PowMr POW-M25/M35/M45-PRO

Contents

PowMr MPPT Solar Charge Controller User Manual

Models: POW-M25-PRO, POW-M35-PRO, POW-M45-PRO

1. Product Introduction

Welcome to the POW-M series solar controllers, a forefront innovation in solar technology designed to provide exceptional performance and reliability for your solar system. Our meticulously designed controllers incorporate advanced digital control technology, featuring an LCD screen and user-friendly buttons to enhance configuration flexibility, allowing real-time monitoring of operational data and system status. Additionally, the controllers support Maximum Power Point Tracking (MPPT) battery charging mode, maximizing energy utilization efficiency.

The POW-M series solar controllers are engineered to meet diverse solar system requirements, whether in standalone systems or other application scenarios. They automatically control the battery charging and discharging processes, optimizing these operations to extend battery life and improve overall system performance. Equipped with self-detection and electronic protection functions, the controllers effectively prevent damage during installation errors or system malfunctions, ensuring system reliability and stability.

Our POW-M series solar controllers offer extensive expandability and customization options, streamlining the solar system configuration process. Whether you are building a standalone solar system or expanding a solar energy project, the POW-M series controllers will be an indispensable partner. Their compact size and lightweight design, combined with air-cooled and aluminum alloy backplate natural cooling technologies, enhance operational safety, stability, and suitability for various scenarios. The parallel function allows users to easily scale up their solar energy capacity.

The POW-M series solar controllers are available in 25A, 35A, and 45A charging current options, ensuring your solar system can efficiently capture and store energy. Whether you are seeking an efficient, sustainable, and secure energy management solution or providing robust support for future energy demands, the POW-M series solar controllers are your ideal choice. We are committed to advancing solar technology, offering you exceptional products and services to support your solar system construction.

PowMr MPPT Solar Controller with 25A, 35A, 45A Max Charge Current, 12V/24V Battery Voltage Range, 100VDC Max PV Input, and >99% PV Utilization.
PowMr MPPT Solar Controller overview, highlighting key specifications.

2. Important Safety Guidelines

Warning: Please carefully read and adhere to all safety instructions.

  • Before installing and operating the controller, carefully read the user manual and keep it stored safely for future reference.
  • Installation or operation of the controller is not permitted for the following individuals without strict guidance and supervision:
    • Anyone lacking the relevant knowledge, experience, or capability for safe installation and/or operation requirements.
    • Anyone with impaired or diminished physical, sensory, or intellectual capabilities that may affect safe installation and/or operation (including children).

Controller Installation and Operation Safety

  • This controller product has no user-serviceable parts. Do not dismantle or attempt to repair the controller.
  • Install the controller in an environment with good natural ventilation and ensure sufficient spacing around it.
  • Mount the controller on a non-flammable wall and ensure there are no flammable materials nearby; temperature elevation during controller operation is normal.
  • Install the controller in an environment free from direct sunlight, rainwater, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or place/operate the controller on top of or directly above batteries or in enclosed spaces containing batteries, as batteries release explosive gases.
  • Do not place any other items on top of the controller.

Battery Installation and Charging Safety

  • Install and charge batteries in a well-ventilated or exhaust environment.
  • Ensure there are no sources of ignition around the batteries, as they release explosive gases.
  • Battery acid is corrosive; if battery acid comes into contact with the skin, immediately rinse with clean water.
  • Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
  • Ensure the equipment is set up reasonably according to the connected battery type.

DC Battery Wiring Safety

  • Ensure all cables and/or new ports connecting to the battery/DC system are fully closed/disconnected in advance.
  • Use flexible multi-strand copper cables with appropriate cross-sectional areas and connect them to matching fuses or circuit breakers.
  • It is prohibited to connect the solar array to the controller without the battery connected; priority must be given to connecting the battery.

3. Product Appearance

Diagram of PowMr MPPT Solar Charge Controller showing LCD display, function buttons, PV input, battery interface, load interface, port cover, heat sink, and mounting holes.
Product overview with labeled components.
Component Identification
No.ComponentNo.Component
1LCD Display5Load Interface
2Function Buttons6Port Cover
3PV Input Interface7Heat Sink
4Battery Interface8Mounting Holes

4. Setup (Installation and Wiring)

4.1 Unboxing and Inspection

Before unboxing, check if the packaging is damaged. After unboxing, inspect the contents for any damage or missing items. Inside the package, you will find:

  • Controller
  • User Manual
  • Dedicated Mounting Screws
  • Installation Guide Card

4.2 Selecting Installation Location

Before installation, consider the following aspects to determine/provide a suitable and safe installation location:

  • Install the controller in a space with good natural ventilation/exhaust.
  • Avoid direct sunlight.
  • Ensure there is sufficient clearance around the controller. The minimum clearance for the top, bottom, and sides of the controller is 75mm.
  • Mount the controller on a non-flammable wall and ensure there are no flammable materials nearby; temperature elevation during controller operation is normal.
  • Install the controller in an environment free from direct sunlight, rainwater, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or place/operate the controller on top of the battery, directly above it, or in an enclosed space where the battery is located, as the battery may release explosive gases.

