1. Product Overview
The JIKONG JK-BD4A17S4P Smart Active Battery Management System (BMS) is designed for large capacity series lithium battery packs. It features voltage acquisition, high current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS remote functions. This BMS is compatible with lithium iron phosphate, ternary lithium, and lithium titanate battery types.
The protection board utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a maximum continuous 0.4A balance current. This high-current active equalization technology ensures battery consistency, improves battery range, and extends battery life.
A mobile APP (supporting Android and iOS) is available for connecting to the protection board via Bluetooth. The APP allows users to check battery status, modify working parameters, and control charge/discharge switches. Its compact size, simple operation, and comprehensive functions make it suitable for various applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.




2. Functional Characteristics
The JIKONG JK-BD4A17S4P BMS offers a wide range of functional characteristics:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support heating function (Optional)
- Support GPS communication
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection




3. Specifications
3.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage | 20-100 | V |
| Operating power consumption | <800 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 24 | String |
| Maximum balancing current | 0.4 | A |
| Maximum charging current | 40 | A |
| Maximum discharge current | 40 | A |
| Maximum instantaneous current | 80 | A |
| Maximum internal loop resistance | 2.8 | mΩ |
| Protective plate size | 116*103*17.6 | mm |
| Finished weight | 205 | g |
3.2. Default Parameters
| Parameter | Li-ion | LiFePO4 | LTO | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 0.4 | 0.4 | 0.4 | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Single overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Single undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 30 | 30 | 30 | S |
| Charge overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | μS |
| Short circuit protection release time | 30 | 30 | 30 | S |
| Charging overtemperature protection temperature | 70 | 70 | 70 | °C |
| Charge overtemperature restore temperature | 60 | 60 | 60 | °C |
| Discharge overtemperature protection temperature | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery temperature | 60 | 60 | 60 | °C |
| Charging low temperature protection temperature | -20 | -20 | -20 | °C |
| Charge low temperature to restore temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature protection temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery temperature | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |

4. Installation & Wiring
4.1. Packing List
Before installation, please verify that all components are present:

4.2. Wiring Method
The JK-BD4A17S4P series protection board is suitable for 7-24 series lithium battery packs. Wiring methods vary depending on the number of cells in the battery pack. Always ensure all connections are secure and correct before powering on the BMS.


4.3. Interface Definition
The BMS features various connectors for different functions:

P1 (HY2.0-15P) - Balance with Acquisition Interface:
- Pin 1: B- (Total negative battery)
- Pin 2-15: B1-B14 (Positive terminals for cells 1-14)
P2 (HY2.0-11P) - Balance with Acquisition Interface:
- Pin 1-7: B15-B21 (Positive terminals for cells 15-21)
- Pin 8-10: B22-B24 (Positive terminals for cells 22-24)
- Pin 11: B+ (Protection board power supply, connected to the battery)
P3 (HY2.0-4P) - Temperature Interface:
- Pin 1: T1A (First temperature sensor pin A)
- Pin 2: T1B (First temperature sensor pin B)
- Pin 3: T2A (Second temperature sensor pin A)
- Pin 4: T2B (Second temperature sensor pin B)
P4 (HY2.0-4P) - 4 External Optional Temperature Interface:
- Pin 1: T3A (Third temperature sensor pin A)
- Pin 2: T3B (Third temperature sensor pin B)
- Pin 3: T4A (Fourth temperature sensor pin A)
- Pin 4: T4B (Fourth temperature sensor pin B)
P5 (1.25T-4PWT) - GPS Interface:
- Pin 1: GND (Power/signal ground)
- Pin 2: RX (UART_RX, 3.3V)
- Pin 3: TX (UART_TX, 3.3V)
- Pin 4: VGPS (Power output, voltage close to B+)
P6 (A1254WF-2A) - Buzzer Interface (Optional):
- Pin 1: GND (Buzzer power negative)
- Pin 2: VCC (Buzzer power supply positive)
P7 (A1254WF-4A) - Communication Interface (Optional):
- Pin 1: CAN L (CAN signal negative terminal)
- Pin 2: CAN H (CAN signal positive terminal)
P8 (A1254WF-6A) - Display Interface:
- Pin 1: K- (Activation signal negative electrode)
- Pin 2: K+ (Activation signal positive)
- Pin 3: GND (Negative terminal)
- Pin 4: B (Display RS485 signal negative)
- Pin 5: A (Display RS485 signal positive)
- Pin 6: VCC (Display power output)
P9 (A1254WF-3A) - Parallel Interface (Optional):
- Pin 1: P-status (Parallel module status signal)
- Pin 2: P-EN (Parallel module enable signal, output low level to turn on parallel module)
- Pin 3: GND (Signal ground)
Heating Wire (16AWG-Orange-15CM) (Optional):
- Pin 1: HT- (Heater element negative electrode)
4.4. Device Activation
Before powering on the protection board, ensure the balance cables are properly connected and that the P- and B- terminals are correctly connected. Verify that the protection board is securely fixed to the battery cells. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a physical power-on switch. It is designed for charging activation mode: after battery assembly, connect a charger (with voltage 2V higher than battery voltage) to activate the BMS.
Key activation and display activation are also supported. If using a display screen and button, simply insert the cable into the display interface and press the button to activate.
5. Operation Instructions
5.1. APP Installation and Parameter Setting
To download the mobile APP, scan the QR code below. The Android APP requires Android Version 7 or higher.

