COMPTYCO AUA-C607/C605

Contents

COMPTYCO AUA-C607/C605 Rechargeable Active Optical Fiber Identifier User Manual

Model: AUA-C607 / AUA-C605

1. Introduction

The COMPTYCO AUA-C607/C605 is a multifunctional optical fiber identifier designed for efficient and non-destructive testing of live optical fibers. It integrates an Optical Power Meter (OPM), Optical Fiber Identifier (OFI), Visual Fault Locator (VFL), and LED illumination, making it a versatile tool for FTTH (Fiber to the Home) applications and general fiber optic network maintenance. This device is rechargeable and features a micro-bending test method that ensures no damage to the active fiber during identification.

COMPTYCO AUA-C607/C605 Rechargeable Mini Fiber Identifier showing OPM, OFI, VFL, and LED functions.
Figure 1: Overview of the Multifunctional Optical Fiber Identifier (AUA-C607 model shown).

2. Key Features

  • Four-in-One Functionality: Combines Optical Power Meter (OPM), Optical Fiber Identifier (OFI), Visual Fault Locator (VFL), and LED flashlight.
  • Non-Destructive Testing: Utilizes micro-bending technology to identify live fibers without interrupting traffic.
  • Universal Fixture: Compatible with various fiber diameters including 0.25mm, 0.9mm, 2.0mm, and 3.0mm.
  • High-Precision OPM: Measures optical power with a 2.5mm universal interface, supporting SC/FC/ST/LC connectors (optional adapters may be required for LC).
  • Concealed VFL & LED: Integrated VFL for fault location and LED for illumination in dark environments.
  • Rechargeable Battery: Built-in 3.7V 650mAh lithium battery, conveniently charged via a Type-C USB port.
  • Signal Frequency Identification: Capable of identifying 270Hz, 1kHz, and 2kHz signal frequencies.
  • Automatic Shutdown: Power-saving feature with automatic shutdown after 10 minutes of inactivity.

3. Package Contents

Please check the package carefully upon receipt to ensure all items are present and undamaged.

  • COMPTYCO AUA-C607/C605 Optical Fiber Identifier Unit
  • USB Type-C Charging Cable
  • Wrist Strap
  • Carrying Case
  • User Manual (this document)
Image showing the COMPTYCO AUA-C607/C605 device, USB-C cable, wrist strap, and carrying case.
Figure 2: Included accessories in the product package.

4. Setup and Charging

4.1 Initial Charging

Before first use, fully charge the device. Connect the provided USB Type-C cable to the charging port on the device and plug the other end into a standard USB power adapter (not included) or a computer USB port.

Close-up of the Type-C charging port on the COMPTYCO AUA-C607/C605 device.
Figure 3: Type-C charging port location.

4.2 Power On/Off

Press and hold the power button (usually marked with a power symbol) to turn the device ON or OFF. The display will illuminate when powered on.

5. Operating Instructions

5.1 Optical Fiber Identification (OFI)

The OFI function allows for non-destructive identification of live optical fibers. This method uses micro-bending to detect the presence and direction of light without damaging the fiber.

  1. Open the universal fixture by sliding the mechanism.
  2. Carefully place the fiber into the fixture. Ensure the fiber is seated correctly for accurate measurement. The device supports 0.25mm, 0.9mm, 2.0mm, and 3.0mm fiber diameters.
  3. Close the fixture gently.
  4. The device will automatically detect the signal and display the optical power and signal direction on the screen.
  5. The screen icons will indicate left or right for signal direction.
  6. The device can identify signal frequencies of 270Hz, 1kHz, and 2kHz.
COMPTYCO AUA-C607/C605 performing a micro-bending test on a fiber, showing compatibility with different fiber sizes.
Figure 4: Micro-bending test for fiber identification, compatible with various fiber types.

5.2 Optical Power Meter (OPM)

To measure optical power, use the dedicated OPM port.

  1. Open the protective cover for the OPM port.
  2. Insert the fiber connector (SC/FC/ST/LC, 2.5mm universal interface) into the OPM port.
  3. The device will display the measured optical power in dBm.
  4. Press the 'dB' button to switch between different measurement units or modes if available.
  5. The OPM measures across a wavelength range of 850nm to 1650nm.
Hand holding the COMPTYCO AUA-C607/C605, demonstrating the use of the high-precision optical power meter with a fiber connector.
Figure 5: Using the Optical Power Meter function.

