1. Introduction
The SUSWE SU700 series Variable Frequency Drive (VFD) is a high-performance inverter designed for precise control of 3-phase AC motors. It converts 380V three-phase input power into variable frequency and voltage output, enabling efficient motor speed and torque regulation. This manual provides essential information for the safe installation, operation, and maintenance of your VFD.
2. Safety Information
WARNING: Improper installation or operation can lead to serious injury or equipment damage. Read this manual thoroughly before installation and operation.
- Ensure all power is disconnected before performing any wiring or maintenance.
- Only qualified personnel should install, operate, and maintain this equipment.
- The VFD contains high voltage even after power is disconnected. Wait at least 5 minutes after power-off for capacitors to discharge before touching internal components.
- Ensure proper grounding of the VFD and the motor.
- Do not operate the VFD with damaged cables or loose connections.
- Provide adequate ventilation to prevent overheating.
3. Product Overview
3.1 Features
- Human-machine interactive button panel for easy operation.
- Detachable operation panel for remote control and flexible installation.
- Supports 380V three-phase input and output.
- Wide output frequency range: 0-600Hz.
- Multiple power ratings available from 2.2KW to 22KW.
- Compact design for space-saving installation.
3.2 Components and Naming Rules
The SU700 series VFD features a clear display and intuitive control buttons. The model naming convention (e.g., FK-700A) indicates voltage grade, power grade, and model type.


4. Specifications
The following table outlines the general specifications for the SU700 series VFD. Specific parameters may vary by model (e.g., power rating).
| Parameter | Value |
|---|---|
| Brand Name | SUSWE |
| Model Number | SU700 |
| Type | DC/AC Inverters |
| Input Voltage | Three-phase 380V |
| Output Voltage | Three-phase 380V |
| Output Frequency | 0-600HZ |
| Output Power Range | 2.2KW - 22KW (Specific models: 2.2KW, 4KW, 5.5KW, 7.5KW, 11KW, 15KW, 18.5KW, 22KW) |
| Output Current Range | 7-17A (Varies by power rating) |
| Dimensions (approx.) | 85*180*116 mm (for smaller models, larger models will vary) |
| Weight (approx.) | 1.4KG - 2KG (Varies by power rating) |
| Origin | Mainland China |
For detailed specifications of specific power ratings, please refer to the series index table below:

5. Setup
5.1 Installation
- Mount the VFD vertically on a stable, non-flammable surface.
- Ensure sufficient clearance around the VFD for proper ventilation (at least 10cm on all sides).
- Avoid installing in direct sunlight, high humidity, dusty environments, or near corrosive gases.
- Operating temperature range: -10°C to 40°C.
5.2 Wiring
All wiring must be performed by a qualified electrician in accordance with local and national electrical codes. Ensure power is OFF before wiring.
5.2.1 Power Wiring
Connect the three-phase 380V power input to the R, S, T terminals. Connect the motor to the U, V, W terminals. Ensure proper grounding.

5.2.2 Control Circuit Wiring
The control circuit allows for external control signals, analog inputs, and communication. Refer to the diagram for connections of multifunctional digital inputs (X1-X4), analog inputs (AI1, AI2), analog output (AO1), open collector output (Y1), high-speed pulse output (HD0), and RS485 communication (A+, B-).

6. Operating Instructions
6.1 Button Panel Functions
The VFD features a human-machine interactive button panel for control and monitoring:
- Display Screen: Shows frequency, current, voltage, and other operational parameters.
- Knob: Used for adjusting frequency and parameter values.
- PRG (Programming Key): Enters/exits programming mode.
- MFK (Multiple Use Key): Function varies based on context.
- Up/Down Arrows (Incremental/Decrement Keys): Adjust parameter values or navigate menus.
- ENTER Key: Confirms selections or parameter changes.
- RUN Key (Green): Starts motor operation.
- STOP Key (Red): Stops motor operation.
- Shift Key: Moves cursor during parameter editing.
- Operation Indicator: Lights up during operation.
- Forward and Reverse Indicator: Shows motor direction.
- Tuning / Fault Indicator: Indicates tuning status or fault conditions.
6.2 Basic Operation
- Power On: After ensuring all wiring is correct and secure, apply power to the VFD. The display will light up.
- Set Frequency: Use the knob or the Up/Down arrow keys to set the desired output frequency.
- Start Motor: Press the RUN key. The motor will start accelerating to the set frequency.
- Stop Motor: Press the STOP key. The motor will decelerate and stop.
- Parameter Programming: Press the PRG key to enter programming mode. Use arrow keys to navigate, the knob to change values, and ENTER to confirm.
6.3 Detachable Operation Panel
The VFD features a detachable operation panel for convenience. To remove the panel, gently press inward on the side release mechanism and pull the panel away. It can then be connected remotely using an appropriate extension cable.

7. Maintenance
- Regular Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth. Do not use liquids or solvents.
- Ventilation Check: Ensure cooling fans are operating correctly and air vents are not obstructed.
- Connection Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Environmental Conditions: Monitor the operating environment to ensure it remains within specified temperature and humidity limits.
- Capacitor Discharge: Always wait for the 'DANGER' light to extinguish (approx. 5 minutes) after power-off before performing any internal maintenance.
8. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| VFD does not power on | No input power; Blown fuse; Loose wiring | Check power supply; Inspect fuses; Verify all power connections |
| Motor does not run | Incorrect wiring; Parameter settings; Emergency stop active | Check motor and control wiring; Verify run command and frequency settings; Reset emergency stop |
| Overcurrent fault | Motor overload; Short circuit; Acceleration time too short | Reduce motor load; Check motor and output wiring for shorts; Increase acceleration time parameter |
| Overvoltage fault | Input voltage too high; Deceleration time too short | Check input voltage; Increase deceleration time parameter; Consider braking resistor if regenerative load |
| Overheat fault | Insufficient ventilation; Ambient temperature too high; Fan failure | Ensure proper airflow; Reduce ambient temperature; Check cooling fan operation |
9. Warranty and Support
For any questions, technical assistance, or warranty claims, please contact the seller or manufacturer directly. Provide your product model number and purchase details for efficient support.
We guarantee the quality of our products. Each item is carefully checked before delivery. If you are satisfied with our products and service, please kindly leave positive feedback. If you have any problems after receiving the goods, we will help you solve the problem.