SRNE HYP4860S100-H

Contents

SRNE HYP4860S100-H 6.2KW Hybrid Solar Inverter Instruction Manual

Model: HYP4860S100-H

1. Introduction

The SRNE HYP series is an all-in-one hybrid solar charge inverter designed for solar energy storage and AC sine wave output. It integrates solar charging, energy storage, and AC output functionalities. Utilizing DSP control and an advanced control algorithm, this inverter offers high response speed, reliability, and meets industrial standards.

It supports four charging modes: Only Solar, Mains Priority, Solar Priority, and Mains & Solar hybrid charging. Two output modes are available: Inverter and Mains, catering to diverse application requirements.

The solar charging module incorporates optimized MPPT technology for rapid tracking of the maximum power point of the PV array, ensuring real-time maximum energy harvesting from solar panels.

The AC-DC charging module features a state-of-the-art control algorithm, enabling fully digital voltage and current double closed-loop control, with high precision in a compact design. It offers a wide AC voltage input range and comprehensive input/output protections for stable and reliable battery charging.

The DC-AC inverter module, based on a full-digital intelligent design, uses advanced SPWM technology to produce a pure sine wave output, converting DC to AC. This makes it suitable for various AC loads, including household appliances, power tools, industrial equipment, and audio/video systems. The product includes a segment LCD for real-time display of system data and operating status, along with comprehensive electronic protections for enhanced safety and stability.

SRNE HYP4860S100-H Hybrid Solar Inverter

Image: Front view of the SRNE HYP4860S100-H Hybrid Solar Inverter, showing the LCD screen and control buttons.

2. Key Features

  • Anti-backflow grid connection function, supporting inverter and mains power hybrid output.
  • Can operate without a battery under special conditions and supports on-grid power generation settings.
  • Two output modes: mains bypass and inverter output, ensuring uninterrupted power supply.
  • Two charging modes: Only Solar and Mains & Solar hybrid charging.
  • Advanced MPPT technology with an efficiency of 99.9%.
  • LCD screen and 3 LED indicators for dynamic display of system data and operating status.
  • Time slot control function to prioritize mains or battery usage based on local peak and valley tariffs.
  • Power saving mode to reduce no-load loss.
  • Intelligent variable speed fan for efficient heat dissipation and extended system life.
  • Lithium battery activation via PV solar or mains, compatible with lead-acid and lithium batteries.
  • 360° all-around protection with multiple safety functions.
  • Complete protections including short circuit, over/under voltage, overload, and reverse protection.
  • Support for WIFI Module for remote monitoring and control.
  • Max Parallel 6 Units for scalable power solutions.
SRNE HYP series features diagram

Image: Diagram highlighting key features of the SRNE HYP series, including advanced MPPT, parallel capability, time-slot function, off-grid/battery-less operation, industrial design, and BMS communication support.

3. Product Overview

The SRNE HYP4860S100-H inverter is designed for robust performance and ease of use. Below is an overview of its components and typical system integration.

SRNE HYP4860S100-H Inverter System Overview

Image: System overview diagram showing the HYP series inverter connected to a PV array, generator or utility, external battery packs, and various home appliances.

3.1 Component Identification

SRNE HYP4860S100-H Inverter Ports and Indicators

Image: Detailed diagram of the inverter's front and rear panels with numbered components.

No.ComponentNo.Component
1Indicator light10Dry contact port
2LCD screen11WIFI communication port
3Touchablen key12Parallel communication A/B port
4Grid input port13CAN communication port
5Generator input port14Grounding
6Load port15USB communication port
7PV1/PV2 port16RS485 communication port
8Cooling fan17ON/OFF rocker switch
9Battery port18Overload protector

4. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your SRNE HYP4860S100-H inverter. Ensure all connections are secure and follow local electrical codes and safety guidelines.

4.1 Parallel Connection

The HYP4860S100-H supports parallel operation for increased power output, up to 6 units for a total of 36kW. Below are schematic diagrams for parallel connections. Always ensure proper wiring and communication setup when connecting multiple units.

4.1.1 Two Inverters in Parallel

Schematic diagram of two SRNE inverters connected in parallel

Image: Wiring diagram for two all-in-one solar charger inverters connected in parallel, showing connections to battery, utility grid, and loads, along with communication lines.

4.1.2 Three Inverters in Parallel

Schematic diagram of three SRNE inverters connected in parallel

Image: Wiring diagram for three all-in-one solar charger inverters connected in parallel, detailing battery, grid, load, and communication connections.

