1. Product Overview
The JIKONG Inverter BMS (Battery Management System) is a sophisticated management system designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge/over-current/over-temperature protection, a coulomb meter, Bluetooth communication, and host computer monitoring functions. This BMS is suitable for LiFePO4, Li-ion, and LTO battery types, making it ideal for home energy storage, base station backup power, and solar power station applications.
The system utilizes energy transfer active balancing technology to achieve a maximum continuous balance current of 1A or 2A, significantly improving battery consistency, extending battery life, and delaying aging. It supports mobile APP control for Android, iOS, and HarmonyOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches.
2. Safety Precautions
! Please read this instruction manual carefully before use.
- Wiring: Connect cables from the negative terminal to the positive terminal according to the wiring diagram for the corresponding number of strings. After connecting the balanced wire, use a multimeter to confirm correct connections before inserting the protection board.
- Passwords: The default password for the protection board is
1234, and the default authorization password is123456. After connecting the mobile APP to the protection board, change the connection password immediately to prevent unauthorized access. - Modifications: Do not modify the power line of the protection board without permission. Unauthorized modifications can cause uneven overcurrent and burn the protection board.
3. Setup and Installation
3.1. Package Contents
The package includes the following components:
- 1 * BMS unit
- 1 * Interface board
- Adapter cables (various lengths: 40cm, 90cm)
- 1 * RS485 cable (40cm)
- Sampling lines (various lengths: 90cm)
- 1 * Switch (50cm)
- 1 * Heating Adapter cable (15cm)
- 1 * 4.3 inches touch screen
3.2. Wiring Instructions
The JIKONG-PB1/2A16S-10/15/20P series protection board is designed for 7-16 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always refer to the provided wiring diagrams for correct installation.
- Connect all cables securely.
- Insert the cables into the BMS.
- Connect the B-line and the P-line to the battery.
- If there are two B8 cables, only the first B8 line needs to be connected. The second B8 cable is not required.
3.3. Device Activation
Before powering on the protection board, double-check that all balance cables are properly connected and that the P- and B- terminals are correctly wired. Ensure the protection board is securely fixed to the battery cells. Incorrect connections can lead to abnormal operation or even damage to the board.
The protection board is designed for charging activation. After the battery assembly is complete, connect a charger (with voltage 2V higher than the battery voltage) to activate the BMS. Alternatively, if you have the optional display screen and button, simply insert the cable into the display interface and press the button to activate the device.
4. Operating Instructions
4.1. Mobile APP and Display Interface
The JIKONG BMS supports a mobile application for Android, iOS, and HarmonyOS. You can download the APP by scanning the QR code provided in the manual (Android Version 7 minimum is required). The APP allows you to check battery status, modify working parameters, and control charge/discharge switches via Bluetooth.
The BMS also features a reserved display interface, allowing users to connect a JIKONG display for convenient viewing of battery information. The display can show voltage, current, temperature, and state of charge (SOC).
4.2. Active Balancing
The active balancing feature transfers energy from higher-voltage cells to lower-voltage cells to maintain battery consistency. Users can set the balance trigger pressure difference (mV) in the APP. Balancing automatically activates when the voltage difference between any two strings exceeds the set value and deactivates when it falls below the set value. The default balance current is 1A or 2A, adjustable based on battery capacity (recommended not to exceed 0.2C).
4.3. Heating Function
The BMS includes a standard heating function to warm the battery in low-temperature conditions, preventing reduced activity and ensuring optimal charging/discharging. The designed heating current is 10A. Users can select and configure heating devices (resistance heaters or heating films) as needed. It is recommended to use a normally closed temperature switch (45°C to 65°C) in series with the heating circuit for secondary protection.
4.4. Communication and Parallel Function
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate inverter protocol via the APP. There are two RS485 communication interfaces: RS485-1 for inverter communication and RS485-2 for parallel battery pack connection and communication with a host computer. The default baud rate is 115200. The BMS address can be set using DIP switches for parallel configurations (0-15 addresses, with address 0 as the host).
5. Maintenance
Regularly inspect all connections for tightness and ensure the BMS and battery cells are clean and free from debris. The intelligent sleep function can be enabled via the APP to reduce energy consumption when the BMS is in standby (charging/discharging current less than 1A for 26 consecutive hours). To reactivate, press the button or connect a charger.
For optimal battery health, it is recommended to adjust the active balance current in the APP so that it does not exceed 0.2C of the battery capacity (C).
6. Troubleshooting
6.1. Protection Functions and Recovery
The BMS is equipped with various protection mechanisms. When a protection is triggered, the BMS will shut down the relevant function (charging or discharging) and automatically recover once the conditions return to normal. Users can adjust delay and recovery times for most protections via the APP.
- Overcharge Protection: Shuts down charging if any cell voltage exceeds the set overcharge voltage. Recovers when all cell voltages drop below the recovery voltage.
- Over-discharge Protection: Shuts down discharging if any cell voltage drops below the set undervoltage protection. Recovers when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell voltage falls below the automatic shutdown voltage.
