TOMZN TOB7Z-63

Contents

TOMZN TOB7Z-63 DC MTS Dual Power Manual Transfer Switch Circuit Breaker User Manual

Model: TOB7Z-63

1. Safety Information

Warning: To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or playpens. This bag is not a toy.

This device operates at high voltages. Installation and operation should only be performed by a qualified electrical professional to ensure safety and proper functionality.

General Precautions:

  • Do not place the device near flammable materials.
  • Ensure adequate ventilation during operation to prevent overheating.
  • Disconnect from power and store properly when not in use for extended periods.
Recycling symbols for electronic devices and packaging

Recycling information: This image shows symbols indicating that the device, its accessories, cords, and batteries should be recycled. Packaging elements should be separated for sorting.

2. Product Overview

The TOMZN TOB7Z-63 DC MTS (Manual Transfer Switch) is a dual power circuit breaker designed for PV (Photovoltaic) systems. It allows for manual switching between two DC power sources, providing overload and short circuit protection.

Key Features:

  • Overload Protection: Safeguards the circuit from excessive current.
  • Short Circuit Protection: Automatically cuts off the circuit in case of a short circuit.
  • Visualization Window: Red and green indicators provide clear status of line connection.
  • Interlocking Chain Accessories: Enables free conversion between two power sources without simultaneous connection.
  • Widen D-handle: Ergonomically designed for comfortable operation.
  • U-shaped Wiring Port: Simplifies wiring and connection.
  • Buckle Design: Facilitates secure installation.
  • Flame-retardant Shell: Enhances safety.
  • CE Certified: Complies with European safety standards.
Graphic showing key features: Overload protection, Wide handle, View window, Buckle design, CE certification, Flame-retardant shell.

This image highlights the main features of the circuit breaker, including various protection mechanisms and design elements.

3. Specifications

Attribute Value
Product Name DC MTS Dual Power Manual Transfer Switch Circuit Breaker
Brand TOMZN
Model Number TOB7Z-63
Pole Number 2P+2P
Rated Max Voltage DC 1000V
Rated Current Options 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Breaking Capacity 10Ka
Product Features Overload/Short Circuit Protection
Product Wiring 35mm Din rail
EU LVD Voltage High voltage: Above 50Vac or 75Vdc
Is Smart Device No
Wireless Functionality No
Includes Battery No
Dimensions (Approx.) Width: 79mm, Height: 81mm, Depth: 75mm
Package Weight 0.408 kg
Diagram showing the dimensions of the circuit breaker: 79mm width, 81mm height, 75mm depth.

This image illustrates the physical dimensions of the TOB7Z-63 circuit breaker.

4. Setup and Installation

Important: Installation must be carried out by a qualified electrical professional.

  1. Initial Inspection: After receiving the product, visually inspect it for any damage.
  2. Mounting: Install the circuit breaker onto a standard 35mm DIN rail. Ensure the buckle design is securely fastened.
  3. Wiring: Connect the equipment in accordance with the provided wiring diagram specifications. Use the U-shaped wiring ports for simple and convenient connections.
  4. Parameter Adjustment: According to the specific requirements of your PV system, adjust any necessary equipment parameters.

Installation Diagrams:

Image showing the circuit breaker mounted on a DIN rail.

This image demonstrates how the circuit breaker is mounted on a DIN rail.

Installation schematic showing how to install the buckle on the circuit breaker.

This schematic illustrates the buckle mechanism for secure installation.

Wiring diagram for DC MTS interlock circuit breaker, showing connections for Common Electricity A, Standby B, and Load.

This diagram provides instructions for wiring the DC MTS interlock circuit breaker, connecting common electricity, standby power, and the load.

Installation display diagram showing the circuit breaker installed in a distribution box.

This image shows an example of the circuit breaker installed within a distribution box.

5. Operating Instructions

The TOB7Z-63 is a manual transfer switch designed for safe and reliable switching between two DC power sources.

Switching Operation:

  1. Switch Up (Line Connected): When the handle is in the 'up' position, the corresponding line is connected. The green indicator will be visible.
  2. Switch Down (Line Disconnected): When the handle is in the 'down' position, the corresponding line is disconnected. The red indicator will be visible.

Working Principle: The interlock mechanism ensures that only one power source can be connected at a time. To switch between sources, the currently active power supply must be turned off first, and then the new power supply can be switched on. This prevents short circuit problems during transfer.

Diagram explaining 'Switch up' for line connection status and 'Switch down' for line disconnected and closed state, detailing the interlocking principle.

This diagram illustrates the switch positions and their corresponding line statuses, emphasizing the safe switching procedure.

Visualization window with red and green indicators on the circuit breaker, showing interlocking chain accessories for free conversion.

This image shows the red and green indicators that provide visual feedback on the connection status of each line.

Play video
Watch video online

Video demonstrating the manual switching operation of the circuit breaker.

6. Maintenance

To ensure the longevity and reliable operation of your TOMZN TOB7Z-63 circuit breaker, follow these general maintenance guidelines:

  • Regular Cleaning: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning.
  • Connection Checks: Periodically inspect all wiring connections to ensure they are tight and secure. Loose connections can lead to overheating or malfunction.
  • Ventilation: Ensure that the installation area maintains adequate ventilation to prevent heat buildup.
  • Operational Check: Occasionally perform a manual switch operation (without load if possible) to ensure the mechanism moves smoothly and indicators function correctly.

7. Troubleshooting

The TOB7Z-63 is designed to automatically protect your system. If you encounter issues, consider the following:

  • Automatic Cut-off: If the circuit breaker automatically trips (cuts off the circuit), it indicates an overload or short circuit condition. Investigate the connected load for faults or excessive current draw. Do not attempt to force the switch back on without resolving the underlying issue.
  • Unexpected Tripping During Switching: If the breaker trips immediately when attempting to switch between sources, double-check your wiring according to the diagram. Ensure that the load is appropriate for the selected power source and that there are no existing faults in the system.
  • No Indication: If the red or green indicators are not functioning, verify power supply to the unit and check for any visible damage.

8. User Tips

  • Many users find this switch highly effective for managing power from solar PV systems, allowing seamless switching between different arrays or power sources.
  • It is particularly useful for applications requiring the transfer of power between two separate DC arrays or PV inverters to a single system.
  • The robust material and reliable transfer mechanism have been positively noted by users.

9. Regulations and Certifications

This TOMZN TOB7Z-63 circuit breaker complies with the following European regulations and harmonized standards:

  • CE Certification: Indicates conformity with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA).
  • Low Voltage Directive (LVD) 2014/35/EU: Ensures electrical equipment within certain voltage limits provides a high level of protection for European citizens.
  • Electromagnetic Compatibility (EMC) Directive 2014/30/EU: Regulates the electromagnetic compatibility of equipment.
  • Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU: Restricts the use of specific hazardous materials in electrical and electronic products.
CE certification mark on the circuit breaker.

The CE mark on the product signifies its compliance with relevant European directives.

10. Warranty and Support

For any technical assistance, warranty claims, or further inquiries, please contact the TOMZN Official Store or your point of purchase.

An official user manual in PDF format is available for download: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.