1. Introduction
1.1 Product Profile
The XP200 digital AC servo driver is a leading general AC servo drive product. This series adopts advanced full-digital control and AC motor vector control theory, offering excellent performance and high reliability. These products are widely used in servo shaft drives for food processing, packaging machinery, textile machinery, and other related automatic industrial machinery.
Product Features:
- High-performance DSC chip and large-scale programmable logic control chip for excellent control performance.
- Small and exquisite design of XP200 saves installation space.
- New industrial-grade IPM module with strong overload drive capability.
- Integrated speed control, position control, and torque control.
- Compatible with various types of permanent magnet synchronous servo motors.
- Comprehensive fault protection and status monitoring functions.
- Excellent low-speed torque characteristics and industry-leading dynamic acceleration and deceleration performance.
2. Product Overview
The HLTNC 110SG M06030 AC Servo Motor Kit includes the servo motor, XP200 servo driver, and necessary cables.
2.1 Set Content
- Power line code line (3M)
- EC-XP200-30PL Servo Driver
- EC-F4CC180V-M2XM*A Servo Motor
3. Specifications
3.1 General Product Properties
| Attribute | Value |
|---|---|
| Brand Name | HLTNC |
| Hltnc Model | 110SG-M06030 |
| Model Number | EC-F4CC180V |
| Type | Servo Motor |
| Phase | Three-phase |
| AC Voltage | 208-230 / 240 V |
| Output Voltage | 1.8kw |
| Rated Current | 6A |
| Rated Torque | 6Nm |
| Fated Speed | 3000rpm |
| Encoder | 2500line Photoelectric |
| Driver Model | EC-XP200-30PL |
| Standard Cable Length | 3meter |
| Protect Feature | Totally Enclosed |
| Efficiency | IE 2 |
| Certification | CCC, CE, NONE |
| Analog Voltage Control | Support |
| RS485 | Support |
| Does it include wireless functionality? | No |
| Does it include a Battery? | No |
| High-concerned chemical | None |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc |
3.2 Driver Model Specification (XP200)
The XP200 model naming convention is as follows:
- Driver Series: XP200-Servo Driver Series
- Voltage Rating: L: 220V, H: 380V
- IPM Module Capacity: 20-20A, 30-30A
- Communication type: P: 485 Communication Mode, C: CAN Bus, E: EtherCAT Bus
- Encoder Communication Mode: None: Parallel communication 2500 lines, R: Serial communication with 17/23 bits.
3.3 Servo Motor Product Parameters
| Parameter | Value |
|---|---|
| Model number | EC-F4CC180V-M2XM*A |
| Rated current (A) | 6 |
| Rated rev (RPM) | 3000 |
| Rated power (KW) | 1.8 |
| Rated torque (Nm) | 6 |
| Rated voltage (V) | 220 |
3.4 Drive Specifications and Performance Parameters
| Parameter | Description |
|---|---|
| Input Power Supply | Single-phase/three-phase 220VAC -15%~+10% 50/60Hz |
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -40°C ~ 50°C |
| Operating Humidity | 40%~80% (no condensation) |
| Storage Humidity | Lower than 93% (without moisture condensation) |
| Atmospheric Pressure | 86kPa ~ 106 kPa |
| Protection Grade | IP20 |
| Control Mode | Position, Speed, Torque, Position/Speed, Speed/Torque, Position/Torque |
| Digital Input | 8 programmable input terminals (photoelectric isolation) |
| Digital Output | 6 programmable output terminals (photoelectric isolation) |
| Encoder Signal Output Type | A, B, Z differential output, Z signal open collector output |
| Input Frequency | Differential inputs: ≤500kHz (kpps); Single-ended input: ≤200kHz (kpps) |
| Position Command Mode | Pulse + symbol; Forward/reverse pulse; Orthogonal pulse |
| Electronic Gear Ratio | 1~32767/1~32767 |
| Simulation Command Input | ±10VDC, input impedance 10KΩ |
| Speed Command Acceleration/Deceleration | Parameter setting P-060/P-061 |
| Speed Command Source | Analog quantity, internal speed command |
| Torque Command Input | -10V ~ +10V, input impedance 10KΩ |
| Torque Limitation | Parameter setting P-065/P-066 |
| Torque Command Source | Analog quantity, internal torque command |
| Monitoring Function | Rotate speed, current position, position deviation, motor torque, motor current, command pulse frequency, etc. |
| Protection Functions | Over-speed, over-voltage, over-current, overload, brake abnormality, encoder abnormality, position overshoot, command overclocking, etc. |
| Velocity Frequency Response | ≥800Hz |
| Velocity Fluctuation Rate | <±0.03% (load 0~100%); <±0.02% (power -15% ~ +10%) |
4. Setup
4.1 Wiring Instructions
4.1.1 Front Panel Terminal Wiring Diagram
Important Wiring Notes:
- Motor power lines U, V, W, PE should be connected to the corresponding terminals separately. Do not misconnect.