4.3 Wiring Precautions

  1. Installation and wiring should be carried out by a certified electrician.
  2. Follow this sequence when wiring: Battery > PV Input > DC Output.
  3. To avoid short circuits and reverse polarity, ensure that the positive (+) cable is connected to the positive (+) terminal of the equipment and the negative (-) cable to the negative (-) terminal.
  4. Undersized or loose connections can cause cables or terminals to overheat. Therefore, tighten all cables to minimize transitional resistance. Use cables of appropriate size according to the current of the specific circuit.

4.4 Installation and Wiring Guide

Step 1. Mounting the Controller: Install the controller vertically with the ports facing downward. Secure it to the wall using screws through the four mounting holes on the body. For easier installation, it is recommended to "hang" the equipment using the two upper screws first, then add the two lower screws, and finally secure all four screws completely.

Schematic Wiring Diagram for PowMr MPPT Solar Charge Controller, showing connection order: Battery, Load, then PV Array.
Schematic Wiring Diagram and connection order.

Step 2. Battery Wiring: Connect the battery to the controller using cables.

NOTICE:

  • If an inverter needs to be connected, please refer to the diagram below.
2 Step Easy Connection diagram for PowMr MPPT Solar Charge Controller, showing wiring of battery, solar panels, and DC load.
Detailed 2-step connection process.

NOTICE:

  • All wiring work must be performed by professionals.
  • For safe operation and proper application, corresponding breakers must be installed on the cables connected to the controller, and ensure all connections are tight.
  • Ensure all breakers are in the OFF position before completing all wiring.
  • Connect the positive cable terminal to the positive port and the negative cable terminal to the negative port.
  • The above precautions also apply to PV ports and DC output ports.

Step 3. PV Wiring: Connect the PV array to the controller using cables.

Step 4. DC Output Wiring: Connect the load to the controller using cables.

Step 5. Pre-start Check: Refer to the wiring diagram. If all connections are accurate and secure, close the battery and PV array breakers in sequence.

WARNING: Risk of electric shock!

  • Ensure all power sources are off before wiring, and follow appropriate inspection and operation procedures.

Video: Unboxing and basic wiring demonstration for the PowMr MPPT Solar Charge Controller.

5. Operating Guide

5.1 Button Introduction

LCD Screen display with indicators for Day/Night, Battery Power, Operation Mode, Load Status, PV Input, Battery Voltage/Charging Current/Temperature, and Load Operation Mode.
Backlight LCD Screen and its indicators.
LCD Display Indicators
No.Function
①Day/Night Indicator
②Indicates remaining battery power.
③Operation mode (see "5.3 Operation Mode Description").
④Load periodic operation status and alert status (see "7.2 Troubleshooting").
⑤Indicates PV input voltage/power.
⑥Indicates current battery voltage/charging current/device temperature/battery calibration voltage/battery type/boost charging voltage/float charging voltage/DC under-voltage recovery voltage/DC under-voltage cutoff voltage.
⑦Indicates load operation mode.

5.2 Key Introduction

Function Keys
Function KeyDescription
PV / □Browsing Mode: Switches PV input parameter information
BAT/▲Browsing Mode: Short press to switch battery information (to the next option). Long press to enter battery parameter settings.
Setup Mode: Increases the value.
DC/▼Browsing Mode: Switches battery information (to the previous option). Long press to enter load operation mode settings.
Setup Mode: Decreases the value.
SET / ⚙Short Press: Confirms and saves settings.
Long Press: Restores factory settings.

5.3 Operation Mode Description

Operation Modes
CodeDescription
3.0Night mode, not charging
4.0Fast charging mode (MPPT mode)
7.0Boost charging mode
8.0Float charging mode

Note: In case of a fault, the operation mode section will display the fault code. For details, please refer to section 7.2 Troubleshooting.

5.4 Overview of PV Parameters

Short press the PV / □ button, and the data on the left side of the screen will switch between PV input voltage and power.

5.5 Battery Parameters Overview and Settings

In browse mode, use the BAT/▲ and DC/▼ keys to scroll through the battery parameters. When you reach the parameter you want to set, long press the BAT/▲ key to enter parameter setting mode. Once in the specified parameter setting, adjust the value size or toggle options using the BAT/▲ and DC/▼ keys, then press the SET / ⚙ key to confirm the settings.

