VEVOR SPP150E, HCP750

Rate this product if you’ve used it
Contents

VEVOR Swimming Pool Pump Instruction Manual

Models: SPP150E, HCP750

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR Swimming Pool Pump. Designed for both in-ground and above-ground pools, hot tubs, thermal springs, and water amusement parks, this pump ensures crystal clear and sparkling water. Please read this manual thoroughly before installation and use, and keep it for future reference.

VEVOR Swimming Pool Pump main product view

Figure 1: VEVOR Swimming Pool Pump

2. Safety Instructions

WARNING: Failure to follow these instructions can result in serious injury or death.

  • Always disconnect power to the pump before performing any service or maintenance.
  • Installation must be performed by a qualified electrician and plumber in accordance with all local codes and ordinances.
  • Ensure the pump is properly grounded to prevent electrical shock.
  • Do not operate the pump if the power cord is damaged.
  • Keep children and pets away from the pump during operation.
  • Do not run the pump dry. Ensure the pump is primed with water before starting.
  • The pump is designed for water temperatures up to 122 ℉ (50 ℃). Do not exceed this temperature.
  • Protect the pump from freezing temperatures.

3. Product Overview

The VEVOR Swimming Pool Pump is engineered for durability and high performance, featuring a robust design and efficient operation.

Key Features:

  • Stable Performance: Made of thermoplastic ABS material for durability, providing high flow and head lift.
  • High Power Motor: Equipped with a 1 HP pure copper motor (IP55, 750W) for powerful, stable, and quiet running.
  • Removable Strainer Basket: Detachable filter basket with a see-through lid for easy cleaning and debris removal, extending pump lifespan.
  • Thermal Overload Protection: Built-in protection against overheating and damage, ensuring security and cooler running (up to 122 ℉/50 ℃).
  • Quiet Operation: Low noise design (<65dB) for a peaceful environment.
  • Wide Application: Suitable for various water systems including swimming pools, hot tubs, thermal springs, SPA, and irrigation systems.
Diagram showing pool pump cyclic operation with water inlet and outlet, max speed flow 4223 GPH, max head lift 52.5 FT

Figure 2: Pump Cyclic Operation and Flow

Internal view of the pump motor, highlighting the 1 HP copper motor

Figure 3: High Power Copper Motor

Close-up of the removable filter basket and transparent ABS lid

Figure 4: Removable Strainer Basket and Transparent Lid

4. Specifications

Refer to the table below for detailed technical specifications of the VEVOR Swimming Pool Pump models.

FeatureModel SPP150E (1 HP)Model HCP750 (1 HP)General
MaterialPlastic, MetalPlastic, Metal
StructureBooster PumpBooster Pump
Power1 HP / 750 W1 HP / 750 W
Voltage230V / 50Hz230V / 50HzAlso available in 110V (check product label)
Speed3450 RPM3450 RPM
Max. Head Lift52.5 ft / 16 m47.6 ft / 14.5 m
Max. Flow19200 L/h (4223 GPH)15000 L/h (3300 GPH)
Inlet/Outlet Diameter1.97 inch / 50 mm1.97 inch / 50 mm
Max. Temperature122 ℉ / 50 ℃122 ℉ / 50 ℃
Power Cable Length4.92 ft / 1.5 m4.92 ft / 1.5 m
Suitable ForAbove Ground Pools, In Ground Pools, All Water Types

Dimensions:

Dimensional drawing of SPP150E model: Length 20.79in, Height 12.0in, Width 7.09in, Inlet/Outlet 1.97in

Figure 5: Dimensions for Model SPP150E

Dimensional drawing of HCP750 model: Length 19.57in, Height 9.84in, Width 7.80in, Inlet/Outlet 1.97in

Figure 6: Dimensions for Model HCP750

5. Setup and Installation

5.1 Site Selection:

  • Choose a level, solid surface as close to the pool as possible to minimize friction loss from plumbing.
  • Ensure adequate ventilation around the pump motor.
  • Protect the pump from direct sunlight, excessive moisture, and freezing temperatures.

5.2 Plumbing Connections:

  • The pump features 1.97 inch (50 mm) inlet and outlet ports. Use appropriate plumbing fittings (2 x Fitting Hoses included) to connect to your pool's filtration system.
  • Ensure all connections are tight and leak-free. Use thread sealant tape on threaded connections.
  • Install shut-off valves on both the suction and discharge lines to allow for easy maintenance.

5.3 Electrical Connection:

  • Verify that the power supply voltage (110V or 230V, depending on your model) matches the pump's requirements as indicated on the product label.
  • The pump must be connected to a dedicated, properly grounded circuit protected by a Ground Fault Circuit Interrupter (GFCI).
  • The power cable length is 4.92 ft (1.5 m). Do not use extension cords.
  • Consult a qualified electrician for proper wiring to ensure compliance with local electrical codes.

6. Operating Instructions

6.1 Priming the Pump:

  • Before starting the pump for the first time, or after cleaning the strainer basket, the pump must be primed.
  • Turn off all power to the pump.
  • Remove the transparent lid of the strainer basket by turning the knob counter-clockwise.
  • Fill the strainer basket with water until it reaches the suction pipe level.
  • Replace the lid and ensure it is securely tightened to prevent air leaks.

6.2 Starting the Pump:

  • Ensure all valves are open and water can flow freely to and from the pump.
  • Restore power to the pump. The pump should start and begin circulating water.
  • Observe the pump for a few minutes to ensure it is operating smoothly and there are no leaks.
  • If the pump does not prime within 5 minutes, turn it off, re-prime, and restart.

6.3 Stopping the Pump:

  • Simply turn off the power supply to the pump.

7. Maintenance

7.1 Strainer Basket Cleaning:

  • Regularly inspect the transparent lid to check for debris in the strainer basket.
  • Turn off all power to the pump.
  • Remove the transparent lid and lift out the strainer basket.
  • Empty any collected debris and rinse the basket thoroughly.
  • Inspect the O-ring on the lid for cracks or wear; replace if necessary.
  • Return the basket, fill with water, and securely replace the lid.

7.2 Winterization:

  • In areas subject to freezing temperatures, the pump must be drained and stored indoors.
  • Turn off all power to the pump.
  • Drain all water from the pump by removing the drain plug (usually located at the bottom of the pump housing).
  • Disconnect plumbing and electrical connections.
  • Clean the pump thoroughly and store it in a dry, frost-free location.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your VEVOR Swimming Pool Pump.

ProblemPossible CauseSolution
Pump does not startNo power; tripped breaker/GFCI; motor overload; seized impellerCheck power supply; reset breaker/GFCI; allow motor to cool (thermal overload protection); inspect impeller for obstructions.
Low water flow or no flowClogged strainer basket; air leak in suction line; low water level in pool; clogged impellerClean strainer basket; check all suction line connections for leaks; ensure adequate pool water level; inspect and clean impeller.
Pump is noisyAir leak in suction line; cavitation (not enough water); debris in impeller; worn bearingsCheck suction line for leaks; ensure pump is properly primed; clean impeller; if noise persists, contact support.
Pump leaks waterLoose plumbing connections; damaged O-rings/seals; cracked housingTighten connections; inspect and replace O-rings/seals; if housing is cracked, pump may need replacement.
Pump overheats and shuts offMotor overload (thermal protection activated); insufficient ventilation; running dryAllow motor to cool; ensure adequate airflow around pump; ensure pump is primed and not running dry.

9. User Tips

  • Regular Inspection: Periodically check the transparent lid of the strainer basket to ensure it's clear of large debris, which can impede flow and strain the pump.
  • Optimal Placement: For best performance and reduced noise, place the pump on a stable, vibration-dampening surface.
  • Airflow: Ensure the motor has ample space for airflow to prevent overheating, especially during extended operation in warm weather.
  • Water Chemistry: Maintaining proper pool water chemistry can reduce strain on the pump and filter system, leading to longer equipment life.
Infographic comparing the low noise level of the pool pump (<65dB) to other common sounds

Figure 7: Quiet Operation

Collage showing various applications for the pump: hot spring, swimming pool, hydrotherapy pool, and water amusement park

Figure 8: Wide Application

10. Warranty and Support

VEVOR products are designed and manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official VEVOR website. Please have your model number (SPP150E or HCP750) and purchase date ready when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?