- Energy consumption brake resistance should be connected between P and BK terminals.
- The XP200 series power supply is three-phase AC220V or single-phase 220V.
- For single-phase power supply, connect the R and T terminals.
- The main power supply of the driver is connected to the R, S, and T terminals.
4.1.2 Brake Resistance Specification
Standard 220V servo models do not contain built-in resistance. An external brake resistor must be connected, except for custom models.
| Driver Model | Recommended Configuration (Light Load Type) | Recommended Configuration (Overload Type) |
|---|---|---|
| XP200-20PL | 10Ω, power > 60W (Starting/stopping not frequent) | ≥47Ω, power > 500W (Starting/stopping frequent) |
| XP200-30PL | 47Ω, power > 100W (Starting/stopping not frequent) | ≥47Ω, power > 500W (Starting/stopping frequent) |
4.1.3 Definition Diagram of Control Port CN2 and Encoder Port CN3
Special Attention for Pulse Command Signal:
- If the pulse command signal is powered by 24V: Connect the 35-pin of CN2 to 24V. Connect the negative terminal of the pulse signal to the 43-pin of CN2. Connect the negative terminal of the direction signal to the 39-pin of CN2.
- If the pulse command signal is powered by 5V: Do not connect the 35-pin of CN2. Instead, connect PULSE+ to the 41-pin of CN2, PULSE- to the 43-pin of CN2, SIGN+ to the 37-pin of CN2, and SIGN- to the 39-pin of CN2.
4.1.4 Communication Port CN2 Connection Diagram
The digital input interface circuit can be controlled by switches, relays, open-collector transistors, photocouplers, etc. The external voltage range is DC12V to 24V.
Digital Input Interface (C1)
The output circuit adopts Darlington photocouplers and can be connected to relays and photocouplers. Precautions:
- The power supply is user-provided. Reverse connection will damage the driver.
- Maximum external power supply voltage: 25V.
- Maximum output current: 50mA. Total current of three channels should not exceed 100mA.
- For inductive loads (e.g., relays), a diode must be connected in parallel. Reverse polarity will damage the driver.
- A voltage drop of about 1V occurs when conducting, which may not meet TTL low-level requirements. Cannot be directly connected to TTL circuits.
5. Operation
5.1 Panel Operation
The XP200 series panel features 5 LED digital tube displays and 4 keys (▲, ▼, ◀, ▶) plus an Enter key, along with POW and RUN LEDs. These are used for displaying and setting system parameters.
5.1.1 Symbols and Functions
| Symbol | Name | Function |
|---|---|---|
| POW | Power indicator | Lit: Main power source power-on; Off: Main power source power-off. |
| RUN | Running light | Lit: Motor in power-on operation; Off: Motor is power-off. |
| ▲ | Increase key | Increase sequence number or numerical value; long press for repetitive effect. |
| ▼ | Decrease key | Decrease sequence number or numerical value; long press for repetitive effect. |
| ◀ | Exit key | Menu exits; operation cancelled. |
| Enter | Confirmation key | Menu entry; parameter modification confirmation or operation confirmation. |
| S | Shift key | Quick modification of parameter number or parameter value (for T3L only). |
5.1.2 Main Menu Navigation
The main menu has four modes of operation. Use the ▲ and ▼ keys to change the way. Press Enter to enter the second floor for specific operations. Press the ◀ key to return to the main menu from the second floor.
