DAXTROMN AGH-6.2KW-PRO

Contents

DAXTROMN AGH-6.2KW-PRO Hybrid Solar Inverter User Manual

6200W Hybrid Solar Inverter with 48V DC, 120A MPPT Solar Charger, 500V DC PV Input

1. Introduction

The DAXTROMN AGH-6.2KW-PRO is a versatile multi-function inverter/charger designed to provide uninterruptible power support. It integrates the functions of an inverter, a solar charger, and a battery charger into a compact and portable unit. This hybrid solar inverter is suitable for 48V systems and features a comprehensive LCD display for user-configurable operations, including battery charging current, AC/solar charger priority, and acceptable input voltage ranges. It also includes built-in WiFi for convenient monitoring and control.

2. Product Overview

The inverter's design allows for clear indication of status and data, with easy-to-access buttons for mode switching and parameter configuration. Below is a diagram illustrating the main components and their functions.

DAXTROMN AGH-6.2KW-PRO Hybrid Solar Inverter Product Overview with labeled components
Figure 2.1: Product Overview and Component Identification

Key Components:

  1. LCD Display: Shows system status, data, and settings.
  2. Status Indicator: Provides visual feedback on the inverter's operational status.
  3. Charging Indicator: Indicates the battery charging status.
  4. Fault Indicator: Lights up to signal system faults or errors.
  5. Function Buttons: Used for navigating menus and configuring settings.
  6. Power On/Off Switch: Controls the main power to the inverter.
  7. AC Input: Connection point for AC utility or generator power.
  8. Main Output: Primary AC output for connected loads.
  9. Second Output: Secondary AC output for additional loads.
  10. Battery Input: Connection terminals for the 48V DC battery bank.
  11. PV Input: Connection terminals for solar panel arrays.
  12. RS-232 Communication Port/WiFi-Port: For data communication and WiFi module connection.
  13. Circuit Breaker: Provides overcurrent protection.
DAXTROMN AGH-6.2KW-PRO Hybrid Solar Inverter Dimensions
Figure 2.2: Inverter Dimensions and Weight

Physical Dimensions:

  • Length: 423 mm (16.7 in)
  • Width: 334 mm (13.2 in)
  • Height: 110 mm (4.3 in)
  • Net Weight: 10.0 kg (22.0 lb)

3. Specifications

The DAXTROMN AGH-6.2KW-PRO Hybrid Solar Inverter offers robust performance for various solar power applications.

DAXTROMN AGH-6.2KW-PRO Inverter Charger Specifications Label
Figure 3.1: Inverter Charger Specifications Label
CategoryParameterValue
GeneralBrandDAXTROMN
ModelAGH-6.2KW-PRO
ColorWhite
Phase1-phase
Inverter OutputRated Output Power6200W / 6200VA
Nominal Output Voltage (Battery Mode)220/230/240V AC
Output WaveformPure Sine Wave
Surge Power (AC Input)12400W
Nominal Operating Frequency50/60Hz (Program Adjustable)
Full Load (Two Load Output)6200W
Maximum Main Load6200W
Maximum Second Load (Battery Mode)2067W
Main Load Cut-Off Voltage44V DC
Main Load Return Voltage52V DC
PV Input (DC)Maximum PV Input Power6500W
Nominal DC Voltage360V DC
Maximum DC Voltage (Vmax PV)500V DC
Start-up Voltage90V DC
Initial Feeding Voltage120V DC
MPPT Voltage Range90V DC - 450V DC
Full Load MPPT Range240V DC - 450V DC
Maximum Input Current23A
Grid Output (AC)Nominal Output Voltage220/230/240V AC
Output Voltage Range195.5 - 253V AC
Nominal Output Current27.0A
Power Factor>0.99
Feed-in Grid Frequency Range49 - 51 ± 1Hz
Maximum Conversion Efficiency (DC/AC)97%
AC InputAC Start-up Voltage120-140V AC
Auto Restart Voltage180V AC
Acceptable Input Voltage Range90-280V AC or 170-280V AC
Maximum AC Input Current40A
Battery & ChargerNominal DC Voltage48V DC
Maximum Solar Charging Current120A
Maximum AC Charging Current100A
EnvironmentalOperating Temperature-10 to 50 Celsius
CommunicationPortWiFi

4. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Always ensure all power sources are disconnected before making any connections.

4.1. Connection Diagram

The following diagram illustrates a typical connection setup for the DAXTROMN AGH-6.2KW-PRO inverter, integrating solar power, utility/generator, battery, and household appliances.

DAXTROMN AGH-6.2KW-PRO Hybrid Solar Inverter Connection Diagram
Figure 4.1: General Connection Diagram

4.2. PV Module Selection and Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules. Use appropriate cable sizes to reduce the risk of injury and ensure proper system safety and efficient operation.

PV Module Selection and Connection Guidelines
Figure 4.2: PV Module Selection and Connection Details

PV Connection Requirements:

  • Wire Size: 1 x 12 AWG (4 mm²)
  • Torque Value (Max): 1.2 Nm

PV Module Selection Parameters:

  • Max. PV Array Open Circuit Voltage (Voc): 500Vdc. The Voc of PV modules should not exceed this maximum.
  • PV Array MPPT Voltage Range: 90Vdc - 450Vdc. The open circuit voltage (Voc) of PV modules should be higher than the minimum battery voltage.

5. Operating Instructions

The inverter's LCD display and function buttons allow for easy monitoring and configuration of various operating parameters.

