SUSWE SU-800/900 Series

SUSWE SU-800/900 Series VFD Inverter User Manual

High-Performance Vector Type Frequency Converter for AC380V Three-Phase Motors

1. Safety Information and Notices

Please read this manual carefully before installation, operation, and maintenance to ensure correct and safe use of the product. Keep this manual for future reference.

1.1 Safety Definitions

  • Danger: Indicates a hazardous situation which, if not avoided, could result in serious injury or death. This includes operations not performed according to requirements.
  • Attention: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury, or equipment damage. This includes operations not performed according to requirements.

Any injury or loss caused by operation not in accordance with the requirements is not the responsibility of the manufacturer.

2. Setup and Installation

2.1 Product Overview

The SUSWE SU-800/900 series VFD is a high-performance vector type frequency converter designed for various industrial applications. It features simple wiring, energy saving capabilities, and an IGBT module for enhanced performance.

SUSWE VFD Inverter with features listed
Main product image highlighting features like high-performance, CE FC RoHS, source factory, quality assurance, video teaching, simple wiring, energy saving, IGBT module, EU CE certification, and 1-year warranty.

2.2 Dimensions and Mounting

The VFD units come in various sizes depending on their power rating. Ensure adequate space for installation and ventilation.

C1 external unit dimensions diagram
C1 external unit dimensions (in mm) suitable for models SU800-0R75G2 to SU800-2R2G2 (single-phase 220V) and SU800-0R75G3 to SU900-2R2G3 (three-phase 380V). Installation dimensions A1: 197.2, A2: 74, B1: 187, B2: 89.6, B3: 71.4.
C2 external unit dimensions diagram
C2 external unit dimensions (in mm) suitable for models SU800-0R5G2 to SU800-7R5G2 (single-phase 220V) and SU900-4R0G3 to SU900-7R5G3 (three-phase 380V). Installation dimensions B1: 202, B2: 102, B3: 161.68.
C3 external unit dimensions diagram
C3 external unit dimensions (in mm) suitable for models SU900-7R5G3 to SU900-15R0G3 (three-phase 380V). Installation dimensions B1: 242.5, B2: 125, B3: 169.5.
C4 external unit dimensions diagram
C4 external unit dimensions (in mm) suitable for models SU900-18R5G3 to SU900-22R0G3 (three-phase 380V). Installation dimensions B1: 297, B2: 165, B3: 216.2.
C5 external unit dimensions diagram
C5 external unit dimensions (in mm) suitable for models SU900-18R5G3 to SU900-22R0G3 (three-phase 380V). Installation dimensions A1: 360, A2: 205, B1: 360, B2: 231.7, B3: 231.7.

2.3 Electrical Installation and Wiring

Before installation, read the instructions carefully to prevent dangerous occurrences and improper operation. The wiring is simple and convenient to use.

Wiring diagram for 220V and 380V VFD inverters
Wiring diagram for 220V (single-phase input) and 380V (three-phase input) VFD inverters. Ensure proper grounding and connection to power supply and motor.

2.3.1 Main Circuit Terminals

Terminal MarksNameInstruction
R, S, T / L, NPower supply input terminalsConnection point of three-phase 380V / single-phase 220VAC power supply
P+, PBBrake electric resistance connect terminalsConnect brake electric resistance
U, V, WFrequency converter output terminalsConnect three-phase motor
Grounding terminalsGrounding terminals

2.3.2 Control Circuit Wiring

The control circuit wiring for all 800/900 series inverters is the same. The diagram below shows the three-phase 380V converter wiring diagram, indicating main loop terminals and control loop terminals.

Wiring method of frequency converter control circuit
Figure 2-2: Wiring method of frequency converter control circuit. This diagram illustrates connections for triphase input, braking resistance, motor, multifunctional digital input terminals (X1-X4, HDI), analog output (AO1, GND), open collector output (Y1, COM), high speed pulse output (HDO), DC24V power supply, and RS485 communication (A+, B-).

2.3.3 Control Terminal Functions

For detailed control terminal functions, refer to the PDF manual, pages 10-11. Key terminals include 10V-GND (power supply for external devices), 24V-COM (power supply for digital input/output), AI1-GND, AI2-GND (analog inputs), AO1-GND, AO2-GND (analog outputs), X1-COM to X4-COM (digital inputs), HDI-COM (high-speed pulse input), A+ B- (RS485 communication), Y1-COM (collector open circuit output), HDO-COM (high-speed pulse output), and K1A-K1B-K1C, K2A-K2B-K2C (electric relay terminals).

