1. Introduction
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the LCTC LCSSR-1 series Single Phase Solid State Relays (SSRs). These relays are designed for various control applications, including DC to AC, DC to DC, and AC to AC switching, with current ratings ranging from 10A to 240A. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

2. Safety Information
WARNING: Electrical shock hazard. Always disconnect power before installation or servicing.
- Ensure all wiring is performed by a qualified electrician and complies with local and national electrical codes.
- Verify that the control voltage and load voltage match the specifications of the selected relay model.
- For inductive loads, a suppression circuit must be added to prevent damage to the relay.
- Always apply thermal conductive silicone grease between the SSR and any heat sink to ensure proper heat dissipation.
- Tighten all terminal screws properly to prevent loose connections and overheating.
- Do not use the relay beyond the parameters specified in the datasheet. Exceeding current or voltage ratings can lead to product failure and safety hazards.
- In the off-state, scenarios where the off-state leakage current is less than 5mA are not applicable for some models. Please purchase with caution and consult specifications.
- This product is not suitable for controlling asynchronous motors.
3. Product Features
- MOSFET Output: Provides efficient and reliable switching.
- LED Indicator: Visual indication of relay status.
- Low On-State Resistance: Minimizes power loss and heat generation during operation.
- Photo Isolation: Ensures electrical isolation between the control circuit and the load circuit for enhanced safety.
- Protective and Sealed Design: Offers durability and protection in various environments.
- CE Certified: Meets European safety standards.
4. Specifications
The LCTC LCSSR-1 series includes various models tailored for different applications. Below is a consolidated table of general specifications. Please refer to the specific model's datasheet for precise values.
General Specifications (LCSSR-1 Series)
| Parameter | LCSSR-1DA (DC-AC) | LCSSR-1AA (AC-AC) | LCSSR-1DD (DC-DC) |
|---|---|---|---|
| Load Current Range | 10A - 240A | 10A - 240A | 10A - 240A |
| Output Voltage | 24-480VAC | 24-480VAC | 5-220VDC |
| Control Voltage | 3-32VDC | 70-280VAC | 3-32VDC |
| Max Input Current | <15mA | <20mA | <35mA |
| Must Operate Voltage | 2.8VDC | 70VAC | 3VDC |
| Must Release Voltage | 1.5VDC | 30VAC | 1.5VDC |
| Peak Voltage | 800V | 800V | 250VDC |
| On-state Voltage Drop | ≤1.5V | ≤1.5V | 0.5V |
| Off-state Leakage Current | 2mA | 2mA | 0.01mA |
| Dielectric Strength | 2500V | 2500V | 2500V |
| Operating Temperature | -30°C to 80°C | -30°C to 80°C | -30°C to 80°C |
| Dimensions (L×W×H) | 58.5mm × 45.5mm × 29mm | ||
| Weight | 95g - 100g (approx.) | ||
| Certification | CE | ||
| Power Source | DC (for control) | ||
| EU LVD Voltage | Below 50Vac or 75Vdc | ||


5. Installation
Proper installation is crucial for the safe and reliable operation of your Solid State Relay.
5.1. Mounting
The SSR can be mounted using screws or on a DIN rail, depending on the specific model and your application needs. Ensure a stable and secure mounting surface.

5.2. Heat Dissipation
For currents exceeding 10A, a heat sink is mandatory to prevent overheating and ensure the longevity of the relay. Thermal conductive silicone grease must be applied evenly between the solid state relay and the heat sink for optimal heat transfer.

6. Wiring Diagrams
Always ensure power is disconnected before performing any wiring. Refer to the specific model type (DA, AA, DD) for correct connections.
6.1. DC-AC (DA Type) Wiring
For DC control to AC load applications. The control voltage is typically 3-32VDC, and the load voltage is 24-480VAC.

6.2. AC-AC (AA Type) Wiring
For AC control to AC load applications. The control voltage is typically 70-280VAC, and the load voltage is 24-480VAC.