- Charge Overcurrent Protection: Shuts down charging if the current exceeds the set continuous charging current for a specified delay. Recovers after a set release time.
- Discharge Overcurrent Protection: Shuts down discharging if the current exceeds the set continuous discharge current for a specified delay. Recovers after a set release time.
- Overtemperature Protection: Shuts down charging/discharging if the temperature exceeds the set overtemperature value. Recovers when the temperature drops below the recovery value.
- Low Temperature Protection: Shuts down charging if the temperature drops below the set low temperature value. Recovers when the temperature rises above the recovery value.
- Short Circuit Protection: Automatically triggers if a short circuit is detected. Users can adjust the delay and recovery time via the APP. If a short circuit occurs during initial charging or discharging due to high peak currents from the charger or load, increasing the delay time may resolve the issue.
6.2. Emergency Switch
The emergency switch function allows the BMS to continue charging and discharging for 30 minutes in case of issues like over-temperature, over-discharge, over-charge, or dropped strings during normal operation. This provides a critical window for emergency use, even if a single cell reaches the automatic shutdown voltage. The protection board will continue to operate until the 30-minute cycle ends to prevent dangerous situations.
6.3. LED Indicators
The interface board features LED indicators to help users monitor the BMS status and remaining battery power. Refer to the tables below for detailed descriptions of LED behavior:
| Status | ON/OFF Indicator | RUN | ALM | L1-L6 | Instructions |
|---|---|---|---|---|---|
| Power Off (Normal) | OFF | ||||
| Balance (Normal) | ON | Flicker | OFF | Battery based display | |
| Charging (Normal) | ON | Flicker | OFF | Battery based display | |
| Charging (Overcurrent, Overtemp, Overvoltage, Failure) | ON | Flicker | Flicker | Battery based display | |
| Discharging (Normal) | ON | Flicker | OFF | Battery based display | |
| Discharging (Overcurrent, Overtemp, Undervoltage, Failure) | ON | Flicker | Flicker | Battery based display | |
| Other Alarms (Password not changed, Short circuit, Temperature) | ON | Flicker | Flicker | Battery based display |
Note: When the device address is set to 0 (host), the last LED indicator L6 blinks. For other addresses (slave), the slave is off and blinks after successful communication with the host.
| Capacity (%) | Charging (L5-L1) | Discharging (L5-L1) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0-20% | OFF | OFF | OFF | OFF | ON | OFF | OFF | OFF | OFF | ON |
| 20-40% | OFF | OFF | OFF | ON | ON | OFF | OFF | OFF | ON | ON |
| 40-60% | OFF | OFF | ON | ON | ON | OFF | OFF | ON | ON | ON |
| 60-80% | OFF | ON | ON | ON | ON | OFF | ON | ON | ON | ON |
| 80-100% | ON | ON | ON | ON | ON | ON | ON | ON | ON | ON |
Note: ON indicates that the LED is on, OFF indicates that the LED is off.
7. Specifications
The JIKONG Inverter BMS is available in several models, each with specific current ratings and balancing capabilities. Below are the general and default parameters:
7.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30-70 | °C |
| Max. Number of Collection Strings | 16 | S |
| Max. Balancing Current | 1 / 2 | A |
| Max. Charging Current (10P/15P/20P) | 100 / 150 / 200 | A |
| Max. Discharge Current (10P/15P/20P) | 100 / 150 / 200 | A |
| Max. Instantaneous Current (10P/15P/20P) | 200 / 300 / 400 | A |
| Max. Internal Loop Resistance (10P/15P/20P) | 1 / 0.45 / 0.35 | mΩ |
| Protective Plate Size | 300x100x24 | mm |
| Finished Weight | 1000 | g |
7.2. Default Parameters
| Parameter | Li-ion (Ternary) | LiFePO4 | LTO (Titanate) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Max. Balancing Current | 1 / 2 | 1 / 2 | 1 / 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.17 | 3.54 | 2.64 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 3 | 3 | 3 | S |
| Charging Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | uS |
| Short Circuit Protection Release Time | 30 | 30 | 30 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charging Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charging Low Temperature to Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Protection Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
8. User Tips
- Mounting: Plan your battery mounting carefully to ensure proper fit and ventilation for the BMS.
- Security: Always change the default Bluetooth and parameter setting passwords (
1234and123456respectively) immediately after initial setup to prevent unauthorized access. - Balancing: For optimal battery longevity and performance, ensure the active balance current is set to not exceed 0.2C of your battery's capacity.
- Wiring Verification: Double-check all wiring with a multimeter before connecting the BMS to prevent damage.
9. Warranty and Support
For any inquiries, technical support, or warranty claims, please contact JIKONG customer service. Refer to the full PDF manual for detailed information on troubleshooting and advanced configurations. The latest version of the manual is 19.0.1, published by Chengdu Jikong Technology Co. LTD.
PDF Manual Reference: JIKONG Lithium Battery Active Balance Protection Board Maintenance Manual (PDF)