Diagram showing compatibility with multiple battery types (AGM, GEL, FLD, LI, SLA) and instructions for setting battery type.
Battery type compatibility and setting instructions.

Battery Type Selection

Please select the battery type according to the table below based on the connected battery:

Battery Type Options
SequenceDisplayBattery Type
1SELSealed lead-acid battery
2GELGel sealed lead-acid battery
3FLdFlooded lead-acid battery
4L044S Lithium iron phosphate battery
5L077S Lithium iron phosphate battery
6L088S Lithium iron phosphate battery
7N033S Lithium-ion battery
8N066S Lithium-ion battery
9N077S Lithium-ion battery
10USEUser-defined

Long press the BAT/▲ key to enter the setting program. Use the BAT/▲ and DC/▼ keys to toggle through the battery type options, then press the SET / ⚙ key to save and confirm. If you select User-defined battery type, you can proceed with setting the following battery parameters.

Custom Configuration of Charging Voltage

If the battery type is set to "USE" (User-defined mode), you can manually adjust the following 5 charging parameters. If "USE" is not selected, manual adjustment of charging parameters is not required. The controller will charge based on preset values corresponding to the battery type. Refer to section 5.6 for preset charging values.

  • System Voltage Setting Interface: System voltage options: 12V/24V.
  • Boost Charging Voltage Setting Interface: Default: 14.4V, adjustable range: 9.0~17.0V, step size: 0.1V.
  • Float Charging Voltage Setting Interface: Default: 13.8V, adjustable range: 9.0~17.0V, step size: 0.1V.
  • Under-voltage Recovery Voltage Setting Interface: Default: 12.6V, adjustable range: 9.0~17.0V, step size: 0.1V.
  • Under-voltage Cut-off Voltage Setting Interface: Default: 11.0V, adjustable range: 9.0~17.0V, step size: 0.1V.

5.6 Default Parameters for Different Battery Types

For Lead-acid Batteries and User-defined Batteries:

Lead-acid/User-defined Battery Parameters
Battery TypeFLdGELSELUSE
Boost Charge Voltage14.6V14.2V14.4V9.0~17.0V
Float Charge Voltage13.8V13.8V13.8V9.0~17.0V
Low Voltage Cutoff Voltage11.0V11.0V11.0V9.0~17.0V
Low Voltage Recovery Voltage12.6V12.6V12.6V9.0~17.0V

For Lithium-Ion Batteries:

Lithium-Ion Battery Parameters
Battery TypeN03N06N07
Boost Charge Voltage12.5V25.0V29.2V
Float Charge Voltage12.2V24.4V28.5V
Low Voltage Cutoff Voltage8.4V16.8V19.6V
Low Voltage Recovery Voltage9.0V18.0V21.0V

For LiFePO4 Batteries:

LiFePO4 Battery Parameters
Battery TypeL04L07L08
Boost Charge Voltage14.5V25.4V29.0V
Float Charge Voltage13.8V24.1V27.6V
Low Voltage Cutoff Voltage11.2V19.6V22.4V
Low Voltage Recovery Voltage12.0V21.0V24.0V

NOTICE:

  • The charging parameters for lead-acid and user-defined batteries in the above table are based on a 12V system voltage. For 24V system voltage, multiply these values by 2. Similarly, for lead-acid or user-defined battery types with a system voltage of 24V, the actual charging voltage will be twice the displayed voltage on the monitor.

5.7 Charging Stages

Three stages of lead-acid battery charging:

Graph showing three stages of lead-acid battery charging: Bulk, Boost, and Float, with corresponding voltage and current curves.
Lead-acid battery charging stages.

Two stages of lithium battery charging:

Graph showing two stages of lithium battery charging: Bulk and Boost, with corresponding voltage and current curves.
Lithium battery charging stages.

6. Maintenance

We recommend conducting the following checks and maintenance at least twice a year to ensure optimal performance:

  1. Ensure the controller is securely mounted in a clean and dry environment.
  2. Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
  3. Inspect all exposed wires for insulation damage, such as severe sun exposure, friction wear, dryness, insect or rodent damage. Repair or replace any damaged wires as necessary.
  4. Tighten all terminals and check for loose, broken, or burnt cable connections.
  5. Confirm that all system components are properly grounded.
  6. Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
  7. Check for dirt, nesting insects, and corrosion. If present, clean promptly.

WARNING: Risk of electric shock!

  • Before performing the above operations, ensure that all power sources are turned off and then follow the relevant check and operation guidelines.

