1. Introduction
The SRNE HYP series is an all-in-one hybrid solar charge inverter designed for solar energy storage and AC sine wave output. It integrates solar charging, energy storage, and AC output functionalities. Utilizing DSP control and an advanced control algorithm, this inverter offers high response speed, reliability, and meets industrial standards.
It supports four charging modes: Only Solar, Mains Priority, Solar Priority, and Mains & Solar hybrid charging. Two output modes are available: Inverter and Mains, catering to diverse application requirements.
The solar charging module incorporates optimized MPPT technology for rapid tracking of the maximum power point of the PV array, ensuring real-time maximum energy harvesting from solar panels.
The AC-DC charging module features a state-of-the-art control algorithm, enabling fully digital voltage and current double closed-loop control, with high precision in a compact design. It offers a wide AC voltage input range and comprehensive input/output protections for stable and reliable battery charging.
The DC-AC inverter module, based on a full-digital intelligent design, uses advanced SPWM technology to produce a pure sine wave output, converting DC to AC. This makes it suitable for various AC loads, including household appliances, power tools, industrial equipment, and audio/video systems. The product includes a segment LCD for real-time display of system data and operating status, along with comprehensive electronic protections for enhanced safety and stability.

Image: Front view of the SRNE HYP4860S100-H Hybrid Solar Inverter, showing the LCD screen and control buttons.
2. Key Features
- Anti-backflow grid connection function, supporting inverter and mains power hybrid output.
- Can operate without a battery under special conditions and supports on-grid power generation settings.
- Two output modes: mains bypass and inverter output, ensuring uninterrupted power supply.
- Two charging modes: Only Solar and Mains & Solar hybrid charging.
- Advanced MPPT technology with an efficiency of 99.9%.
- LCD screen and 3 LED indicators for dynamic display of system data and operating status.
- Time slot control function to prioritize mains or battery usage based on local peak and valley tariffs.
- Power saving mode to reduce no-load loss.
- Intelligent variable speed fan for efficient heat dissipation and extended system life.
- Lithium battery activation via PV solar or mains, compatible with lead-acid and lithium batteries.
- 360° all-around protection with multiple safety functions.
- Complete protections including short circuit, over/under voltage, overload, and reverse protection.
- Support for WIFI Module for remote monitoring and control.
- Max Parallel 6 Units for scalable power solutions.

Image: Diagram highlighting key features of the SRNE HYP series, including advanced MPPT, parallel capability, time-slot function, off-grid/battery-less operation, industrial design, and BMS communication support.
3. Product Overview
The SRNE HYP4860S100-H inverter is designed for robust performance and ease of use. Below is an overview of its components and typical system integration.

Image: System overview diagram showing the HYP series inverter connected to a PV array, generator or utility, external battery packs, and various home appliances.
3.1 Component Identification

Image: Detailed diagram of the inverter's front and rear panels with numbered components.
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | Indicator light | 10 | Dry contact port |
| 2 | LCD screen | 11 | WIFI communication port |
| 3 | Touchablen key | 12 | Parallel communication A/B port |
| 4 | Grid input port | 13 | CAN communication port |
| 5 | Generator input port | 14 | Grounding |
| 6 | Load port | 15 | USB communication port |
| 7 | PV1/PV2 port | 16 | RS485 communication port |
| 8 | Cooling fan | 17 | ON/OFF rocker switch |
| 9 | Battery port | 18 | Overload protector |
4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your SRNE HYP4860S100-H inverter. Ensure all connections are secure and follow local electrical codes and safety guidelines.
4.1 Parallel Connection
The HYP4860S100-H supports parallel operation for increased power output, up to 6 units for a total of 36kW. Below are schematic diagrams for parallel connections. Always ensure proper wiring and communication setup when connecting multiple units.
4.1.1 Two Inverters in Parallel

Image: Wiring diagram for two all-in-one solar charger inverters connected in parallel, showing connections to battery, utility grid, and loads, along with communication lines.
4.1.2 Three Inverters in Parallel

Image: Wiring diagram for three all-in-one solar charger inverters connected in parallel, detailing battery, grid, load, and communication connections.
4.1.3 Four Inverters in Parallel

