Sugon 3010PM

Contents

Sugon 3010PM DC Power Supply User Manual

Model: 3010PM

1. Product Overview

The Sugon 3010PM is a professional 30V 10A DC power supply designed for various electrical applications, including charging, powering on, testing, and maintenance. It features precise voltage and current regulation, multiple protection mechanisms, and convenient USB outputs.

Front view of the Sugon 3010PM DC Power Supply
Figure 1: Front view of the Sugon 3010PM DC Power Supply
Labeled diagram of Sugon 3010PM DC Power Supply with dimensions and controls
Figure 2: Labeled diagram of the Sugon 3010PM DC Power Supply, showing dimensions and control functions.

Key Features:

  • Continuously adjustable voltage output (DC 0.001V - 31V)
  • Continuously adjustable current output (0.001A - 10.5A)
  • 4 sets of memory buttons for storing voltage, current, and protection settings.
  • Overvoltage, Overcurrent, and Short-Circuit Protection.
  • Extra-Large Toroidal Transformer for stable and durable operation.
  • 6 adjustable USB outputs (0V-30V) synchronized with main output.
  • 2 fixed 5V/2A USB outputs for charging mobile devices.
  • HD Digital Display for clear monitoring of voltage, current, and power.
  • Buzzer for operational feedback.

2. Setup

2.1 Unpacking and Inspection

Carefully remove the power supply from its packaging. Inspect the unit for any signs of damage during transit. Ensure all accessories are present:

  • Sugon 3010PM DC Power Supply
  • Power Cable
  • User Manual (this document)
Sugon 3010PM packaging and included accessories
Figure 3: Product packaging and included accessories.

2.2 Power Connection

  1. Ensure the power switch on the front panel is in the OFF position.
  2. Connect the provided power cable to the power input socket on the rear of the unit.
  3. Plug the other end of the power cable into a suitable 110V or 220V AC power outlet, depending on your model's voltage specification.
  4. Place the power supply on a stable, level surface with adequate ventilation.

3. Operating Instructions

3.1 Powering On/Off

Press the 'POWER' switch on the front panel to turn the unit ON or OFF.

3.2 Voltage and Current Regulation

Diagram showing voltage and current adjustment knobs and lock/unlock function
Figure 4: Voltage and Current Adjustment Knobs, and Lock/Unlock Function.
  • Voltage Adjustment: Twist the 'V' voltage knob to adjust the voltage output. Press the 'V' voltage knob to cycle through the digits; the corresponding digital indicator will flash. Twist the knob to set the desired voltage.
  • Current Adjustment: Twist the 'A' current knob to adjust the current output. Press the 'A' current knob to cycle through the digits; the corresponding digital indicator will flash. Twist the knob to set the desired current.

3.3 Lock/Unlock Function

To prevent accidental changes to settings:

  • Lock: Long press the 'V' voltage knob. The lock indicator light will turn on, indicating the unit is locked.
  • Unlock: Long press the 'V' voltage knob again. The lock indicator light will turn off, releasing the lock state.

3.4 Memory/Save Functions (M1-M4)

Diagram showing the 4 storage channels (M1-M4) for saving settings
Figure 5: The 4 storage channels (M1-M4) allow saving and recalling different voltage and current settings.
  • Save Settings: Press and hold one of the channel buttons (M1, M2, M3, M4) for two seconds until you hear two beeps. The current voltage, current, and protection settings will be stored in that channel.
  • Recall Settings: Press the desired channel button (M1, M2, M3, M4) once to recall the stored settings.

3.5 Overcurrent Protection Modes

Diagram showing continuous and single-time overcurrent protection buttons
Figure 6: Continuous Overcurrent Protection (CONT OCP) and Single-Time Overcurrent Protection (ONCE OCP) buttons.
  • Continuous Overcurrent Protection (CONT OCP): Press the 'CONT OCP' button. The indicator light will turn on. This mode automatically restores power supply output after an overcurrent event. It is suitable for general use.
  • Single-Time Overcurrent Protection (ONCE OCP): Press the 'ONCE OCP' button. The indicator light will turn on. This mode is suitable for sensitive circuits that cannot withstand multiple current surges. After a single overcurrent event, the indicator flashes, and the power supply output is cut off until the 'ONCE OCP' button is pressed again to restart the function.

3.6 Constant Current Mode

Press the 'Constant Current Mode' button. Both the continuous and single-time overcurrent protection indicators will turn off. In this mode, the power supply continuously outputs voltage and current without overcurrent protection. Use with caution.

