Jiayin JYPC-3

Contents

Jiayin JYPC-3 Electromagnetic Pump User Manual

Model: JYPC-3

1. Safety Instructions

  • Power-Off Operation: Always disconnect the power supply before any maintenance, installation, or shutdown procedures.
  • No Dry Running: Do not operate the pump without liquid. Dry running can cause severe damage to the pump.
  • Liquid Only: Use only clean, particle-free liquid. Impurities can cause clogging and damage to the pump mechanism.

General Warnings

  • CHOKING HAZARD: This product may contain small parts. Keep away from children under 3 years of age.

2. Setup and Installation

Mounting

  • Vertical Mounting: Ensure the pump is installed in a stable and upright position to ensure proper operation and prevent damage.

Connections

  • Inlet/Outlet Sealing: Ensure all connections at the inlet and outlet are properly sealed to prevent liquid leakage.
  • Inlet Filtration: Install a suitable filter at the pump's inlet to prevent impurities from entering the pump and causing blockages or damage.

Wiring Diagram

Refer to the diagram below for electrical connections. Ensure correct polarity and secure connections.

Wiring diagram for Jiayin JYPC-3 pump showing electrical terminals and fluid connections.
Figure 1: Wiring diagram. The image highlights the electrical connection points (two flat terminals) and the fluid inlet/outlet ports.

3. Operating Instructions

The Jiayin JYPC-3 is an electromagnetic pump designed for applications requiring precise liquid transfer, such as coffee machines. Ensure the pump is correctly installed and connected to a power source within its specified voltage range (220-240V AC).

  • Power On: Once installed and filled with liquid, apply power to the pump. The pump will begin to operate, transferring liquid.
  • Power Off: Disconnect power to stop the pump.
  • Continuous Operation: This pump is designed for continuous operation (ED100%).

Product Video Overview

Video 1: A brief overview of the Jiayin JYPC-3 electromagnetic pump, showcasing its design and components.

4. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your pump.

  • Filter Cleaning: Periodically inspect and clean the inlet filter to prevent blockages and maintain proper flow.
  • Seal Replacement: If low pressure is observed, inspect and replace worn seals.
  • Pump Cleaning: If the pump becomes excessively noisy or performance degrades, it may require internal cleaning. Consult a qualified technician if unsure.
  • Plunger Replacement: In cases of persistent issues, the plunger may need to be replaced.

5. Troubleshooting

  • No Liquid Output:
    • Bleed any trapped air from the system.
    • Clean the inlet filter for obstructions.
    • Check the power supply to ensure it is connected and providing the correct voltage.
  • Low Pressure:
    • Replace any worn or damaged seals.
    • Tighten all tubing connections to prevent leaks.
    • Remove any debris that may be partially blocking the flow path.
  • Excessive Noise:
    • Reinforce the pump's mounting to reduce vibrations.
    • Clean the pump internally if debris is suspected.
    • Consider replacing the plunger if noise persists after cleaning and mounting checks.

6. Specifications

FeatureSpecification
Product ModelJYPC-3
Power SourceElectric
TheoryElectromagnetic Pump
StructureBooster Pump
VoltageAC 220V-240V
Power25W
Frequency50Hz
Maximum Pressure6.5 bar
Average Flow Rate120-220 cc/min (ml/min)
Noise Level55 dB (Max) / 43 dB (Typical)
UsageWater
MaterialCast steel
CertificationCE
Duty CycleED100% (Continuous)

Dimensions

Dimensions of Jiayin JYPC-3 pump showing length, height, and body width.
Figure 2: Overall dimensions of the JYPC-3 pump. Length: 94mm, Overall Height: 47mm, Body Height: 39mm.
Detailed technical diagram of Jiayin JYPC-3 pump with internal dimensions and port sizes.
Figure 3: Detailed technical diagram. Overall length: 90mm, Body width: 44mm, Inlet/Outlet diameter: Ø6.5mm, Electrical terminal size: 4.8x0.8mm.

7. User Tips

  • Always ensure the pump is primed with liquid before starting to prevent airlocks and dry running.
  • Regularly check for any signs of leaks around connections and address them promptly.
  • For optimal performance in coffee machines, use filtered water to minimize mineral buildup and extend pump life.

8. Warranty and Support

For warranty information, please refer to the terms provided by your seller at the time of purchase. For technical support or further inquiries, please contact your retailer or the manufacturer.

An additional user manual in PDF format may be available for download from the seller's product page or directly from the manufacturer. (Reference: User Manual PDF)