Introduction
This manual provides essential information for the safe and efficient use of your SUSWE S-1500W-12V Switching Power Supply. This AC-DC converter is designed for various applications requiring a stable 12V DC output from an AC input. Please read this manual thoroughly before installation and operation.
Safety Information
WARNING: Electrical shock hazard. Installation should only be performed by qualified personnel.
- Ensure the input voltage switch is correctly set (110V or 220V) before connecting to power to avoid damage.
- Always disconnect power before making any wiring connections or adjustments.
- Ensure proper grounding (Earth wire) to prevent electrical shock.
- Do not operate the power supply in wet or damp conditions.
- Ensure adequate ventilation to prevent overheating. The unit has a built-in cooling fan.
- The junction box has a protective cover to reduce dust and prevent accidental contact. Do not remove it during operation.


Specifications
| Attribute | Value |
|---|---|
| Brand Name | SUSWE |
| Type | Power Supply |
| Model | S-1500W-12V |
| Rated Capacity | 40-1000VA (includes 40VA) |
| Output Power | >500W (Specific model: 1500W) |
| Output Voltage | 12V |
| Output Current | 125A |
| Input Voltage | 110/220V±15% (selectable) |
| Output Frequency | DC |
| Output Type | SINGLE |
| Dimensions (L x W x H) | 24.0 cm x 13.0 cm x 7.0 cm |
| Weight | 2.2 kg |
| Certifications | CE, FCC, RoHS |
| High-concerned chemical | None |


Setup and Installation
- Input Voltage Selection: Locate the 110V/220V switch on the unit. Ensure it is set to the correct voltage for your region (e.g., 110V for USA) before connecting any power. Incorrect setting can damage the unit.

Image: Detail of the 110V/220V input voltage selection switch. Set to 110V for USA. - Wiring Connections: Refer to the wiring diagrams below for correct and safe connections.
Warm tips for wiring:
- AC: alternating current
- L: Live wire
- N: Connected to neutral line
- ⊥: Grounding casing (ground wire)
- +V: DC positive electrode
- -V: DC negative electrode

Image: Sample wiring diagram showing AC input (L, N, Earth) and DC output (+V, COM) terminals, along with the voltage adjustment screw (ADJ). 
Image: Detailed wiring diagrams for different power supply configurations (e.g., 12V 3A, 36V 10A, 48V 15A, 5V 2A) connecting to electric machinery, illustrating AC input and DC output connections. 
Image: Example wiring for a 5V 2A power supply, demonstrating how to connect AC input and DC output to an electrical load. - Secure Connections: Ensure all wires are securely fastened to the terminal blocks. The unit features a wiring protective cover for safety.

Image: View of internal components, including the wiring protective cover, fuse, pressure sensitive fuse, safety gauge capacitor, pure copper winding, work indicator, regulating voltage, and all aluminum housing.
Operating Instructions
- Power On: After ensuring all connections are correct and secure, connect the power supply to the AC mains. The LED indicator light will illuminate, showing the unit is operational.
- Output Voltage Adjustment: The output voltage can be finely adjusted using the potentiometer (labeled 'ADJ' or similar) located near the output terminals. Use a small screwdriver to carefully turn the potentiometer to achieve the desired output voltage. Monitor the voltage with a multimeter during adjustment.
Video: Demonstrates the voltage adjustment process using a screwdriver and multimeter, showing the output voltage changing and its effect on an LED strip. - Monitoring: The unit's Smart IC ensures voltage consistency and provides automatic protection features.
Maintenance
- Cleaning: Keep the power supply unit clean and free from dust. The dust protection design helps, but periodic cleaning of the exterior and ventilation openings is recommended to ensure optimal heat dissipation.
- Ventilation: Ensure the built-in cooling fan and ventilation holes are not obstructed. Proper airflow is crucial for maintaining stable performance and long service life, especially given the high temperature resistant capacitors.
- Inspection: Periodically check all wiring connections for tightness and signs of wear or damage.


Troubleshooting
The SUSWE power supply is equipped with multiple protection features to ensure safe and stable operation.
- No Output Power:
- Check if the AC input is correctly connected and receiving power.
- Verify the 110V/220V switch is set correctly.
- Ensure the LED indicator light is on. If not, check the fuse (visible in internal component image).
- Unstable Output Voltage:
- Check all wiring connections for looseness.
- Ensure the load is within the specified power limits.
- Verify the potentiometer (ADJ) is not accidentally moved.
- Unit Shuts Down:
- This could indicate activation of overload, overvoltage, or short circuit protection.
- Disconnect the load and power cycle the unit. If it powers on normally, the issue is with the load.
- Check for short circuits in the output wiring or the connected device.
- Reduce the load if it exceeds the power supply's capacity.
- Ensure proper ventilation to prevent thermal shutdown.


User Tips
- Power Sizing: For equipment with large starting power, such as motors, it is recommended to purchase a power supply with more than twice the required power to handle inrush currents and ensure reliable operation.
- Voltage Verification: Always use a multimeter to verify the output voltage after adjustment, especially when powering sensitive electronics.
- Application Versatility: This power supply is suitable for a wide range of applications including LED lighting, industrial control equipment, billboards, monitoring equipment, scientific research equipment, and medical equipment.

Warranty and Support
This SUSWE power supply is manufactured to high standards and is certified with CE, FCC, and RoHS, indicating compliance with relevant safety and environmental regulations.
For technical support, warranty claims, or further assistance, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.