5.1. LCD Display and Function Buttons

Refer to Figure 2.1 in the Product Overview section for the location of the LCD display and function buttons. The LCD provides real-time status and data, while the buttons allow navigation through menus and adjustment of settings.

5.2. Program Settings

The inverter offers user-configurable programs to optimize performance based on your specific application and battery type.

5.2.1. Charging Voltage Settings

These settings are crucial for proper battery charging and longevity. Ensure they match your battery specifications.

Program Settings for Charging Voltages
Figure 5.1: Charging Voltage Program Settings
  • Program 26: Bulk charging voltage (C.V voltage)
    - 6.2KW/7.2KW default setting: 56.4V
    - Setting range: 48.0V to 58.0V (increment 0.1V) if 'self-defined' is selected in program 5.
  • Program 27: Floating charging voltage
    - 6.2KW/7.2KW default setting: 54.0V
    - Setting range: 48.0V to 58.0V (increment 0.1V) if 'self-defined' is selected in program 5.
  • Program 29: Low DC cut-off voltage
    - 6.2KW/7.2KW default setting: 40.0V
    - Setting range: 25.0V to 29.0V for 3.6KW model, and 40.0V for 6.2KW/7.2KW model (increment 0.1V) if 'self-defined' is selected in program 5.

5.2.2. Battery Equalization Settings

Battery equalization helps to balance the charge across battery cells, extending battery life. These settings are applicable if 'Flooded' or 'User-Defined' is selected in program 05.

Program Settings for Battery Equalization
Figure 5.2: Battery Equalization Program Settings
  • Program 30: Battery equalization
    - Enable (EEN) / Disable (EdS, default)
    - If enabled, the LCD main page will show "E9".
  • Program 31: Battery equalization voltage
    - 6.2KW/7.2KW default setting: 58.4V
    - Setting range: 48.0V to 61.0V (increment 0.1V).
  • Program 33: Battery equalized time
    - Default: 60 minutes
    - Setting range: 5 minutes to 900 minutes (increment 5 minutes).
  • Program 34: Battery equalized timeout
    - Default: 120 minutes
    - Setting range: 5 minutes to 900 minutes (increment 5 minutes).
  • Program 35: Equalization interval
    - Default: 30 days
    - Setting range: 0 to 90 days (increment 1 day).

5.2.3. Grid-Tie Operation Mode

Configure how the inverter interacts with the grid.

Program Settings for Grid-Tie Operation
Figure 5.3: Grid-Tie Operation Program Settings
  • Program 37: GRID-tie operation
    - Off grid (OFF, default): Inverter operates only in off-grid mode. Solar energy provides power to the loads as the first priority, followed by charging the battery.
  • Hybrid (HYd): Inverter operates in hybrid mode. Solar energy provides power to the loads as the first priority, then charges the battery, and any excess energy is fed back to the grid.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your DAXTROMN AGH-6.2KW-PRO inverter.

  • Visual Inspection: Periodically check the inverter for any visible damage, loose connections, or signs of overheating.
  • Cleanliness: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and cooling. Use a soft, dry cloth for cleaning the exterior. Do not use liquid cleaners.
  • Connection Checks: Annually, or as needed, verify that all electrical connections (PV, battery, AC input/output) are secure and free from corrosion.
  • Battery Health: Monitor battery voltage and performance regularly. Ensure battery equalization settings are appropriate for your battery type.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter has the latest features and bug fixes.

7. Troubleshooting

If you encounter issues with your inverter, refer to the fault indicator (component 4 in Figure 2.1) and the LCD display for error codes or messages. Here are some general troubleshooting steps:

  • No Power/Display Off:
    - Check the power on/off switch (component 6) to ensure it is in the 'ON' position.
    - Verify AC input power and battery connections.
    - Check the circuit breaker (component 13) for trips.
  • No AC Output:
    - Check if the inverter is in fault mode (fault indicator lit). Refer to the manual for specific fault codes.
    - Ensure battery voltage is within the operating range.
    - Verify AC output wiring and connected loads.
  • Battery Not Charging:
    - Check PV input connections and ensure solar panels are receiving sunlight.
    - Verify PV input voltage is within the MPPT range (90V DC - 450V DC).
    - Check AC input if AC charging is expected.
    - Review charging current settings in the program menu.
  • Overload Warning:
    - Reduce the total load connected to the inverter. The maximum main load is 6200W, and the maximum second load is 2067W.
  • Communication Issues (WiFi):
    - Ensure the WiFi module is correctly installed in the RS-232/WiFi port (component 12).
    - Check your network connection and router settings.

For persistent issues, consult the full product manual or contact customer support.

8. User Tips

  • Battery Compatibility: Always ensure your battery type and voltage settings (e.g., bulk charging, float charging, low DC cut-off, equalization) are correctly configured in the inverter's program menu to match your specific battery chemistry (e.g., lead-acid, lithium-ion). Incorrect settings can damage batteries.
  • Load Management: When operating in off-grid mode, be mindful of your total power consumption to avoid overloading the inverter. Prioritize essential loads and distribute them across the main and second outputs if necessary.
  • Environmental Protection: The inverter includes an anti-dusk kit for harsh environments. Ensure this is properly installed if your installation location is prone to dust or other particulates.
  • Monitoring: Utilize the built-in WiFi feature to monitor your system's performance remotely. This allows you to track energy production, consumption, and battery status, helping you optimize your solar setup.

9. Warranty and Support

For detailed warranty information and technical support, please refer to the official DAXTROMN website or contact your authorized dealer. Keep your purchase receipt and product serial number handy when seeking support.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.