- Status (d-): Monitor various operating parameters.
- Parameter (P-): Set and modify system parameters.
- Auxiliary (A-): Access auxiliary functions.
5.2 Parameter Setting and Function Debugging
5.2.1 Initial Test Run
When using the drive unit for the first time, it is recommended to perform a test run (keyboard speed regulation or JOG Running) without connecting the load. Ensure the drive unit and servo motor work properly after handling and installation, and that the default parameters of the drive unit adapter are valid.
After the drive unit and motor are working properly, connect the CN1 control terminal without load, and use with the CNC device of the upper computer to debug and run in speed, position, or other modes as needed.
Once signal connection, parameter setting, and motor operation are debugged normally, connect the load and run with load.
5.2.2 Set Motor Code
- Modify the operation password (parameter P-000) to 385.
- Modify the motor Code (parameter P-002) according to the motor model. Refer to the Motor Adaptation Table in Section 3.4.
- Enter parameter management and perform the reset default values action.
Special attention: The operation to restore default values must be carried out when the driver is not enabled, otherwise an Error will be displayed.
After successful panel display operation, turn off the power supply, wait for the drive panel to extinguish, then turn on the power supply again to proceed with the next operation (keyboard speed test running or JOG running).
5.2.3 Trial Run (Keyboard Speed Regulation & JOG Spot Test)
After confirming no alarms or exceptions, operate as follows:
- Keyboard Speed Regulation: The panel displays 'r.' (r/min). Use ▲/▼ keys to change speed. Positive numbers indicate forward rotation (CCW), negative numbers indicate reverse rotation (CW). Minimum speed is 0.1 r/min. If the motor runs normally, you can enter spindle control parameter settings.
- JOG Spot Test: Turn on main circuit power. Set P-098 to 1 (servo enable SON). The RUN indicator will light. In the auxiliary function menu 'A-', select 'A-JOG' and press Enter. The jog prompt 'J' will appear. Press and hold ▲ for JOG speed (CCW), release to stop. Press and hold ▼ for JOG speed reverse (CW), release to stop. JOG speed is set by parameter P-076 (default 100r/min).
5.2.4 Coordinate with PC Controller
The servo driver operates in three modes: Position, Speed, and Torque mode.
- Position Control Mode: For precise positioning (e.g., CNC machine tools). Uses pulse commands (PULS+, PULS-, SIGN+, SIGN-).
- Speed Control Mode: For precise speed control (e.g., knitting machines). Can form closed-loop control with upper device.
- Torque Control Mode: For printing, winding, injection molding machines. Motor output torque is proportional to input command.
Refer to the full manual PDF for detailed parameter settings for each control mode: User manual (PDF).
6. Maintenance
6.1 Electromagnetic Brake
The electromagnetic brake (holding brake and power loss brake) is used to lock vertical or inclined worktables to prevent falling after servo power loss. A motor with a brake is required for this function. Brakes are for holding, not for slowing down or stopping movement.
6.1.1 Electromagnetic Brake Related Parameters
| Parameter | Name | Scope | Default Values | Unit | Applicable |
|---|---|---|---|---|---|
| P165 | Motor static speed detection point | 0~1000 | 5 | r/min | ALL |
| P166 | Delay time of electromagnetic brake when motor is stationary | 0~2000 | 200 | ms | ALL |
| P167 | Waiting time of electromagnetic brake when motor is running | 0~2000 | 500 | ms | ALL |
| P168 | Operating speed of electromagnetic brake when motor is running | 0~3000 | 100 | r/min | ALL |
| P169 | Delay time for release of electromagnetic brake | 0~3000 | 200 | ms | ALL |
6.1.2 Use of Electromagnetic Brake
The brake wiring diagram shows the brake release signal BRK of the driver connected to the relay coil, and the relay contact connected to the brake power supply. The brake power supply is user-provided and must have sufficient capacity. It is recommended to install a surge absorber to suppress surge voltage. Diodes can also be used as surge absorbers. Note that there may be a slight braking delay.
