1. Introduction
The GEYA SUL180N is a 24-hour analog mechanical timer switch designed for automatic control of various electrical equipment. It allows users to set specific times for devices to turn on and off, making it ideal for applications such as street lighting, neon signs, production equipment, agricultural systems, warehouse ventilation, and preheating systems.
Figure 1: GEYA SUL180N Mechanical Timer Switch with LED indicator.
2. Safety Information
Please read this manual carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or damage to the device.
- All electrical work should be performed by a qualified electrician in accordance with local and national electrical codes.
- Ensure the power supply is disconnected before any installation, wiring, or maintenance.
- Do not expose the device to moisture or extreme temperatures outside its specified operating range.
- The SUL180N contains a non-removable battery for power reserve. Do not attempt to open or replace the battery.
- Before initial use, charge the timer for at least 2 hours to ensure the power reserve battery functions normally.
- Dispose of the product responsibly at the end of its life, following local regulations for electronic waste, due to its internal battery.
3. Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | SUL180N |
| Theory | Mechanical |
| Operating Voltage | 85V~250VAC |
| Rated Frequency | 45~60Hz |
| Power Consumption | 0.5W |
| Switching Contact | 16(4)A 250V AC |
| Drive | Quartz-controlled stepper motor |
| Power Reserve | 100 hours |
| Program | Daily program |
| Minimum Setting Unit | 15 Minutes |
| Number of Switching Segments | 96 |
| Installation Method | DIN Rail |
| Type of Connection | Screw Terminals |
| Protection Degree | IP20 |
| Protection Class | II according to EN 60730-1 |
| Ambient Temperature | -10℃ to +50℃ |
| Dimensions (W x H x D) | 18mm x 90mm x 68mm (approx.) |
For detailed dimensions, refer to Figure 2.
Figure 2: Dimensions of the SUL180N Timer Switch.
4. Installation
The GEYA SUL180N is designed for DIN rail mounting. Ensure the power supply is completely disconnected before proceeding with installation.
4.1 DIN Rail Mounting
- Attach the timer switch to a standard 35mm DIN rail.
- Ensure it is securely clipped into place.
4.2 Wiring Connection
Refer to the wiring diagrams below for proper connection. It is recommended that wiring be performed by a qualified professional.
Figure 3: Wiring connection diagram and DIN rail installation steps.
Figure 4: Basic wiring diagram on the back of the SUL180N.
General Wiring Steps:
- Connect the incoming Live (L) and Neutral (N) wires to the designated input terminals (e.g., L and N).
- Connect the load (e.g., light bulb) to the output terminals (e.g., 1 and 2, or 2 and 3 depending on desired contact state).
- Ensure all connections are tight and secure.
Video Guide: For a visual guide on installation and basic operation, please watch the video below.
Video 1: Installation and basic timing operation of the GEYA SUL180N timer switch.
5. Operation
The SUL180N features a programming dial and a manual mode switch for flexible control.
Figure 5: Programming dial and manual mode switch.
5.1 Setting the Current Time
- Turn the central dial until the current time aligns with the index marker (the small arrow or line on the timer's face).
5.2 Programming On/Off Times
- The dial has multiple pins around its circumference, each representing a 15-minute interval.
- To set an 'ON' period, push the corresponding pins outwards (to the left).
- To set an 'OFF' period, leave the corresponding pins inwards (to the right).
- The timer will activate the connected load during the 'ON' periods and deactivate it during 'OFF' periods.
5.3 Manual Mode
The manual mode switch allows you to override the programmed settings temporarily.
- Automatic Functioning (Clock Symbol): When the switch is set to the clock symbol, the timer operates according to the programmed ON/OFF times.
- Permanent Connection (I Symbol): When the switch is set to 'I', the connected load will remain continuously ON, overriding any programmed OFF periods.
6. Maintenance
- Initial Charge: Before first use, or after a prolonged period of storage, ensure the timer is connected to power for at least 2 hours to fully charge its internal power reserve battery. This battery maintains the time setting during power outages.
- Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Environmental Protection: The SUL180N contains a non-removable battery. When the product reaches the end of its service life, it must be recycled according to local environmental regulations for electronic waste. Do not dispose of it with general household waste.
7. Troubleshooting
- Timer not operating: Check power supply connections. Ensure the internal battery has been charged for at least 2 hours. Verify the manual mode switch is set to 'Automatic Functioning'.
- Load not switching: Check wiring connections to the load. Ensure the pins are correctly set for ON/OFF periods. Verify the manual mode switch is not set to 'Permanent Connection'.
- Time drift: Ensure the timer is receiving continuous power to maintain the power reserve.
8. User Tips
- Battery for Power Reserve: The SUL180N includes an internal, non-removable battery that provides a power reserve of approximately 100 hours. This battery ensures the timer continues to keep time even during power interruptions, so you don't lose your programmed settings. Remember to charge it for at least 2 hours before initial use.
- Compact Design: Users appreciate the small size of the SUL180N, making it suitable for installations where space is limited.
9. Warranty and Support
For detailed warranty information, technical support, or further inquiries, please refer to the official GEYA documentation or contact your retailer.
An official user manual in PDF format is available for download: GEYA SUL180N User Manual (PDF).