4.1.3 Four Inverters in Parallel

Schematic diagram of four SRNE inverters connected in parallel

Image: Wiring diagram for four all-in-one solar charger inverters connected in parallel, illustrating the expanded system with battery, grid, load, and communication links.

Important Note: The battery capacity of the correct matching system is determined according to the specific usage requirements of the load and application scenarios. Incorrect sizing can lead to insufficient battery capacity or excessive waste of power generation. For optimal performance and safety, please refer to the detailed manual recommendations or consult with qualified technical support.

5. Operating Instructions

5.1 Charging Modes

The inverter offers flexible charging options, configurable via the LCD screen:

  • Only Solar: Charging is exclusively from the solar PV array.
  • Mains Priority: Utility grid power is prioritized for charging the battery.
  • Solar Priority: Solar power is prioritized for charging, with the utility grid acting as a backup source.
  • Mains & Solar Hybrid Charging: Combines both utility grid and solar power for battery charging.

5.2 Output Modes

Select between the following output modes:

  • Inverter Mode: Power is supplied from the battery (charged by solar/mains) and/or directly from solar to the loads.
  • Mains Bypass Mode: Loads are directly powered by the utility grid, bypassing the inverter's power conversion.

5.3 Time-Slot Setting Function

Utilize the time-slot control function to optimize energy usage based on local peak and valley tariffs. This allows you to set priorities for using mains or battery power during specific times, potentially leading to cost savings. Refer to the detailed manual for configuration steps.

5.4 Power Saving Mode

Activate the power saving mode to reduce no-load loss, improving overall system efficiency when the inverter is not under significant load. This feature helps conserve battery power.

5.5 LCD Display and Indicators

The LCD screen and three LED indicators provide real-time system data and operating status. Refer to Section 3.1 for component identification and their respective functions. The touchable keys allow for navigation and setting adjustments.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources (PV, battery, grid) before performing any maintenance.

  • Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are not obstructed to allow for proper airflow.
  • Cooling Fans: The intelligent variable speed fans efficiently dissipate heat. Periodically check that they are not blocked and operate correctly. Excessive noise or lack of fan operation may indicate an issue requiring inspection.
  • Connections: Periodically check all electrical connections (PV, battery, grid, load, communication) for tightness and signs of corrosion. Loose connections can lead to poor performance or safety hazards.
  • Battery Health: Monitor battery voltage and health, especially for lead-acid batteries. Ensure proper charging cycles are maintained. The inverter supports lithium battery activation, which may require specific monitoring procedures.
  • Environment: Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, excessive moisture, and flammable materials. Maintain the recommended operating temperature range.

7. Troubleshooting and Protections

The inverter is equipped with comprehensive protection functions to ensure system safety and stability. The LCD screen will display error codes or messages in case of an issue. Consult the detailed user manual for specific error code interpretations and troubleshooting steps.

7.1 Protection Functions

  • Short Circuit Protection: Protects against short circuits in the output circuitry.
  • Over Voltage and Under Voltage Protection: Safeguards against input/output voltage fluctuations outside safe operating limits, protecting connected equipment and the inverter itself.
  • Overload Protection: The inverter implements a tiered overload protection system:
    • (102% < load < 125%) ±10%: Reports an error and turns off the output after 5 minutes.
    • (125% < load < 150%) ±10%: Reports an error and turns off the output after 10 seconds.
    • Load > 150% ±10%: Reports an error and turns off the output after 5 seconds.
  • Reverse Protection: Protects against incorrect polarity connections for battery and PV inputs.
  • AC Reverse Protection: Prevents reverse current flow from the inverter to the AC input (utility grid).
  • Overcharge Protection: Alarms and turns off charging after 1 minute if battery overcharge is detected, preventing battery damage.
  • PV Wiring Protection: Includes reverse polarity protection for PV input connections.

If an error occurs, consult the LCD display for specific error codes and refer to the full user manual for detailed troubleshooting steps. Ensure all power sources are disconnected before attempting any inspection or repair.

8. Technical Specifications

Below are the detailed technical specifications for the SRNE HYP4860S100-H Hybrid Solar Inverter. These specifications are subject to change without prior notice.

SRNE HYP4860S100-H Technical Specifications Table

Image: Comprehensive table detailing the technical specifications of the inverter.