Signal Input Terminal Wiring Instruction: Analog voltage signals are susceptible to external interference. Use shielded cables, keep cable lengths under 20m, and consider adding filter wave electric capacitors or iron-oxygen magnetism where signals are seriously disturbed.

3. Operating Instructions

3.1 Operation Display Interface

The VFD features a user-friendly interface for monitoring and control. The front panel includes a display area, speed control knob, and various keys for programming and operation.

VFD front panel layout with labeled keys and display
Front panel layout with labels: Display area, Speed control knob, Displacement key, Run key, Programming Key, Increment Key, Stop/reset key, Decrement key, Confirm key, Multi-function keys. Model SU-900.

3.2 Detachable Smart Panel

The VFD is equipped with a detachable smart panel for remote operation and control. An external extension network cable is required to connect the panel remotely, allowing for flexible adjustment of working conditions.

Detachable panel connected via network cable
Detachable panel connected via network cable, showing the terminal block and the panel itself.

3.3 Key Panel Functions

KeyKey NameKey Function
PRGProgramming KeyEnter or withdraw from Level I menu.
ENTERConfirm KeyEnter menu levels, confirm parameter settings.
Increment KeyIncrease data or function code.
Decrement KeyDecrease data or function code.
Shift KeySelect display parameters, select modify bit when modifying parameters.
RUNRunning KeyUsed for running operation under keyboard control.
STOP/RESStop/Reset KeyStop running operation, reset from failure alarm status.
MF.KMultiply Functions Select KeySelect process function shift according to P7-01.

3.4 Operation Demonstration Video

Watch this video for a demonstration of the inverter's panel test, positive and negative operation, removable panel functionality, and short circuit protection test.

Demonstration of inverter functions including panel test, positive/negative operation, removable panel, and short circuit protection test.

4. Maintenance

4.1 General Care

To ensure the longevity and optimal performance of your VFD inverter, regular inspection and proper care are essential. Keep the unit clean and free from dust and debris.

4.2 Enhanced Durability Features

  • Three Anti-Paint Process: The inverter utilizes a fully automatic double-sided coating equipment with imported polyurethane cool treatment. This process improves the stability of the inverter in harsh environments, protecting against moisture, dust, and corrosion.
  • Efficient Heat Dissipation: Equipped with DC fans and an intelligent start/stop aluminum alloy radiator, the VFD achieves faster cooling speeds, ensuring stable operation even under heavy loads.
  • Industrial-Grade Components: The internal components are designed for industrial use, featuring low-loss high-frequency transformers, overload protection, and wide voltage input functions. The independent bridge wall power supply scheme includes self-check for abnormal power supply functions.
  • Reliable Welding Process: The circuit board uses SMT (Surface Mount Technology) with smooth and reliable thousand-column solder paste, ensuring the reliability and gloss of welding for long-term performance.
Internal view of VFD circuit board showing anti-EMC power supply
Internal view of the VFD circuit board, highlighting the industrial equipment anti-EMC power supply with low loss high frequency transformer and overload protection.
VFD with DC fan for efficient heat dissipation
Side view of the VFD showing the DC fan for efficient heat dissipation, ensuring quick cooling with an intelligent start and stop aluminum alloy radiator.
Internal circuit board showing welding process and components
Internal circuit board view, emphasizing the quality of the welding process and the use of well-known brand components for stability and durability.

5. Troubleshooting

The VFD inverter is equipped with various warning and protection functions. When a fault occurs, the inverter will stop output, and the display panel will show a failure code. Refer to the table below for common faults and their solutions.

5.1 Common Failure Alarms and Policies

Failure NameFailure CodeFailure ReasonTreatment Policies
Inverter unit protectionErr1Output circuit short circuit, too long motor/converter wiring, overheat module, loose internal wiring, abnormal control/drive board, abnormal mutation module.Solve outer failure, install reactor/filter, check air channel/fan, plug in wiring, seek technical support.
Accelerate over currentErr2Output circuit grounding/short circuit, incorrect control method/parameters, too short accelerate time, unsuitable V/F curve, lower voltage, starting rotating motor, sudden load during accelerating, smaller frequency converter model.Solve outer failure, process motor parameter identification, increase accelerate time, adjust V/F curve/voltage, cancel sudden load, select bigger power grade converter.
Moderate over currentErr3Output circuit grounding/short circuit, incorrect control method/parameters, too short moderate time, lower voltage, sudden load during moderating, no brake unit/resistance.Solve outer failure, process motor parameter identification, increase moderate time, adjust voltage, cancel sudden load, install brake unit/resistance.
Constant speed over currentErr4Output circuit grounding/short circuit, incorrect control method/parameters, lower voltage, sudden load during running, smaller frequency converter model.Solve outer failure, process motor parameter identification, adjust voltage, cancel sudden load, select bigger power grade converter.
Input lack phaseErr12Abnormal three-phase input power supply, abnormal drive board, abnormal lightning protection board, abnormal main control board.Check and solve existing problems in outer circuit, seek technical support.
Module overheatErr14Too high environment temperature, air channel blocked, fan damaged, module thermal resistor damaged, inverter module damaged.Reduce environment temperature, clean air channel, renew fan/resistor/module.

