PowMr M25 M35 M45

Contents

PowMr MPPT Solar Charge Controller User Manual

Models: POW-M25-PRO, POW-M35-PRO, POW-M45-PRO

1. Product Introduction

Welcome to the POW-M series solar controllers, a forefront innovation in solar technology designed to provide exceptional performance and reliability for your solar system. Our meticulously designed controllers incorporate advanced digital control technology, featuring an LCD screen and user-friendly buttons to enhance configuration flexibility, allowing real-time monitoring of operational data and system status. Additionally, the controllers support Maximum Power Point Tracking (MPPT) battery charging mode, maximizing energy utilization efficiency.

PowMr MPPT Solar Controller with LCD Display, showing key features like 25A/35A/45A, 12V/24V, 100V Max PV, 3-Stages Charging.
Figure 1: PowMr MPPT Solar Charge Controller Overview

2. Package Contents

Upon opening the package, you will find the following items:

  • One (1) PowMr MPPT Solar Charge Controller
  • One (1) User Manual
  • One (1) Installation Guide Card
  • One (1) Set of Mounting Screws
Video 1: Unboxing and Initial Overview of the PowMr MPPT Solar Charge Controller. This video demonstrates the contents of the package and provides a brief introduction to the controller models and their current ratings (25A, 35A, 45A).

3. Product Features

  • Compatible with 12V/24V system voltages.
  • Available in 25A, 35A, and 45A charging current options to meet the needs of various solar energy storage systems.
  • The multi-stage charging algorithm is designed to optimize each charging cycle, maintaining battery charge through preset charging parameters for specific stages once the battery is fully charged.
  • MPPT technology tracks the maximum power point voltage (Vmp) of the array, which varies with weather conditions, ensuring maximum power is collected from the array throughout the day.
  • Innovative MPPT technology with tracking efficiency up to 99.9% and peak conversion efficiency up to 97%, reducing power consumption, heat generation, and operating temperature.

3.1 Adaptive Boost Charging

During initial charging, adaptive boost charging monitors the battery's response and automatically determines the appropriate boost stage duration for each independent charging cycle. This ensures the battery is fully charged at any discharge level or capacity, avoiding overcharging during the boost stage, thereby extending battery life.

3.2 Built-in Protections

The controllers are equipped with a built-in temperature sensor, lithium battery activation function, and multiple protection features to ensure safe and reliable operation of the system. These protections include:

  • PV over current
  • PV short circuit
  • PV reverse polarity
  • Battery reverse polarity
  • Battery over voltage
  • Battery over discharge
  • Lithium battery low temperature
  • Load overcurrent protection
  • Overtemperature
Diagram illustrating 9 certified built-in protections for the solar charge controller, including PV over current, PV short circuit, PV reverse polarity, battery reverse polarity, battery over voltage, battery over discharge, lithium battery low temperature, load overcurrent protection, and overtemperature.
Figure 2: Certified Built-in Protections
Graphic highlighting the safety, fast, and efficient operation of the PowMr 12V/24V Auto MPPT Solar Charge Controller, with 98% tracking efficiency and 97% peak conversion efficiency.
Figure 3: Safety, Fast, and Efficient Operation

4. Product Specifications

Detailed product specifications table for PowMr 25A, 35A, and 45A MPPT solar charge controller models, including solar input parameters (Max. PV Open-Circuit Voltage, Max. Input Power, Input Voltage Range), battery charging parameters (Charging Technology, Charging Algorithm, Nominal System Voltage, Battery Voltage Range, Rated Charging Current, Conversion Efficiency, Max. Power Point Tracking Efficiency, Temperature Compensation, Self-Consumption), DC output parameters (Rated DC Output Current), and general parameters (IP Class, Operating Temperature Range, Humidity Range, Altitude, Dimensions).
Figure 4: PowMr MPPT Solar Charge Controller Specifications

5. Installation Guide

The user-friendly design ensures easy and quick installation. Follow these steps for proper setup:

5.1 Physical Installation

  • Choose a suitable mounting location: The controller should be mounted vertically on a non-flammable surface, away from direct sunlight, high temperatures, and moisture. Ensure adequate airflow around the unit for cooling.
  • Mark mounting points: Use the controller as a template to mark the positions for the mounting screws.
  • Secure the controller: Fasten the controller to the wall or mounting surface using the provided screws.
Back view of the PowMr MPPT Solar Charge Controller, showing the heat sink and mounting holes for installation.
Figure 5: Rear View with Mounting Holes

5.2 Wiring Connections

Important: Ensure all power sources (solar panels, battery, load) are disconnected before making any connections. Connect in the following order:

  1. Connect the Battery: Remove the port cover. Connect the battery cables to the designated battery terminals on the controller (positive to positive, negative to negative).
  2. Connect the PV Array: Connect the solar panel cables to the designated PV array terminals on the controller (positive to positive, negative to negative).
  3. Connect the DC Load: Connect the DC load cables to the designated load terminals on the controller (positive to positive, negative to negative).
  4. Reassemble the Port Cover: Once all connections are secure, replace the port cover.

Connection Order: Battery → PV Array → DC Load. Disconnect in reverse order.

Wiring diagram for the solar charge controller, showing connections for battery, load, and PV array. The diagram indicates the correct order of connection: 1) Battery, 2) Load, 3) PV array, and disconnection in reverse order.
Figure 6: Schematic Wiring Diagram
Side view of the PowMr MPPT Solar Charge Controller, showing the connection ports for battery, PV, and load.
Figure 7: Side View with Connection Ports
Top-down view of the PowMr MPPT Solar Charge Controller, showing the clearly labeled connection terminals.
Figure 8: Top View of Connection Terminals

6. Operating Instructions

6.1 Initial Startup

After completing all wiring connections, activate the controller by connecting the battery first, then the PV array. The LCD screen will illuminate, indicating the controller is operational.

6.2 LCD Display and Buttons

The controller features an LCD screen and user-friendly buttons for configuration and monitoring.

Front view of the PowMr MPPT Solar Charge Controller, showing the LCD screen and four control buttons labeled PV, BAT/up arrow, DC/down arrow, and SET/gear icon.
Figure 9: Front Panel with LCD and Control Buttons

Working Modes:

  • 3.0: Night mode, no charging
  • 4.0: MPPT Charging Mode
  • 7.0: Boost Charging Mode
  • 8.0: Floating Charge mode
Detailed view of the Backlight LCD Screen, illustrating working modes (Night mode, MPPT Charging, Boost Charging, Floating Charge) and a table of Fault Codes with causes and solutions.
Figure 10: LCD Screen Details and Working Modes

6.3 Battery Type Configuration

The controller is compatible with various lithium and lead-acid batteries. To set the battery type:

  1. Long press the BAT/▲ key to enter the setting program.
  2. Use the BAT/▲ and DC/▼ keys to toggle through the battery type options.
  3. Press the SET/⚙ key to save and confirm your selection.
  4. If you select a User-defined battery type, you can proceed with setting the following battery parameters as needed.
Diagram showing compatibility with multiple 12V/24V battery types including AGM, GEL, FLD, LI, and SLA. It also indicates that user-defined battery types can be configured.
Figure 11: Compatible Battery Types

7. Maintenance

To ensure optimal performance and longevity of your PowMr MPPT Solar Charge Controller, regular maintenance is recommended:

  • Cleanliness: Keep the controller clean and free from dust and debris. Use a dry, soft cloth for cleaning.
  • Connections: Periodically check all wiring connections to ensure they are tight and secure. Loose connections can cause overheating and damage.
  • Ventilation: Ensure that the ventilation fins on the back of the controller are not obstructed to allow for proper heat dissipation.
  • Environment: Verify that the operating environment remains within the specified temperature and humidity ranges (-35℃ to +45℃, ≤95% Non-condensing).

8. Troubleshooting

The controller's LCD screen displays fault codes to help diagnose issues. Refer to the table below for common fault codes and their solutions:

Table of Fault Codes, Fault Causes, and Solutions. Examples include Fault Code 18 (Input photovoltaic voltage too low), 60 (Overtemperature protection), 63 (Battery voltage too high), 65 (Battery voltage too low), 71 (Input photovoltaic voltage too high), 73 (Overcharging current), and 72 (Overdischarging current).
Figure 12: Fault Codes and Solutions

For detailed information on specific fault codes and advanced troubleshooting, please consult the full user manual provided with your product.

9. User Tips

No specific user tips from reviews or Q&A were provided for this product. Always ensure proper ventilation and follow the wiring instructions carefully for optimal performance and safety.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided in your product packaging or visit the official PowMr website. Keep your purchase receipt as proof of purchase for warranty claims.

Ask a question about this manual