Image: Wiring diagram for four all-in-one solar charger inverters connected in parallel, illustrating the expanded system with battery, grid, load, and communication links.
Important Note: The battery capacity of the correct matching system is determined according to the specific usage requirements of the load and application scenarios. Incorrect sizing can lead to insufficient battery capacity or excessive waste of power generation. For optimal performance and safety, please refer to the detailed manual recommendations or consult with qualified technical support.
5. Operating Instructions
5.1 Charging Modes
The inverter offers flexible charging options, configurable via the LCD screen:
- Only Solar: Charging is exclusively from the solar PV array.
- Mains Priority: Utility grid power is prioritized for charging the battery.
- Solar Priority: Solar power is prioritized for charging, with the utility grid acting as a backup source.
- Mains & Solar Hybrid Charging: Combines both utility grid and solar power for battery charging.
5.2 Output Modes
Select between the following output modes:
- Inverter Mode: Power is supplied from the battery (charged by solar/mains) and/or directly from solar to the loads.
- Mains Bypass Mode: Loads are directly powered by the utility grid, bypassing the inverter's power conversion.
5.3 Time-Slot Setting Function
Utilize the time-slot control function to optimize energy usage based on local peak and valley tariffs. This allows you to set priorities for using mains or battery power during specific times, potentially leading to cost savings. Refer to the detailed manual for configuration steps.
5.4 Power Saving Mode
Activate the power saving mode to reduce no-load loss, improving overall system efficiency when the inverter is not under significant load. This feature helps conserve battery power.
5.5 LCD Display and Indicators
The LCD screen and three LED indicators provide real-time system data and operating status. Refer to Section 3.1 for component identification and their respective functions. The touchable keys allow for navigation and setting adjustments.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources (PV, battery, grid) before performing any maintenance.
- Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are not obstructed to allow for proper airflow.
- Cooling Fans: The intelligent variable speed fans efficiently dissipate heat. Periodically check that they are not blocked and operate correctly. Excessive noise or lack of fan operation may indicate an issue requiring inspection.
- Connections: Periodically check all electrical connections (PV, battery, grid, load, communication) for tightness and signs of corrosion. Loose connections can lead to poor performance or safety hazards.
- Battery Health: Monitor battery voltage and health, especially for lead-acid batteries. Ensure proper charging cycles are maintained. The inverter supports lithium battery activation, which may require specific monitoring procedures.
- Environment: Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, excessive moisture, and flammable materials. Maintain the recommended operating temperature range.
7. Troubleshooting and Protections
The inverter is equipped with comprehensive protection functions to ensure system safety and stability. The LCD screen will display error codes or messages in case of an issue. Consult the detailed user manual for specific error code interpretations and troubleshooting steps.
7.1 Protection Functions
- Short Circuit Protection: Protects against short circuits in the output circuitry.
- Over Voltage and Under Voltage Protection: Safeguards against input/output voltage fluctuations outside safe operating limits, protecting connected equipment and the inverter itself.
- Overload Protection: The inverter implements a tiered overload protection system:
- (102% < load < 125%) ±10%: Reports an error and turns off the output after 5 minutes.
- (125% < load < 150%) ±10%: Reports an error and turns off the output after 10 seconds.
- Load > 150% ±10%: Reports an error and turns off the output after 5 seconds.
- Reverse Protection: Protects against incorrect polarity connections for battery and PV inputs.
- AC Reverse Protection: Prevents reverse current flow from the inverter to the AC input (utility grid).
- Overcharge Protection: Alarms and turns off charging after 1 minute if battery overcharge is detected, preventing battery damage.
- PV Wiring Protection: Includes reverse polarity protection for PV input connections.
If an error occurs, consult the LCD display for specific error codes and refer to the full user manual for detailed troubleshooting steps. Ensure all power sources are disconnected before attempting any inspection or repair.
8. Technical Specifications
Below are the detailed technical specifications for the SRNE HYP4860S100-H Hybrid Solar Inverter. These specifications are subject to change without prior notice.