For a complete list of fault codes and detailed troubleshooting steps, please refer to the full PDF user manual, Chapter 6, pages 68-73.

6. Specifications

6.1 Product Parameters

Table of product parameters for SUSWE VFD inverter
Detailed product parameters including name, power specifications, input voltage, rated current, input frequency, protection level, temperature range, cooling mode, motor usage, product protection, and scope of use.
ParameterValue
NameGeneral purpose inverter
Power specifications0.75-45KW
Input Voltage220V/380V
Rated current1.5-320A
Input frequency50/60HZ
Protection levelIP20
Temperature range-20~+60°C
Cooling modeSelf-cooling fan
Use the motorSuitable for fans and pumps
Product protection6 great protections
Scope of useWoodworking machinery/food machinery/textile machinery/plastic machinery/CNC machine printing machinery/automation and other occasions requiring higher motor control

6.2 800/900 Frequency Converter Series Index

The following tables detail the specifications for single-phase and three-phase power supply models within the SU-800/900 series.

Single Phase Power Supply: 220V, 50Hz/60Hz

Frequency Converter ModePower Supply Capacity (KVA)Rated Input Current (A)Rated Output Current (A)Adapted Motor
kWHP
SU800-0R75G11.58.22.50.751
SU800-1R5G13144.11.52
SU800-2R2G14235.82.23
SU800-4R0G15.531944
SU800-5R5G18.926135.55
SU800-7R5G12135177.510

Three Phase Power Supply: 380V, 50Hz/60Hz

Frequency Converter ModePower Supply Capacity (KVA)Rated Input Current (A)Rated Output Current (A)Adapted Motor
kWHP
SU800-0R75G31.53.62.50.751
SU800-1R5G335.14.11.52
SU800-2R2G3465.82.23
SU800-4R0G36.110.5945
SU800-5R5G38.914135.57.5
SU800-7R5G31121177.510
SU900-0R75G31.53.62.50.751
SU900-1R5G335.14.11.52
SU900-2R2G3465.82.23
SU900-4R0G36.110.5945
SU900-5R5G38.914.6135.57.5
SU900-7R5G31121177.510
SU900-11R0G31726251115
SU900-15R0G32135321520
SU900-18R5G32438.53718.525
SU900-22R0G33046.5452230
SU900-30R0G34062603040
SU900-37R0G35776753750
SU900-45R0G36992914560

6.3 Certifications

The SUSWE VFD inverter is certified to meet international quality and safety standards, including CE, FC, and RoHS.

Certifications for SUSWE VFD inverter
Certifications for the VFD inverter, including FC, CE, and RoHS, ensuring compliance with relevant standards.

7. Warranty and Support

7.1 Warranty Description

The frequency converter itself is covered by an 18-month warranty from the date of manufacture (subject to the bar code on the appearance) under normal use conditions. If failure or damage occurs within this period, the manufacturer will be responsible for the warranty.

A reasonable maintenance fee will be charged for issues occurring after 18 months or under the following conditions:

  • Damage caused by the user's failure to comply with the provisions of this manual.
  • Damage caused by external factors such as fire, flood, or abnormal voltage.
  • Damage caused by applying frequency converters to abnormal functions.

Relevant service costs will be calculated according to the manufacturer's standard rates. If a contract exists, it will be handled according to the principle of contract priority.

7.2 Additional Support

For detailed parameter settings, advanced configurations, and comprehensive communication protocols, please refer to the complete user manual available as a PDF: SUSWE SU-800/900 Series VFD User Manual (PDF).

8. User Tips

  • Motor Compatibility: When selecting a VFD, ensure its power rating (kW) and voltage (e.g., 220VCA or 380VCA) match your motor's specifications. For specialized applications like motors submerged in a well, verify the VFD's environmental ratings (e.g., IP rating) and ensure it can handle the specific load characteristics.
  • Braking Resistor: For applications requiring rapid deceleration or handling high inertia loads, a braking resistor may be necessary. Consult the wiring diagrams and specifications for your specific VFD model (e.g., 18KW 380V input/output) to determine if a braking resistor is required and how to connect it to the P+ and PB terminals.