1. Overview
This manual provides essential information for the specification, performance, and operation methods of the LS Electric XGT Series Programmable Logic Controllers (PLCs), including models XGP-ACF1, XGP-ACF2, and XGP-AC23. These devices are designed for industrial automation applications, offering reliable control and processing capabilities.


The XGK system offers several key features:
- Compact Size: Designed for installation in small spaces.
- High-Speed Processing: Efficient execution of sequence instructions, MOV instructions, and floating-point arithmetic operations.
- Improved Data Transfer: Enhanced data transfer speed between modules through the base unit.
- Analog Data Convenience: Simplified handling of analog data with program setting methods.
- Flexible System Configuration: Various convenient functions are provided, including filter value adjustment of input modules, output hold at emergency time, varistor built-in relay output modules, extended base length up to 15m, RN contact provision, and self-diagnosis for maintenance.

Understanding PLC terminology is crucial for proper operation:

- Sink Input: Current flows from the switch to the PLC input terminal when an input signal turns on.
- Source Input: Current flows from the PLC input terminal to the switch after an input signal turns on.
- Sink Output: Current flows from the load to the output terminal and the PLC output turns on.
- Source Output: Current flows from the output terminal to the load and the PLC output turns on.
2. Setup
The XGT series PLCs are designed for flexible system configuration. A typical setup involves connecting the main base and expanded base via a cable, with I/O numbers assigned based on the module type and installation slot.

Key components in a system configuration include:
- Battery
- CPU Module
- RS-232C / USB Cable (for connection to XG5000 software)
- Main Base (e.g., XGB-M04A)
- Extension Cable
- Extension Base
- Power Module (e.g., XGP-ACF1, XGP-ACF2, XGP-AC23, XGK-DC42)
- Input/Output Module
- Special Module
- Communication Module
- Terminating Resistor (XGT-TERA)
USB Cable Recommendations:
- Use a shielded USB-301A cable from the company, shorter than 3m, to avoid disconnection with XG5000.
- When connecting to a PC in a noisy environment, use a USB Hub.

The basic system configuration involves connecting the main base and expanded base via a cable. The number of stages of the expanded base is limited by the CPU type. I/O numbers are allocated based on module installation and type. For a one-base system, 16 slots are allocated, with the first slot becoming P0040. Specific points can be assigned by I/O parameter, or automatically assigned according to the actual module installed.
3. Operating
The XGT Series PLCs are designed for efficient and reliable operation in various industrial control scenarios. Programming is typically done using dedicated software (e.g., XG5000) which allows users to define logic, configure I/O, and monitor system status.
The CPU modules (e.g., XGK-CPUUN, XGK-CPUH, XGK-CPUS, XGK-CPUE) offer varying processing speeds and memory capacities to suit different application requirements. For example, the XGK-CPUUN has a sequence instruction speed of 8.5 ns and MOV instruction speed of 25.5 ns, while the XGK-CPUU has 26 ns and 84 ns respectively.
The system supports various I/O modules, including digital input, digital output, and digital input/output modules, allowing for flexible connection to sensors, actuators, and other devices. The power supply modules provide stable DC5V power to the system components.
4. Maintenance
Regular maintenance is crucial for ensuring the longevity and reliable operation of your PLC system. This includes:
- Environmental Control: Ensure the operating environment is within specified temperature and humidity ranges, and free from excessive dust, vibration, and electromagnetic interference.
- Connection Checks: Periodically inspect all wiring and connections for tightness and signs of corrosion or damage.
- Cleaning: Keep the PLC unit and surrounding area clean. Use a soft, dry cloth to wipe down surfaces. Avoid using harsh chemicals or abrasive materials.
- Battery Replacement: The PLC contains a battery (XGT-BAT) for retaining data. Refer to the full user manual for specific instructions on checking battery status and replacement procedures to prevent data loss.
- Firmware Updates: Check the manufacturer's website for any available firmware updates that may improve performance or address known issues.
5. Troubleshooting
If you encounter issues with your PLC, consider the following general troubleshooting steps:
- Power Issues: Verify that the power supply is correctly connected and providing the specified voltage. Check power indicators on the PLC.
- Connection Problems: Ensure all modules are securely seated and all cables (I/O, communication, power) are properly connected.
- Error Indicators: Observe any error LEDs or messages on the PLC. Consult the detailed user manual for specific error code interpretations.
- Software Connectivity: If unable to connect via programming software, check USB/RS-232C cable integrity and driver installation.
- I/O Malfunctions: Test individual input and output devices to ensure they are functioning correctly. Verify wiring to the PLC I/O modules.
- Program Logic: Review your PLC program for any logical errors or incorrect configurations.
For complex issues, refer to the comprehensive troubleshooting section in the full user manual or contact technical support.
6. Specifications
The LS Electric XGT Series Programmable Logic Controllers offer robust performance for industrial applications. Below are key specifications for the XGP-ACF1, XGP-ACF2, and XGP-AC23 models, along with general system characteristics.
General Product Specifications
| Attribute | Value |
|---|---|
| Model Numbers | XGP-ACF1, XGP-ACF2, XGP-AC23 |
| Type | DC/AC Inverters |
| Output Current | 1.1 |
| Output Frequency | 0-400HZ |
| Output Power | 51 - 100W |
| Output Type | Triple |
| Weight | 1.8 kg |
| Size (L*W*H) | 21*11*15 cm |
| Certification | CE |
| Origin | Mainland China |
| is_customized | Yes |
Power Supply Module Specifications