When the motor is stopped and stationary (speed less than P-165), and the servo is turned OFF, the motor remains energized to maintain position. The brake is released. After a stabilization period (P-166), motor power is removed.
When the motor is running (speed higher than P-165) and servo is OFF, motor current is cut off, and the brake remains released. After a delay, the brake is applied. This reduces motor speed from high to low before mechanical brake actuation, preventing damage. The delay time is determined by P-167 or motor speed deceleration to P-168, whichever is minimum.
P-169 defines the delay time from motor current opening to electromagnetic brake release (DO output terminal BRK ON) when the system transitions from non-enabled to enabled state.
6.2 General Care
Regularly inspect all connections for tightness and signs of wear. Keep the driver and motor free from dust and debris to ensure proper cooling and operation. Avoid exposing the unit to excessive moisture or extreme temperatures.
7. Troubleshooting
7.1 Alarm Codes
The XP200 driver has comprehensive fault protection. When an alarm occurs, the driver will display an alarm code. Refer to the table below for common alarm codes and their meanings.
| Alarm Code | Alarm Name | Alarm Content | Alarm Clearable |
|---|---|---|---|
| Err-- | No alarm | Working normally | |
| Err 1 | Speeding | Motor speed exceeds maximum limit | YES |
| Err 2 | Power main circuit over voltage | Main circuit power supply voltage exceeds the specified maximum value | NO |
| Err 3 | Power main circuit under voltage | Main circuit power supply voltage is lower than the specified minimum value | NO |
| Err 4 | Position following-deviation too large | The value of the position deviation counter exceeds the set value | YES |
| Err 5 | Position command over clocking | Position command frequency exceeds the highest frequency | YES |
| Err 6 | Motor stall | Motor shaft is blocked, or wiring is incorrect, or pole pair setting is incorrect, or encoder line number is incorrect. | YES |
| Err 8 | Speed response failure | Excessive spindle load makes the speed deviation too large, or pole pair setting is incorrect, or encoder line number is incorrect. | YES |
| Err 9 | Incremental encoder AB signal error | Motor encoder AB signal has interference or disconnection | NO |
| Err11 | IPM module over current | Main circuit IPM (inverter) module over current or over heat. | NO |
| Err12 | Over current | Servo driver instantaneous current is too large. | NO |
| Err13 | Over load | Motor average load current is too large. | NO |
| Err14 | Brake peak power overload | Brake instantaneous load is too large. | NO |
| Err16 | Motor thermal overload | Motor heating value exceeds the set value (I²t detection). | NO |
| Err17 | Brake average power overload | Brake long-term average load is too large. | NO |
| Err18 | Power module overload | Power module output average load is too large. | NO |
| Err20 | EEPROM error | EEPROM read and write error. | NO |
| Err21 | Logic circuit error | Processor peripheral logic circuit error. | NO |
| Err23 | AD conversion reference voltage error | AD sampling circuit voltage reference is not a standard value. | NO |
| Err24 | AD conversion channel is asymmetrical or zero drift too large | AD sampling amplification conditioning circuit is abnormal. | NO |
| Err25 | Motor code error | Motor code setting is not suitable. | NO |
| Err29 | User torque overload alarm | Motor load exceeds user-set value and duration. | YES |
| Err30 | Encoder Z signal loss | Encoder Z signal does not appear. | NO |
| Err31 | Encoder Z signal detection is abnormal | Encoder Z signal has interference or signal instability. | NO |
| Err32 | Encoder UVW signal illegal coding | The motor encoder UVW signal is missing, and the Z signal can be manually turned off to cancel the alarm. | YES |
| Err34 | Spindle orientation failure | Spindle orientation function is running incorrectly. | YES |
| Err35 | Spindle encoder (second encoder) error | Spindle encoder AB polarity error. | NO |
| Err36 | Spindle encoder (second encoder) line is broken | Spindle encoder line is broken or there is interference. | NO |
7.2 Alarm Cleanup Method
When a fault alarm occurs, after troubleshooting the cause, the alarm can be cleared via the drive operating panel while power is still on. The specific method is:
Without an active alarm, set parameter P-119 to 4. Then, follow the steps on the panel to clear the history alarm code. Note: Some hardware failure alarms cannot be cleared and require consultation with technicians.
7.3 Common Problems and Countermeasures
- Error restoring default parameters:
- Confirm operation password (P-000) is set correctly.
- Default restoration must be done when the driver is not enabled.
- Upper computer enabled, but driver's green RUN light is off:
- Check R/S/T power supply voltage.
- Check CN1 interface 31 feet for +24V.
- Check if SON signal is connected to 0V at pin 16 of CN1 interface.
- If the RUN light remains off, try using the internal enable (P098 set to 1).
- "Err-9/Err-10/Err-30/Err-31/Err-32/Err-33" fault alarm (Encoder issues):
- Check encoder or encoder connection cable.
- Ensure both ends of shielding layer are well grounded and free from water/impurities.
- Verify connecting line length to prevent 5V encoder power supply attenuation.
- Isolate from strong magnetic/electric interference.
- Noise or vibration (high frequency) during servo motor operation:
- Increase filter coefficients P-007 and P-019 by 5 per adjustment.
- If not effective, reduce speed loop proportional gain and position loop proportional gain (P-005 and P-009) by 5 per adjustment.
- Check for interference in encoder connection line and shielding layer grounding.
- Jitter (low frequency) in servo motor operation:
- Verify load and inertia are within allowable range (load torque > 3 times, inertia > 5 times may require larger motor).
- Adjust proportional gain P-005 of the speed ring by 5 per adjustment.
- If not effective, decrease filter coefficient P-007/P-019 by 5 per adjustment.
- If not effective, reduce position loop gain P-009 by 5 per adjustment.
- Check for interference in encoder/command connection lines and shielding layer grounding.
- Driver has "Err-2" or "Err-11" alarm:
- If alarm on power-up, hardware circuit failure.
- If alarm during frequent acceleration/deceleration of large inertia, check current (d-I, d-pl). Reduce inertia acceleration (increase P-060, P-061) to keep current within range.
- "Err-5/Err-12" appears when servo motor starts:
- Err-5: Pulse command frequency too fast. Increase acceleration/deceleration time or position command smoothing time P-040 by 10 per adjustment.
- If measures fail, set P-116 to 32 to shield "Err-5" alarm (power cycle required).
- Err-12 (overcurrent): Motor overloaded during startup. Check driver type/damage.
- "Err-4" appears during servo motor operation:
- If low-speed normal, high-speed Err-4: Check P-075 (max rotation speed limit). Adjust P-009 (position loop gain) or P-080 (position overshoot detection range).
- If only position command given, Err-4 appears: Check if motor is locked/damaged, or if strong current circuit is damaged.
- If Err-4 during rapid acceleration: Driver/motor selection too small.
- If occasional Err-4: Check encoder/command connection line interference and shielding layer grounding.
- Driver running normally, but upper computer has "too large position tracking error":
- Set P-080 (actuator position overrun detection range) to a value smaller than the detection threshold. Observe if "Err-4" appears.
- If no "Err-4" in driver, interference in encoder signal to upper computer. Check connection line welding and shielding layer grounding.
- If "Err-4" in actuator: Response problem of actuator/motor. Confirm driver/motor integrity. Adjust P-009/P-005 (position/speed ring gain).
- If measures fail, consider larger driver/motors.
8. User Tips
No specific user tips were available from reviews or Q&A for this product at this time.
9. Warranty & Support
For warranty information and technical support, please contact the seller directly through the platform where the product was purchased. Ensure to provide your order details and product model number for efficient assistance.
You can also refer to the comprehensive user manual PDF for more detailed instructions and diagrams: User manual (PDF).