Image: Comprehensive table detailing the technical specifications of the inverter.
| Specification Category | Value | |
|---|---|---|
| MODEL | HYP4860S100-H | |
| Parallel mode | ||
| Permitted parallel number | 1~6 | |
| AC mode | ||
| Rated input voltage | 220/230Vac | |
| Input voltage range | (170Vac~280Vac) ±2% (90Vac-280Vac) ±2% | |
| Frequency | 50Hz/ 60Hz (Auto detection) | |
| Frequency Range | 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz); | |
| Overload/short circuit protection | Circuit breaker | |
| Efficiency | >95% | |
| Conversion time (bypass and inverter) | 10ms (typical) | |
| AC reverse protection | Available | |
| Maximum bypass overload current | 40A | |
| Inverter mode | ||
| Output voltage waveform | Pure sine wave | |
| Rated output power (VA) | 6200 | |
| Rated output power (W) | 6200 | |
| Power factor | 1 | |
| Rated output voltage (Vac) | 230Vac (200/208/220/240Vac Settable) | |
| Output voltage error | ±5% | |
| Output frequency range(Hz) | 50Hz ± 0.3Hz 60Hz ± 0.3Hz | |
| Maximum Efficiency | >92% | |
| Overload protection | (102% < load <125%) ±10%: report error and turn off the output after 5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds; | |
| Peak power | 12400VA | |
| Loaded motor capability | 5HP | |
| Rated battery input voltage | 48V (Minimum starting voltage 44V) | |
| Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen) | |
| Power saving mode self-consumption | Load≤50W | |
| AC Output (Grid) | ||
| Rated Output Power (W) | 6200W | |
| Max. apparent power (VA) | 6200VA | |
| Max. output current (A) | 27A | |
| THDI | <3% | |
| Rated voltage(V) | 230Vac | |
| Frequency | 50Hz/60Hz | |
| AC charging | ||
| Battery type | Lead acid or lithium battery | |
| Maximum charge current (can be set) | 0-80A | |
| Charge current error | ± 3Adc | |
| Charge voltage range | 40 –58Vdc | |
| Short circuit protection | Circuit breaker and blown fuse | |
| Circuit breaker specifications | 40A | |
| Overcharge protection | Alarm and turn off charging after 1 minute | |
| PV charging | ||
| Maximum PV open circuit voltage | 550Vdc | |
| PV operating voltage range | 120-480Vdc | |
| MPPT voltage range | 120-480Vdc | |
| Battery voltage range | 40-60Vdc | |
| Maximum PV input power | 4500W+4500W | |
| Maximum PV input current | 18A+18A | |
| PV charging current range (can be set) | 0~100A | |
| Charging short circuit protection | Blown fuse | |
| Wiring protection | Reverse polarity protection | |
| Hybrid charging Max charger current specifications (AC charger+PV charger) | ||
| Max charger current (can be set) | 100A | |
| Certified specifications | ||
| Certification | EN 62109-1, EN 62109-2, NRS097-2-1 | |
| EMC certification level | EN IEC61000-6-3 | |
| Operating temperature range | -10°C to 55°C | |
| Storage temperature range | -25°C ~ 60°C | |
| Humidity range | 5% to 95% (Conformal coating protection) | |
| Noise | ≤60dB | |
| Heat dissipation | Forced air cooling, variable speed of fan | |
| Communication interface | USB/RS485(WiFi/GPRS)/Dry contact control | |
| Dimension (L*W*D) | 510mm*350mm*133mm | |
| Weight | 13KG | |
9. WIFI Module and App
The SRNE HYP4860S100-H inverter supports a WIFI module for remote monitoring and control via a smartphone application. This allows users to conveniently manage their solar power system from anywhere.
9.1 WIFI Module Overview

Image: The SRNE WIFI module, connection cable, and mounting hardware included for installation.

Image: Close-up of the SRNE WIFI module, showing its serial number and a QR code for initial setup or registration.
9.2 SOLARMANTM Smart App
To utilize the WIFI module, download and install the SOLARMANTM Smart App on your smartphone. The app provides an intelligent energy management interface for monitoring and controlling your inverter.

Image: QR code for downloading the SOLARMANTM Smart App. Scan this code with your smartphone to access the app store or download link.

Image: Preview of the SOLARMANTM Smart App interface, showcasing its energy management features and user-friendly design.
Follow the instructions provided with the WIFI module for pairing and setup with the SOLARMANTM Smart App. Ensure your smartphone has an active internet connection during the setup process.
10. Warranty and Support
The SRNE HYP4860S100-H Hybrid Solar Inverter comes with a 2-year warranty, ensuring reliability and peace of mind. For specific warranty terms and conditions, please refer to the official warranty document provided with your purchase or contact SRNE customer support.
10.1 Certifications
This product is certified to meet international standards for safety and electromagnetic compatibility, ensuring its quality and compliance.

Image: Certificates for UKCA, CE, and RoHS compliance, indicating adherence to European and UK safety and environmental standards.
- Certification: EN 62109-1, EN 62109-2, NRS097-2-1
- EMC Certification Level: EN IEC61000-6-3
10.2 Customer Support
For technical assistance, troubleshooting, or warranty claims, please contact your local dealer or SRNE customer support. Have your model number (HYP4860S100-H) and purchase details ready when contacting support to expedite the process.