Specification CategoryValue
MODELHYP4860S100-H
Parallel mode
Permitted parallel number1~6
AC mode
Rated input voltage220/230Vac
Input voltage range(170Vac~280Vac) ±2%
(90Vac-280Vac) ±2%
Frequency50Hz/ 60Hz (Auto detection)
Frequency Range47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protectionCircuit breaker
Efficiency>95%
Conversion time (bypass and inverter)10ms (typical)
AC reverse protectionAvailable
Maximum bypass overload current40A
Inverter mode
Output voltage waveformPure sine wave
Rated output power (VA)6200
Rated output power (W)6200
Power factor1
Rated output voltage (Vac)230Vac (200/208/220/240Vac Settable)
Output voltage error±5%
Output frequency range(Hz)50Hz ± 0.3Hz
60Hz ± 0.3Hz
Maximum Efficiency>92%
Overload protection(102% < load <125%) ±10%: report error and turn off the output after 5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds;
Peak power12400VA
Loaded motor capability5HP
Rated battery input voltage48V (Minimum starting voltage 44V)
Battery voltage rangeUndervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen)
Power saving mode self-consumptionLoad≤50W
AC Output (Grid)
Rated Output Power (W)6200W
Max. apparent power (VA)6200VA
Max. output current (A)27A
THDI<3%
Rated voltage(V)230Vac
Frequency50Hz/60Hz
AC charging
Battery typeLead acid or lithium battery
Maximum charge current (can be set)0-80A
Charge current error± 3Adc
Charge voltage range40 –58Vdc
Short circuit protectionCircuit breaker and blown fuse
Circuit breaker specifications40A
Overcharge protectionAlarm and turn off charging after 1 minute
PV charging
Maximum PV open circuit voltage550Vdc
PV operating voltage range120-480Vdc
MPPT voltage range120-480Vdc
Battery voltage range40-60Vdc
Maximum PV input power4500W+4500W
Maximum PV input current18A+18A
PV charging current range (can be set)0~100A
Charging short circuit protectionBlown fuse
Wiring protectionReverse polarity protection
Hybrid charging Max charger current specifications (AC charger+PV charger)
Max charger current (can be set)100A
Certified specifications
CertificationEN 62109-1, EN 62109-2, NRS097-2-1
EMC certification levelEN IEC61000-6-3
Operating temperature range-10°C to 55°C
Storage temperature range-25°C ~ 60°C
Humidity range5% to 95% (Conformal coating protection)
Noise≤60dB
Heat dissipationForced air cooling, variable speed of fan
Communication interfaceUSB/RS485(WiFi/GPRS)/Dry contact control
Dimension (L*W*D)510mm*350mm*133mm
Weight13KG

9. WIFI Module and App

The SRNE HYP4860S100-H inverter supports a WIFI module for remote monitoring and control via a smartphone application. This allows users to conveniently manage their solar power system from anywhere.

9.1 WIFI Module Overview

SRNE WIFI Module and accessories

Image: The SRNE WIFI module, connection cable, and mounting hardware included for installation.

SRNE WIFI Module with QR code

Image: Close-up of the SRNE WIFI module, showing its serial number and a QR code for initial setup or registration.

9.2 SOLARMANTM Smart App

To utilize the WIFI module, download and install the SOLARMANTM Smart App on your smartphone. The app provides an intelligent energy management interface for monitoring and controlling your inverter.

SOLARMAN Smart App QR code

Image: QR code for downloading the SOLARMANTM Smart App. Scan this code with your smartphone to access the app store or download link.

SOLARMAN Smart App interface preview

Image: Preview of the SOLARMANTM Smart App interface, showcasing its energy management features and user-friendly design.

Follow the instructions provided with the WIFI module for pairing and setup with the SOLARMANTM Smart App. Ensure your smartphone has an active internet connection during the setup process.

10. Warranty and Support

The SRNE HYP4860S100-H Hybrid Solar Inverter comes with a 2-year warranty, ensuring reliability and peace of mind. For specific warranty terms and conditions, please refer to the official warranty document provided with your purchase or contact SRNE customer support.

10.1 Certifications

This product is certified to meet international standards for safety and electromagnetic compatibility, ensuring its quality and compliance.

Product certifications for SRNE HYP4860S100-H

Image: Certificates for UKCA, CE, and RoHS compliance, indicating adherence to European and UK safety and environmental standards.

  • Certification: EN 62109-1, EN 62109-2, NRS097-2-1
  • EMC Certification Level: EN IEC61000-6-3

10.2 Customer Support

For technical assistance, troubleshooting, or warranty claims, please contact your local dealer or SRNE customer support. Have your model number (HYP4860S100-H) and purchase details ready when contacting support to expedite the process.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.