7. Troubleshooting

7.1 Protection Functions

Diagram illustrating 9 built-in protection features of the PowMr MPPT Solar Controller: PV over current, PV short circuit, PV reverse polarity, Battery reverse polarity, Battery over voltage, Battery over discharge, Lithium battery low temperature, Load overcurrent protection, Overtemperature.
Built-in Protection Features.
Protection Functions Overview
ProtectionDescription
Photovoltaic array short circuitWhen a short circuit occurs in the photovoltaic array, the controller will cease charging. Rectifying the short circuit fault will restore operation.
Photovoltaic input overcurrentThe controller limits the battery charging current to the maximum rated value. Therefore, an overcurrent from the photovoltaic array will prevent operation at peak power.
Load overcurrent protectionWhen the load current reaches its rated value, the controller automatically shuts down the DC output. It will recheck the output after 5 minutes to detect if overcurrent persists.
Photovoltaic polarity reversalIf the photovoltaic wiring polarity is reversed, the controller will not operate. Correct connection is necessary to restore normal operation.
Battery polarity reversalSimilarly, if the battery wiring polarity is reversed, the controller will not function until correct connection is restored.
OvertemperatureWhen the controller's heatsink temperature exceeds 65°C, it automatically begins reducing the charging current. If it exceeds 80°C, the controller shuts down automatically.

7.2 Troubleshooting

When a fault occurs, the controller will display a fault signal to assist you in identifying solutions.

LCD Screen display showing error code 63, indicating a fault. Table lists fault codes, causes, and solutions.
Example of fault display and troubleshooting table.
Fault Codes and Solutions
Fault CodeFault CauseSolution
18Input photovoltaic voltage too lowIncrease the number of solar panels or connect them in series to raise the photovoltaic input voltage.
60Overtemperature protectionAllow the equipment to cool to below the recovery temperature to resume normal charging and discharging.
63Battery voltage too highMeasure to confirm if battery voltage exceeds rated voltage and disconnect photovoltaic array circuit breaker.
65Battery voltage too lowCharge the battery until voltage exceeds the undervoltage recovery point. Refer to "5.6 Default Parameters for Different Battery Types" for specific details.
71Input photovoltaic voltage too highReduce the number of photovoltaic arrays connected to the controller to lower photovoltaic input; or adjust series and parallel connections to reduce voltage or current values.
73Overcharging currentReduce output terminal load to ensure total load is within rated limits of the controller and battery.
72Overdischarging currentReduce output terminal load to ensure total load is within rated limits of the controller and battery.

8. Specifications

PowMr MPPT Solar Charge Controller Specifications
Models25A35A45A
Solar Input Parameters
Max. PV Open-Circuit Voltage100V
Max. Input Power:
For 12V System300W420W540W
For 24V System600W840W1080W
Input Voltage Range:
For 12V System<60V<80V<100V
For 24V System<60V<80V<100V
Battery Charging Parameters
Charging TechnologyMPPT
Charging Algorithm3 Stages
Nominal System Voltage12V/24V
Battery Voltage Range9~30V
Rated Charging Current25A35A45A
Conversion Efficiency≤98%
Max. Power Point Tracking Efficiency>99%
Temperature Compensation-3mV/°C/2V (default)
Self-Consumption44mA/12V; 26mA/24V
DC Output Parameters
Rated DC Output Current15A20A25A
General Parameters
IP ClassIP32
Operating Temperature Range-35°C~+45°C
Humidity Range≤95% Non-condensing
Altitude<3000m
Dimensions160x115x51mm195x135x65mm195x135x65mm
Net Weight500g900g1035g

9. User Tips

  • Regular Checks: Periodically inspect all wiring connections for tightness and signs of wear or corrosion to ensure optimal performance and safety.
  • Ventilation is Key: Always ensure the controller is installed in a well-ventilated area with sufficient clearance to prevent overheating, which can reduce efficiency and lifespan.
  • Battery Type Matching: Double-check that the battery type setting on the controller accurately matches your connected battery to prevent improper charging and potential damage.
  • Monitor Performance: Utilize the LCD display to regularly monitor PV input, battery voltage, and charging current to ensure your solar system is operating efficiently.

10. Warranty and Support

10.1 Disclaimer

In any of the following circumstances, our company reserves the right to disclaim liability for quality assurance:

  • Damage caused by improper transportation.
  • Damage resulting from incorrect storage, installation, or usage.
  • Damage caused by non-professionals or untrained personnel installing and using the equipment.
  • Damage resulting from failure to adhere to the instructions and safety warnings in this document.
  • Damage caused by operation in environments not meeting the requirements specified in this document.
  • Damage resulting from operation beyond the parameters specified in the applicable technical specifications.
  • Damage caused by unauthorized dismantling, alteration of the product, or modification of software code.
  • Damage caused by exceptional natural circumstances (force majeure), such as lightning, earthquakes, fires, storms, etc.
  • Any damage resulting from failure to follow local standards and regulations during installation and operation processes.
  • Products beyond the warranty period.

10.2 Contact Information

For technical support or inquiries, please contact:

  • Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China