6.3. DC-DC (DD Type) Wiring
For DC control to DC load applications. The control voltage is typically 3-32VDC, and the load voltage is 5-220VDC.
(No specific DD wiring diagram image provided, general wiring principles apply: connect DC control to input terminals, and DC load to output terminals, observing polarity.)
7. Operation
Once properly installed and wired, the Solid State Relay operates by switching the load circuit based on the presence or absence of the control signal. The integrated LED indicator provides visual feedback on the relay's status (ON/OFF).
- Control Signal: Apply the specified control voltage to the input terminals (3 and 4).
- Load Switching: When the control voltage is applied, the relay switches the load circuit (terminals 1 and 2) ON. When the control voltage is removed, the relay switches the load circuit OFF.
- LED Indicator: The LED will illuminate when the control signal is active and the relay is in the ON state.
Always ensure that the load current does not exceed the relay's rated capacity. For optimal performance and longevity, it is recommended to operate the relay below its maximum rated current.
8. Maintenance
Solid State Relays are generally low-maintenance devices. However, periodic checks can help ensure continued reliable operation:
- Terminal Tightness: Periodically check and re-tighten all terminal screws to ensure secure electrical connections. Loose connections can lead to overheating and poor performance.
- Heat Sink Inspection: Ensure the heat sink (if used) is free from dust and debris, which can impede airflow and reduce cooling efficiency. Clean as necessary.
- Thermal Grease: Over time, thermal grease can degrade. If the relay is operating in a high-temperature environment or if you observe signs of overheating, consider reapplying thermal conductive silicone grease between the SSR and the heat sink.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature range (-30°C to 80°C) and is free from excessive moisture or corrosive agents.
9. Troubleshooting
If your Solid State Relay is not functioning as expected, consider the following common issues and solutions:
- Relay Not Switching:
- Verify that the control voltage is within the specified range for your model (e.g., 3-32VDC for DA/DD, 70-280VAC for AA).
- Check the polarity of the DC control voltage for DA and DD models.
- Ensure the load voltage is present and within the relay's output voltage range.
- Inspect wiring for loose connections or breaks.
- Overheating:
- Ensure a properly sized heat sink is installed, especially for currents above 10A.
- Verify that thermal conductive silicone grease has been applied correctly between the SSR and the heat sink.
- Check if the load current exceeds the relay's rated capacity. Reduce the load if necessary.
- Ensure adequate ventilation around the relay and heat sink.
- Unexpected Behavior with Inductive Loads:
- Confirm that a suppression circuit (e.g., snubber circuit) is installed for inductive loads to protect the relay from voltage spikes.
- Leakage Current in Off-State:
- Some SSR models may exhibit a small off-state leakage current. If this is critical for your application, ensure the chosen model's specifications meet your requirements. Note that for some models, an off-state leakage current less than 5mA is not guaranteed.
- Incompatibility with Asynchronous Motors:
- This relay series is not designed for controlling asynchronous motors. Using it for such applications may result in malfunction or damage.
If the problem persists after checking these points, please contact LCTC technical support.
10. User Tips
- Application Versatility: Users have successfully employed these relays with temperature controllers in refrigerators and for general heating applications.
- Enclosure for Protection: For outdoor or harsh environments, consider installing the SSR in a sealed enclosure to protect it from moisture and dust.
- DC-DC Relay Functionality: A DC-DC solid-state relay typically allows current to flow in one direction only (unidirectional switching). It does not pass current in both directions like a mechanical switch.
- AC-AC Zero-Crossing: AC-AC SSRs often utilize zero-crossing switching, which helps reduce electrical noise and extends the life of the load and the relay.
11. Warranty & Support
For comprehensive product selection details, technical assistance, or in case of any errors in the product information, please contact our sales department.
WENZHOU LEICHI TECHNOLOGY CO., LTD.
- Telephone: +8613336973699
- Email: 364434415@qq.com
- Website: www.aliexpress.com/store/5395027
- Address: JINQIAO WEST ROAD, YUEQING CITY, WENZHOU, ZHEJIANG PROVINCE, CHINA
A detailed user manual in PDF format is also available for download: User Manual (PDF)