1. Overview
The ZOYI ZT-MD1 is a compact, digital LCR tweezers bridge tester designed for precise measurement of electronic components. Powered by a lithium polymer battery, it offers extended operation and standby time. The device features an OLED display for clear readings and intelligently identifies and accurately measures resistance, capacitance, and inductance across a wide range with high precision. Its portable design and flexible measuring arms with detachable gold-plated tips ensure reliable operation, making it suitable for various SMD and other LCR parameter measurements.
The ZT-MD1 includes a user calibration learning mode, allowing for calibration based on standard resistors. Factory calibration data can be restored by resetting to factory settings if needed.

Figure 1: ZOYI ZT-MD1 LCR Bridge SMD Test Clip highlighting key features and measurement ranges.
2. Safety Precautions
To prevent electric shock, fire, or personal injury, please read the following precautions carefully:
- Do not apply input voltage during measurement. Do not measure 'live circuits'. Disconnect power before online measurement and ensure all capacitors in the circuit are discharged.
- Discharge capacitors before measuring capacitance.
- Avoid prolonged use or storage in high temperature, high dust, or direct sunlight environments.
- Do not use this product in explosive gas, vapor, or humid environments.
3. Package Contents
Please check the package for the following items:
- 1 x LCR Tweezers Bridge Tester (ZT-MD1)
- 1 x Storage Bag
- 1 x Color Box
- 1 x User Manual
- 1 x USB Type-C Charging Cable
- 1 x Extra Complimentary Pair of Tweezer Clips

Figure 2: Contents of the ZOYI ZT-MD1 package.
4. Setup
4.1. Charging the Device
The ZOYI ZT-MD1 is equipped with a built-in 400mA lithium battery, providing sustainable operation for up to 12 hours. It features a Type-C charging interface.
- When the battery icon in the top right corner of the screen shows one red bar after prolonged use, it needs to be charged promptly. If continued use persists until the battery shutdown voltage is reached, the buzzer will emit intermittent beeps and then shut down automatically.
- Insert the Type-C data cable to connect the tweezer meter to a DC 5V output adapter or USB port on a computer to begin charging.
- During charging, the charging indicator light will remain solid red. When fully charged, the indicator light will change from red to blue.
Note: Do not exceed the charging voltage range of DC 5V.

Figure 3: ZOYI ZT-MD1 connected for charging via its Type-C USB port.
4.2. Replacing Tweezer Clips
The ZT-MD1 features a replaceable tweezer clip design. If the tweezer tips show signs of wear, oxidation, or damage, they can be replaced:
- Loosen the screw on each tweezer tip using a suitable screwdriver.
- Align the new tweezer clips with the slot and insert them.
- Tighten the screw securely.

Figure 4: Steps for replacing the tweezer clips.
5. Operating Instructions
5.1. Operation Panel and Button Functions
The ZT-MD1 features an intuitive control panel with several buttons for various functions:

Figure 5: ZOYI ZT-MD1 Button Instructions and display areas.
- Power Button (MODE):
- Short press to turn on.
- Long press for 2 seconds to turn off.
- In measurement interface, short press to switch between AUTO, L, C, R, Diode, and Continuity measurement modes.
- In settings interface, short press to confirm functions or exit.
- Right Arrow Key (FREQ/MENU):
- In measurement interface, short press to select the parameter to adjust (highlighted with a white frame).
- Long press to enter or exit the settings interface.
- In settings interface, short press to move down the menu and adjust parameters.
- Left Arrow Key (HOLD/LEVEL):
- In measurement interface, short press to hold the current value.
- When the white frame appears, short press to adjust the parameter within the frame.
- Long press to switch measurement voltage.
- In settings interface, short press to move up the menu and adjust parameters.
5.2. Navigating Menus and Settings
- Long press the Right Arrow Key to enter the settings interface.
- Use the Left or Right Arrow Key to select the menu item (e.g., Language, Volume, Backlight).
- Press the Power Button to confirm your selection. The selected menu item will turn yellow.
- Use the Left or Right Arrow Key to adjust the parameter.
- Press the Power Button to confirm and exit the parameter adjustment.
- To exit the settings interface, long press the Right Arrow Key or power off the device.
5.3. Calibration Instructions
When calibration is needed, follow these instructions. Calibration includes 0Ω, 1Ω, 10Ω, 100Ω, 1KΩ, 10KΩ, 100KΩ, 1MΩ, 10MΩ, OPEN, and individual range calibration.
- Enter the settings interface, select the 'Calibration Settings' menu, and short press the Power Button to confirm. The calibration settings menu will turn yellow, and the screen will prompt 'Waiting for calibration.'
- Short press the Right Arrow Key to select the range to be calibrated. The corresponding range value will appear in the middle column of the right side of the screen.
- Fully contact both ends of the standard resistor with the tweezer tips, then press the Left Arrow Key. The screen will prompt 'Calibrating.'
- Wait patiently for 20 seconds. When calibration is complete, the buzzer will beep once, and the screen will display 'Calibration successful.' If the calibration value is incorrect, the buzzer will beep twice, and the screen will display 'Calibration failed.'
Notes:
- Use chip carbon film resistors for calibration, not wire-wound resistors.
- For 0Ω calibration, short-circuit the tweezer tips completely together.
- For OPEN calibration, do not connect any resistor, keeping the tweezer tips in an open circuit state.
- To return to factory calibration data, perform a factory reset.
5.4. Measurement Modes
The ZT-MD1 supports various measurement modes, including automatic component identification.
Video 1: Product demonstration showing various measurement modes and features.

