1. Introduction
The COMPTYCO AUA-C607/C605 is a versatile and essential tool for fiber optic maintenance and installation. This rechargeable mini optical fiber identification instrument is designed for non-destructive fiber optic identification work. It integrates multiple functions including an Optical Power Meter (OPM), Optical Fiber Identifier (OFI), Visual Fault Locator (VFL), and an LED light source. It can be used to test the light transmission of fiber optic cables with a red light source and detect signals at any position on single-mode and multi-mode fibers. This device helps in quickly identifying and separating specific optical fibers without interrupting live network operations by detecting modulated signals (270Hz, 1KHz, 2KHz) at 1310nm or 1550nm wavelengths.
2. Key Features
- Multifunctional 4-in-1 Design: Combines Optical Power Meter (OPM), Optical Fiber Identifier (OFI), Visual Fault Locator (VFL), and LED illumination.
- Non-Destructive Testing: Performs micro-bending tests without damaging the fiber line.
- Rechargeable Battery: Equipped with a convenient Type-C charging port and a 3.7V 650mAh lithium battery.
- Signal Frequency Identification: Capable of identifying 270Hz, 1kHz, and 2kHz modulated signals.
- High-Precision OPM: Features a 2.5mm universal interface, compatible with SC/FC/ST/LC connectors (optional adapters may be required).
- Concealed VFL + LED: Integrated VFL with ≥10-30mW output power at 650nm wavelength, and an LED light for dark environments.
- Universal Fixture: Suitable for various fiber diameters including 0.25mm, 0.9mm, 2.0mm, and 3.0mm.
- Signal Direction Indication: Screen icons display left and right directional indicators for easy identification.
3. Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 800-1700nm |
| Signal Recognition Type | CW, 270Hz ± 5%, 1kHz ± 5%, 2kHz ± 5% |
| Detector Type | φ 1mm InGaAs 2 pcs |
| Adapted Fiber Type | φ 0.25 / φ 0.9 (bare fibers); φ 2.0, φ 3.0 (for tail fiber) |
| Signal Direction | Screen icon displays left and right directional indicators |
| Signal Frequency Range | 270Hz, 1kHz, 2kHz |
| Measuring Range of Optical Power Meter | -70 ~ +10dBm / -50 ~ +26dBm |
| Probe Type | InGaAs |
| Standard Wavelength (nm) | 850, 980, 1270, 1300, 1310, 1490, 1550, 1577, 1625, 1650 |
| Display Resolution | Linear: 0.1%, Logarithmic: 0.01dBm |
| Working Temperature (°C) | -10 ~ +60°C |
| Storage Temperature (°C) | -25 ~ +70°C |
| Automatic Shutdown Time (min) | 10 minutes |
| Output Optical Power of Red Light Source (VFL) | ≥10-30mW |
| Red Light Source Output Wavelength (VFL) | 650nm |
| Overall Dimensions (mm) | 240 × 47 × 30 |
| Power Supply | Rechargeable lithium battery (3.7V 650mAh) |
4. Package Contents
Upon opening the package, please verify that all items listed below are present and in good condition:
- 1 x COMPTYCO AUA-C607/C605 Optical Fiber Identifier Unit
- 1 x USB Type-C Charging Cable
- 1 x Wrist Strap
- 1 x Carrying Case
- 1 x Certification/Warranty Card (may vary)
5. Setup
5.1 Initial Charging
Before first use, fully charge the device using the provided USB Type-C cable and a compatible USB power adapter (not included). The charging port is located on the side/rear of the device.
5.2 Power On/Off
Press and hold the power button (usually marked with a power symbol) to turn the device on or off. The display will illuminate upon successful power-on.
5.3 Attaching the Wrist Strap
Attach the wrist strap to the designated loop on the device to prevent accidental drops during use.
6. Operating Instructions
6.1 Optical Fiber Identification (OFI)
- Ensure the fiber is clean and free of debris.
- Open the universal fixture on the top of the device.
- Carefully place the optical fiber into the appropriate groove of the fixture, matching its diameter (0.25mm, 0.9mm, 2.0mm, or 3.0mm).
- Close the fixture gently to secure the fiber. The device will perform a non-destructive test.
- Observe the screen for signal presence and direction indicators (left/right arrows). The device can detect CW, 270Hz, 1kHz, and 2kHz modulated signals.
6.2 Optical Power Meter (OPM)
- Connect the optical fiber to the 2.5mm universal interface port (located under the top cover). Ensure the connector type is compatible (SC/FC/ST/LC).
- Press the
MODbutton to cycle through different measurement modes or wavelengths if applicable. - The screen will display the measured optical power in dBm.
- Use the
REFbutton to set a reference power level for relative measurements. - Press the
dB/SAVEbutton to change units or save readings (refer to the PDF manual for detailed saving procedures).
6.3 Visual Fault Locator (VFL) and LED Light
- To use the VFL, open the concealed port (usually a small cover near the top).
- Insert the fiber connector into the VFL port.
- Press the
VFL/LEDbutton to activate the red laser light. - Observe the fiber for light leakage, which indicates breaks or bends.
- Press the
VFL/LEDbutton again to switch to LED illumination or turn off the VFL/LED.
7. Maintenance
- Cleaning: Regularly clean the optical ports and fiber adapters with lint-free wipes and optical cleaning solution to ensure accurate measurements. Dust and debris can significantly affect performance.
- Battery Care: Recharge the device regularly, even if not in frequent use, to maintain battery health. Avoid fully discharging the battery for extended periods.
- Storage: Store the device in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Refer to the storage temperature range in the specifications.
- Avoid Impact: Protect the device from drops and impacts, which can damage internal components or optical interfaces.
8. Troubleshooting
- Device does not power on:
-
- Check battery level. Recharge the device if the battery is low.
- Ensure the power button is pressed and held sufficiently.
- Inaccurate OPM readings:
-
- Clean all fiber connectors and the OPM input port thoroughly.
- Ensure the correct wavelength is selected on the OPM (if applicable).
- Verify the fiber type (single-mode/multi-mode) matches the test setup.
- OFI not detecting signal:
-
- Ensure the fiber is correctly seated in the universal fixture.
- Verify that a signal is present on the fiber and that its modulation frequency (270Hz, 1kHz, 2kHz) is within the device's detection range.
- Check the signal source for proper operation.
- VFL light is dim or not working:
-
- Check battery level and recharge if necessary.
- Ensure the VFL port is clean.
- Verify the VFL/LED button is pressed correctly to activate the VFL.
9. User Tips
No specific user tips were available from customer reviews or Q&A at the time of manual creation. For optimal performance, always ensure fiber ends and optical ports are clean before use.
10. Warranty and Support
For detailed warranty information, technical support, or service inquiries, please refer to the documentation included in your product package or contact COMPTYCO customer service directly.
A comprehensive user manual in PDF format is also available for download or reference: