying Case
  • Fiber Optic Patch Cable (may vary by configuration)
  • Visual Fault Locator (VFL) (may vary by configuration)
EXFO MaxTester 710B-M1 OTDR package contents
This image illustrates the complete package contents: the EXFO MaxTester 710B-M1 unit, AC/DC power adapter, power cord, USB cable, and user documentation.
EXFO MaxTester 710B-M1 OTDR and accessories in carrying case
The MaxTester 710B-M1 and its essential accessories, including a fiber optic patch cable and a visual fault locator (VFL), neatly stored within the protective carrying case.

3. Device Overview

Familiarize yourself with the physical features and connection points of your MaxTester 710B-M1.

Top view of EXFO MaxTester 710B-M1 OTDR showing connectivity ports
The top panel of the MaxTester 710B-M1 features the OTDR port, iOLM port, USB ports, and an RJ-45 LAN port for connectivity.

Key Components:

  • OTDR Port: For connecting to the fiber under test.
  • iOLM Port: For Intelligent Optical Link Mapper functionality.
  • USB 2.0 Ports: For connecting to external devices like USB drives or a PC.
  • RJ-45 LAN Port: For network connectivity (10/100 Mbit/s).
  • Power Input: For connecting the AC/DC power adapter.
Back view of EXFO MaxTester 710B-M1 OTDR with product labels
The rear of the device displays important product information, including model number (MAX-710B-M1), serial number, manufacturing date, and safety warnings regarding laser radiation.

4. Setup

4.1 Charging the Battery

  1. Connect the AC/DC power adapter to the power input port on the MaxTester 710B-M1.
  2. Plug the power cord into a suitable electrical outlet (100-240 VAC, 50-60 Hz).
  3. The device will begin charging. A full charge provides approximately 12 hours of operation.

4.2 Powering On/Off

  • To Power On: Press and hold the power button until the EXFO logo appears on the screen.
  • To Power Off: Press and hold the power button until a shutdown prompt appears, then confirm.

4.3 Initial Configuration

Upon first power-on or after a factory reset, you may need to configure basic settings such as language, date, and time. Follow the on-screen prompts to complete this setup.

4.4 Connecting to a PC or Network

  • USB Connection: Use the provided USB cable to connect the MaxTester to a computer for data transfer or software updates.
  • LAN Connection: Connect an Ethernet cable to the RJ-45 port to integrate the device into a local area network for remote management or data sharing.

5. Operating Instructions

5.1 Basic OTDR Testing

  1. Clean Connectors: Always ensure fiber optic connectors are clean before connecting them to the OTDR. Use appropriate fiber cleaning tools.
  2. Connect Fiber: Connect the fiber under test to the OTDR port using a suitable launch cable if necessary.
  3. Select Mode: On the touchscreen, navigate to the 'OTDR' tab.
  4. Configure Test Parameters: Set parameters such as wavelength (1310nm or 1550nm), pulse width, and distance range according to the fiber type and length being tested.
  5. Start Test: Press the 'Start' button to initiate the OTDR trace.
  6. Analyze Results: The device will display the fiber trace, event table, and summary results. Analyze the trace for events like splices, connectors, and breaks.

The iOLM feature simplifies OTDR testing by providing a single-button operation that automatically sets parameters, performs multiple acquisitions, and presents results in an icon-based link view. This eliminates the need for complex trace analysis.

  1. Connect Fiber: Ensure the fiber is properly connected to the iOLM port.
  2. Select iOLM Tab: Tap the 'iOLM' tab on the display.
  3. Start Test: Press the 'Start' button. The iOLM will automatically perform the necessary tests.
  4. Review Link Map: The results will be displayed as a clear, intuitive link map with icons representing different events and their characteristics.

5.3 Saving and Managing Data

Test results can be saved to the device's internal memory (2 GB, typical 20,000 OTDR traces) or transferred to external storage via USB.