Figure 6: Examples of measuring capacitance, inductance, resistance, and continuity.
5.4.1. Measuring Resistance
- Use the AUTO mode or manually switch to the 'R' mode.
- Contact both ends of the resistor to be tested with the tweezer tips.
- Read the measurement value displayed on the screen.
Notes:
- Ensure full contact with the surface when measuring low resistance. Surface oxidation can affect measurement accuracy.
- If the measurement value exceeds the range, the screen will display 'OL'.
5.4.2. Measuring Capacitance
- Use the AUTO mode or manually switch to the 'C' mode.
- Contact both ends of the capacitor to be tested with the tweezer tips.
- Read the measurement value displayed on the screen.
Notes:
- Discharge the capacitor before measurement to avoid damaging the instrument.
- If the measurement value exceeds the range, the screen will display 'OL'.
- For measuring capacitors above 10µF, selecting a frequency of 1kHz or 100Hz is more suitable; for measuring capacitors below 10nF, a frequency of 1kHz or 10kHz is more appropriate.
5.4.3. Measuring Inductance
- Use the AUTO mode or manually switch to the 'L' mode.
- Contact both ends of the inductor to be tested with the tweezer tips.
- Read the measurement value displayed on the screen.
Notes:
- For measuring inductors above 50mH, selecting a frequency of 1kHz or 100Hz is more suitable; for inductors below 50µH, a frequency of 1kHz or 10kHz is more appropriate.
- Due to frequency limitations, measurements of multilayer chip inductors are for reference only and may not meet accuracy requirements.
5.4.4. Measuring Diodes
Manually switch to the 'Diode' mode. Contact the positive and negative terminals of the diode with the tweezer tips, and read the diode's polarity and voltage value.
Notes:
- Determine the diode's polarity according to the diode symbol direction displayed on the screen and the corresponding measurement object with the tweezer tips.
- The product's diode forward voltage measurement value is for reference comparison only, with a measurement range of Vf 0.1V-0.6V. Values beyond this range will display 'OL'. For higher measurement requirements, select a more professional diode measuring instrument.
5.4.5. Continuity Measurement
Switch manually to the 'Continuity' mode. Touch the tweezer tips to both ends of the point to be tested. A beep will sound when the circuit is closed, and observe the measurement reading on the screen.
Note: Due to the influence of parallel capacitors during online measurement, continuity measurement results are for reference comparison only and should not be used as a standard for determining continuity.
5.5. Data Hold
During measurement, short press the Left Arrow Key (HOLD/LEVEL) to hold the current value on the display. Press again to release.
6. Maintenance
6.1. Cleaning
Clean the device with a damp cloth. Do not use corrosive agents or solvents. Dust or moisture in the test ports may affect reading accuracy.
6.2. Firmware Upgrade
- With the device powered off, press and hold the Left Arrow Key, then simultaneously press the Power Button. The screen will display 'USB-Boot' prompt.
- Connect the Type-C data cable to the computer. The computer will recognize the LCR meter as a disk.
- Drag the prepared upgrade file into the LCR meter disk. The upgrade will proceed automatically.
- The screen will automatically switch to the measurement interface upon successful upgrade.
7. Troubleshooting
- Device not turning on: Ensure the battery is charged. Connect to a power source using the Type-C cable.
- Inaccurate readings: Ensure proper contact with components. Clean tweezer tips if oxidized or dirty. Perform calibration if necessary.
- 'OL' displayed: The measured value is out of the device's range for the current setting.
- Screen not responding: Try restarting the device by turning it off and on. If issues persist, ensure the battery is charged.
- Transaction failed but money deducted: This is an order-related issue, not a device malfunction. Please contact your payment provider or the seller's customer support for assistance.
8. Specifications

Figure 7: Detailed Technical Specifications for ZOYI ZT-MD1.
General Technical Specifications
- Display: OLED
- Range: Automatic
- Testing Rate: 1 time/second
- Data Hold: Yes
- Language Selection: Chinese, English
- Screen Orientation: Left, Right
- Volume Setting: 0%~100%
- Backlight Brightness: 10%~100%
- Auto Power Off: Off, 5 Min, 120 Min
- Calibration Setting: 0Ω-10MΩ, OPEN
- Restore to Factory Default Settings: Yes
- Firmware Upgrade: Yes
- Low Battery Indicator: Yes
Mechanical Technical Specifications
- Dimensions: 146*30*18mm
- Weight: 37g
- Battery Type: Lithium polymer rechargeable battery 3.7V 400mAh
- Material: ABS
Environmental
- Operating Environment: Temperature 0~40°C, Humidity <75%
- Storage Environment: Temperature -20~60°C, Humidity <80%
9. User Tips
- Users appreciate the device's accuracy and convenience for measuring small SMD components.
- The built-in battery is efficient and provides good usage time.
- The interface might take a little getting used to, but it becomes intuitive quickly.
- It's a valuable tool for quick measurements and servicing devices.
- Ensure the firmware is up-to-date for optimal performance.
10. Warranty and Support
10.1. Limited Warranty and Scope of Rights and Responsibilities
From the date of purchase, this product is covered by a one-year warranty, excluding damages caused by accidents, negligence, misuse, modification, contamination, and abnormal operating environments.
This manual is subject to change without prior notice. The contents of this manual are believed to be accurate. If users find any errors or omissions, please contact the manufacturer.
The company is not liable for accidents and damages caused by user error.
The functions described in this manual are not intended to justify the use of the product for special purposes.