5.3 Visual Fault Locator (VFL)

The VFL function emits a visible red laser light to locate breaks, bends, or poor connections in optical fibers.

  1. Open the protective cover for the VFL port.
  2. Connect the fiber to be tested to the VFL port.
  3. Press the 'VFL' button to activate the red laser.
  4. Observe the fiber for any visible light leakage, which indicates a fault.
  5. The VFL output optical power is ≥10-30mW with a wavelength of 650nm.
Close-up of the COMPTYCO AUA-C607/C605 showing the concealed VFL and LED ports, with the VFL emitting red light.
Figure 6: Activating the Visual Fault Locator (VFL).

5.4 LED Illumination

The integrated LED provides illumination for working in dimly lit environments.

  1. Press the 'LED' button to turn the LED light ON or OFF.

5.5 Saving Measurements (SAVE button)

The device may have a function to save measurements. Refer to the on-screen prompts or specific model instructions for details on how to save and recall data using the 'SAVE' button.

5.6 Reference Power Setting (REF button)

The 'REF' button is typically used to set a reference power level for relative measurements (e.g., insertion loss). Consult the device's display and specific model instructions for setting and using reference values.

6. Specifications

The following table details the technical parameters for the COMPTYCO AUA-C607/C605 Optical Fiber Identifier.

Table of Technical Parameters for COMPTYCO AUA-C607/C605, including wavelength range, signal recognition, detector type, fiber types, OPM range, VFL output, dimensions, and power supply.
Figure 7: Technical Parameters.
FeatureParameter
Wavelength Range (OFI)800-1700nm
Signal Recognition TypeCW, 270Hz ± 5%, 1kHz ± 5%, 2kHz ± 5%
Detector TypeΦ 1mm InGaAs 2 pcs
Adapted Fiber TypeΦ 0.25/Φ 0.9 (bare fibers); Φ 2.0, Φ 3.0 (tail fiber)
Signal DirectionScreen icon displays left and right directional indicators
Signal Frequency Range270Hz, 1kHz, 2kHz
Measuring Range of Optical Power Meter-70 ~ +10dBm / -50 ~ +26dBm
Probe Type (OPM)InGaAs
Wavelength Range (OPM)850 ~ 1650nm
Standard Wavelength (nm)850, 980, 1270, 1300, 1310, 1490, 1550, 1577, 1625, 1650
Display ResolutionLinear: 0.1%, Logarithmic: 0.01dBm
Working Temperature-10 ~ +60°C
Storage Temperature-25 ~ +70°C
Automatic Shutdown Time10 minutes
Output Optical Power of Red Light Source (VFL)≥10-30mW
Red Light Source Output Wavelength (VFL)650nm
Overall Dimensions (mm)240 × 47 × 30
Power SupplyRechargeable lithium battery (3.7V 650mAh)
Weight (Single Machine)Approx. 100g

7. Maintenance and Care

  • Cleaning: Use a soft, dry cloth to clean the exterior of the device. For optical ports, use specialized fiber optic cleaning tools and solutions to avoid contamination.
  • Storage: Store the device in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the protective caps are on all optical ports when not in use.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Recharge the device regularly, especially if it will be stored for an extended period.
  • Avoid Impact: Protect the device from drops and impacts, as this can damage the internal optical components.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low or depleted battery.Charge the device using the Type-C cable.
Inaccurate OPM readings.Contaminated OPM port or fiber connector. Incorrect wavelength setting (if applicable).Clean the OPM port and fiber connector. Ensure the correct wavelength is selected for measurement.
OFI not detecting signal.Fiber not properly seated in the fixture. Fiber is dead (no signal).Re-seat the fiber correctly in the universal fixture. Verify the fiber is active using other means if possible.
VFL red light is dim or not visible.Low battery. VFL port or fiber end-face is dirty.Charge the device. Clean the VFL port and fiber end-face.

9. User Tips

  • Always ensure fiber ends are clean before connecting to any optical port to prevent damage and ensure accurate readings.
  • When using the OFI, apply gentle pressure to the fiber in the fixture. Excessive force is not necessary and could potentially damage the fiber.
  • Utilize the LED light in dark work environments to improve visibility and safety.
  • Keep the device in its protective carrying case when not in use to prevent physical damage and dust accumulation.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.

© 2023 COMPTYCO. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.