  • Saving: After a test, use the 'Save' option on the screen to store the results.
  • Transferring: Connect the device to a PC via USB and access the internal storage to copy files.

6. Maintenance

6.1 Cleaning the Device

  • Exterior: Use a soft, damp cloth to clean the exterior of the device. Avoid abrasive cleaners or solvents.
  • Touchscreen: Use a microfiber cloth specifically designed for electronic screens. Do not apply excessive pressure.
  • Fiber Optic Ports: Regularly clean the OTDR and iOLM ports using approved fiber optic cleaning sticks and solutions to prevent contamination and ensure accurate measurements. Refer to industry best practices for fiber cleaning.

6.2 Battery Care

  • To maximize battery life, avoid fully discharging the lithium-polymer battery frequently.
  • Store the device in a cool, dry place when not in use for extended periods.
  • If storing for a long time, ensure the battery is charged to approximately 50%.

6.3 Software Updates

Periodically check the EXFO website for firmware updates to ensure your device has the latest features and performance enhancements. Updates can typically be installed via USB connection to a PC.

7. Troubleshooting

This section addresses common issues you might encounter with your MaxTester 710B-M1.

7.1 Device Not Powering On

  • Ensure the battery is sufficiently charged. Connect the device to the AC/DC adapter and try again.
  • Verify the power adapter and cable are securely connected and functioning correctly.

7.2 No OTDR Trace or Inaccurate Readings

  • Check Fiber Connection: Ensure the fiber under test is properly connected to the OTDR port and that connectors are clean.
  • Verify Launch Cable: If using a launch cable, ensure it is in good condition and properly connected.
  • Correct Parameters: Confirm that the selected wavelength, pulse width, and distance range match the fiber being tested.
  • Dirty Connectors: Contaminated fiber connectors are a common cause of poor readings. Clean all connectors thoroughly.

7.3 Touchscreen Unresponsive

  • Perform a soft reset by holding the power button until the device restarts.
  • Ensure the screen is clean and free from debris or moisture.

8. Specifications

The following table details the technical specifications of the EXFO MaxTester 710B-M1.

Technical Specifications for EXFO MaxTester 710B
A detailed table outlining the technical specifications of the MaxTester 710B.
FeatureSpecification
ModelMAXTESTER 710B
DisplayTouchscreen, Two USB 2.0 ports, RJ-45 LAN 10/100 Mbit/s
Storage2 GB internal memory (20 000 OTDR traces, typical)
BatteriesRechargeable lithium-polymer battery, 12 hours of operation (Telcordia TR-NWT-001138)
Power supplyAC/DC adapter, input 100-240 VAC, 50-60 Hz, 9-16 V DCIN 15 Watts minimum
Wavelength1310/1550nm
Dynamic range30/28dB
Event dead zone1m
Attenuation dead zone4m
Distance range0.1 to 160 km
Pulse width5 ns to 20 us
Linearity±0.05dB
Loss threshold0.01dB
Loss resolution0.001dB
Sampling resolution0.04 to 5m
Sampling pointsUp to 256 000
Fiber TypeSingle Mode
Connector TypeHybrid

9. User Tips

  • Understand Your Equipment: If you're new to OTDRs, take time to familiarize yourself with the device's functions and included accessories. The carrying case is designed for protection and portability.
  • Always Clean First: The most critical step for accurate fiber testing is ensuring all connectors are spotless. A single speck of dust can cause significant measurement errors.
  • Use iOLM for Simplicity: For quick and easy link characterization without deep OTDR trace analysis, leverage the iOLM feature. It provides clear, actionable results.
  • Regular Data Backup: Periodically transfer your saved traces and test results to a computer to prevent data loss and for comprehensive reporting.

10. Warranty and Support

For specific warranty information, technical support, or service inquiries, please refer to the official EXFO documentation included with your product or visit the EXFO website. Keep your proof of purchase and serial number handy when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.