| Product | Type | Content |
|---|---|---|
| Power supply module | XGP-ACF1 | AC100V / 240V Input, DC5V / 3A, DC24V / 0.6A |
| XGP-ACF2 | AC100V / 240V Input, DC5V / 6A | |
| XGP-AC23 | AC200V / 240V Input, DC5V / 8.5A | |
| XGK-DC42 | DC24V / 0V Input, DC5V / 6A | |
| Extension cable | XGC-E041 | Length: 0.4 m |
| XGC-E061 | Length: 0.6 m | |
| XGC-E121 | Length: 1.2 m | |
| XGC-E301 | Length: 3.0 m | |
| XGC-E501 | Length: 5.0 m | |
| XGC-E102 | Length: 10 m | |
| Terminating resistor | XGT-TERA | Must use terminating resistor when connecting extension base |
| Dust proof module | XGT-DMMA | Dust protection module for unused slot |
| Battery | XGT-BAT | Battery for XGT(DC 3.0V/1,800 mAh) |
Note: Total extension distance should not exceed 15m.
CPU Module and I/O Specifications

| Product | Type | Content | Remarks |
|---|---|---|---|
| CPU Module | XGK-CPUUN | Standard type CPU module (Max I/O point: 1,536 points) | 16kstep |
| XGK-CPUSN | Standard type CPU module (Max I/O point: 3,072 points) | 32kstep | |
| XGK-CPUUA | High speed type CPU module (Max I/O point: 3,072 points) | 32kstep | |
| XGK-CPUH | High speed type CPU module (Max I/O point: 6,144 points) | 64kstep | |
| XGK-CPUN | High speed type CPU module (Max I/O point: 6,144 points) | 64kstep | |
| XGK-CPUUN | High speed type CPU module (Max I/O point: 6,144 points) | 256kstep | |
| Digital input module | XGI-D21A | DC24V Input, 8 point (Current source / sink input) | - |
| XGI-D21D | DC24V Diagnosis Input, 8 point (Current source / sink input) | - | |
| XGI-D22A | DC24V Input, 16 point (Current source / sink input) | - | |
| XGI-D24A | DC24V Input, 32 point (Current source / sink input) | - | |
| XGI-D28A | DC24V Input, 64 point (Current source / sink input) | - | |
| XGI-D22B | DC24V Input, 16 point (Current source input) | - | |
| Digital output module | XGQ-RY1A | Relay output, 8 point (for 2A, single COM) | - |
| XGQ-RY1D | Diagnostic Relay output, 8 point (for 2A) | - | |
| XGQ-RY2A | Relay output, 16 point (for 2A) | - |
7. User Tips
To maximize the performance and lifespan of your LS Electric PLC, consider these user tips:
- Proper Grounding: Always ensure proper grounding of the PLC system to prevent electrical noise and ensure stable operation.
- Software Compatibility: Use the recommended programming software (e.g., XG5000) and ensure it is compatible with your specific PLC model and operating system.
- Backup Programs: Regularly back up your PLC programs. This is crucial for quick recovery in case of system failure or accidental program deletion.
- Environmental Considerations: Protect the PLC from extreme temperatures, humidity, and corrosive environments. Install it in a well-ventilated enclosure if necessary.
- Cable Management: Organize and label all wiring clearly. This simplifies troubleshooting and maintenance.
- Read the Full Manual: For detailed wiring diagrams, specific error codes, and advanced programming techniques, always refer to the complete user manual provided by LS Electric.
8. Warranty & Support
For warranty information, technical support, or service inquiries regarding your LS Electric XGP-ACF1, XGP-ACF2, or XGP-AC23 Programmable Logic Controller, please contact the manufacturer or your authorized distributor. Ensure you have your product model number and serial number available when seeking support.
LS Electric provides comprehensive support resources, including detailed documentation and technical assistance, to ensure optimal performance and reliability of their products.