Once the APP is installed, you can connect to the BMS via Bluetooth to view battery information and adjust various parameters. For detailed parameter settings, refer to the 'Instructions for Setting Protection Board Parameters' document (PDF).

5.2. Active Equalization
The BMS uses active equalization to transfer energy from higher voltage cells to lower voltage cells. Before using this function, set basic battery parameters (battery type, number of cells, battery capacity, trigger equalization differential pressure, voltage calibration, current calibration) in the APP. The default balance current is 0.4A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. If not needed, the balancing function can be turned off in the APP.

5.3. Protection Functions
The BMS includes several standard protection features, configurable via the APP:
- Charge Overvoltage Protection: Prevents overcharging by shutting off charging when any cell exceeds the set overvoltage protection voltage. Charging resumes when all cells drop below the recovery voltage.
- Discharge Undervoltage Protection: Prevents over-discharging by shutting off discharge when any cell drops below the set undervoltage protection voltage. Discharge resumes when all cells rise above the recovery voltage. Automatic shutdown occurs if any cell drops below the automatic shutdown voltage.
- Charge Overcurrent Protection: Shuts off charging if the current exceeds the set continuous charging current for a specified delay. Charging resumes after the overcurrent release time.
- Discharge Overcurrent Protection: Shuts off discharge if the current exceeds the set continuous discharge current for a specified delay. Discharge resumes after the overcurrent release time. The maximum continuous discharge current is 40A.
- Over Temperature Protection: Shuts off charging/discharging if the BMS detects temperatures above the set limits. Operation resumes when temperatures return to safe levels.
- Low Temperature Protection: Shuts off charging if the BMS detects temperatures below the set limits. Charging resumes when temperatures rise to safe levels. For extremely cold areas, the optional heating function is recommended.
- Short Circuit Protection: Automatically triggers with a default delay and recovery time. If short circuit protection is triggered upon initial connection of a charger or load, increasing the protection delay in the APP may resolve issues caused by high peak currents or large load capacitance.
5.4. Additional Functions
- Heating Function (Optional): Heats the battery at low temperatures to prevent reduced activity. Designed for a 10A heating current. Control via APP. A secondary temperature control switch (45-65°C) in series is recommended.
- Alarm Function (Optional): Provides alerts for safety risks like overtemperature, overcharge, and overdischarge.
- Battery Parallel Function (Optional): Supports parallel battery packs. Requires parallel modules and disabling 'charging current limiting' in the APP.
- Emergency Switch: A standard feature that allows 30 minutes of simultaneous charge and discharge operation in critical situations (e.g., over-temperature, over-discharge, over-charge, cell drop) to prevent system failure.
- Intelligent Sleep: A standard feature that can be enabled/disabled via the APP. The BMS enters sleep mode (shuts down) if charge/discharge current is less than 1A for 26 consecutive hours, reducing self-consumption. It can be reactivated by a button or charger.
- Communication Function (Optional): Supports CAN and RS485. Configurable via the APP for address and protocol. Refer to the Jikong Protection Board communication protocol document for details.


6. Maintenance
The JIKONG BMS is designed for durability and reliability. Regular maintenance primarily involves ensuring proper connections and monitoring performance via the APP.
- Connection Checks: Periodically inspect all wiring, especially balance cables and main power connections (P- and B-), for looseness, corrosion, or damage.
- Firm Mounting: Ensure the BMS remains securely fixed to the battery pack to prevent vibration-induced damage.
- Software Updates: Keep the mobile APP updated to the latest version to benefit from new features, bug fixes, and improved performance.
- Parameter Review: Occasionally review the BMS parameters in the APP to ensure they are still appropriate for your battery configuration and usage patterns.
- Environmental Conditions: Operate the BMS within its specified temperature range (-30°C to 70°C). If operating in extreme cold, utilize the optional heating function to protect battery cells.
7. Troubleshooting
If you encounter issues with your JIKONG JK-BD4A17S4P BMS, consider the following:
- BMS Not Activating: Ensure the balance cables are correctly connected and the P- and B- terminals are secure. The BMS activates via charging (charger voltage 2V higher than battery voltage) or by pressing a button if a display is connected.
- Frequent Short Circuit Protection: If short circuit protection triggers upon initial connection of a charger or load, it might be due to high peak currents or large load capacitance. Try increasing the short circuit protection delay in the APP settings.
- Protection Triggered (Overvoltage, Undervoltage, Overcurrent, Overtemperature): Check the battery cell voltages, currents, and temperatures via the APP. Adjust the protection and recovery parameters if necessary, ensuring they are within safe limits for your battery type.
- Communication Issues: Ensure Bluetooth is enabled on your mobile device and the BMS. If using optional CAN/RS485, verify the physical connections and check the communication protocol settings in the APP.
- Unusual Behavior/Burning Smell: Immediately disconnect power from the battery pack and BMS. This indicates a serious issue, likely a wiring error or component failure. Do not re-energize until the problem is identified and resolved.
8. User Tips
- Always double-check all wiring connections before applying power to prevent damage to the BMS or battery pack.
- For optimal battery life, ensure your active balancing current is set appropriately, ideally not exceeding 0.2C of your battery's capacity.
- In cold environments, consider using the optional heating function to maintain battery performance and longevity.
- Regularly monitor your battery's health and BMS parameters through the mobile APP for proactive maintenance.
9. Support & Documentation
For more detailed information, including comprehensive parameter settings and advanced troubleshooting, please refer to the official user manual PDF:
For further assistance, please contact JIKONG Smart BMS Store customer support.