3.7 8.4V Limited Function

For models equipped with this feature, activating the 8.4V limited function restricts the maximum output voltage to 8.4V. This helps minimize potential damage from operational errors when working with sensitive components.

3.8 USB Outputs

Diagram showing adjustable and fixed USB output ports
Figure 7: Adjustable USB outputs (0V-30V) and Fixed 5V/2A USB outputs.
  • Adjustable USB Outputs (6 ports): These outputs can provide voltage from 0V to 30V, synchronized with the main output settings. You can monitor the charging voltage, current, and power status through the main display. Ensure safe voltage and current limits are set in advance.
  • Fixed USB Outputs (2 ports, 5V/2A): These ports provide a stable 5V/2A output, ideal for charging mobile phones and other 5V devices.

3.9 Buzzer Settings

In the locked state, long press the current 'A' button to toggle the buzzer sound ON or OFF.

3.10 Display Brightness Adjustment

In normal operating mode, press and hold the M1 and M2 memory buttons simultaneously. The display will show '8888' and the current brightness level. Turn the current knob to adjust the display brightness. Once the desired brightness is achieved, press the current knob to save and exit.

3.11 Restore Factory Settings

In the locked state, press and hold the M1 and M2 memory buttons simultaneously. After a long beep, '5E' will be displayed, indicating that the factory default parameters for memory keys M1, M2, M3, and M4 have been restored.

3.12 Video Demonstration

Video 1: A demonstration of the Sugon 3010PM DC Power Supply's features, including adjustable voltage/current, memory functions, and USB outputs for charging and powering devices.

4. Maintenance

4.1 Voltage Calibration

If voltage calibration is required:

  1. Carefully remove the 'A' current knob.
  2. Insert a small flat-blade screwdriver into the exposed adjustment screw.
  3. Gently rotate the screwdriver to calibrate the voltage as needed.
  4. Replace the 'A' current knob.

4.2 General Care

  • Keep the unit clean and free from dust. Use a soft, dry cloth for cleaning.
  • Ensure proper ventilation around the unit to prevent overheating.
  • Avoid exposing the unit to moisture, extreme temperatures, or direct sunlight.
  • Do not attempt to open the casing or perform repairs yourself, as this may void the warranty and pose safety risks.

5. Troubleshooting

5.1 Protection Mechanisms

Diagram highlighting overvoltage, overcurrent, and short-circuit protection features
Figure 8: Built-in protection features: Overvoltage, Overcurrent, and Short-Circuit Protection.
  • Overvoltage Protection: If the output voltage exceeds a safe limit, the unit will automatically shut down or limit the voltage to prevent damage to the connected device.
  • Overcurrent Protection: If the output current exceeds the set limit, the unit will activate the selected overcurrent protection mode (Continuous OCP or Once OCP).
  • Short-Circuit Protection: In case of a short circuit at the output terminals, the unit will immediately cut off the output to prevent damage to the power supply and the connected circuit.

5.2 Common Issues

ProblemPossible CauseSolution
No power/displayPower cable not connected, power switch off, power outlet fault.Check power cable, ensure switch is ON, test power outlet.
No output voltage/currentOutput switch OFF, protection activated, incorrect settings.Press output switch, check OCP/OVP indicators, verify voltage/current settings.
Inaccurate voltage/current readingsNeeds calibration.Perform voltage calibration as described in Section 4.1.
Buzzer constantly beepingProtection activated (e.g., overcurrent).Check for overcurrent condition, adjust load or settings. Disable buzzer if desired (Section 3.9).

6. Specifications

AttributeValue
Model NumberSugon 3010PM
MaterialStainless steel
TypeCombination
DIY SuppliesElectrical
Voltage110V/220V
Net Weight6.9 kg
Gross Weight7.7 kg
Dimensions (L x W x H)35 cm x 25 cm x 24 cm (approximate)
Transformer TypeExtra-Large Toroidal Transformer

7. User Tips

  • When working with sensitive electronics, always start with lower voltage and current settings and gradually increase them to avoid damage.
  • Utilize the memory channels (M1-M4) to quickly switch between frequently used voltage and current configurations.
  • For circuits that are prone to short-term current spikes, consider using the 'Continuous Overcurrent Protection' mode. For highly sensitive circuits, 'Single-Time Overcurrent Protection' offers a more cautious approach.
  • The adjustable USB outputs are versatile for powering various devices, but remember to set appropriate voltage and current limits to match the device's requirements.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.