JIKONG JK-PB2A16S20P

Contents

JIKONG BMS V19 JK-PB2A16S20P User Manual

Lithium Battery Active Balance Protection Board

1. Introduction

The JIKONG BMS V19 JK-PB2A16S20P is an intelligent Battery Management System designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge/over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring. This BMS is suitable for LiFePo4, ternary Li-ion, and LTO battery types.

It utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a maximum continuous 2A balance current. This high-current active equalization technology ensures battery consistency, improves cruising range, and extends battery life. The system supports mobile APP (Android and iOS) and PC software for real-time monitoring and parameter adjustment.

JIKONG BMS V19 JK-PB2A16S20P main product image showing the BMS board, interface board, and key features.
Figure 1: JIKONG BMS V19 JK-PB2A16S20P Overview
Structural block diagram of the JIKONG BMS, illustrating internal components and connections.
Figure 2: Structural Block Diagram

2. Key Features

  • Active Balance: Real-time energy transfer equalization with supercapacitor as the medium, ensuring battery consistency and prolonging life.
  • High Balancing Current: Achieves 2A continuous balanced current.
  • Wide Voltage Range: Single cell voltage range 1V~5V, equalization accuracy ±5mV.
  • Multi-Battery Type Support: Compatible with LiFePo4, ternary Li-ion, and LTO batteries.
  • Comprehensive Protection: Overcharge, over-discharge, overcurrent, over-temperature, low-temperature, and short-circuit protection.
  • Communication Interfaces: Bluetooth, RS485, CAN, UART, RS232.
  • Monitoring & Control: Mobile APP (Android/iOS/HarmonyOS) and PC software for real-time status viewing and parameter adjustment.
  • Display Interface: Reserved interface for optional display screen.
  • Heating Function: Standard heating function for low-temperature environments.
  • Dry Contact Function: Two dry contacts for external alarm/fan control.
  • Charge Current Limiting: Limits charging current to protect the battery.
  • Patented Parallel Protection Technology: Integrated 10A current limiting module for safe parallel connection of multiple battery packs.
Image highlighting key features like intelligent communication, safely expanding battery capacity, high efficiency balance, and reverse polarity protection.
Figure 3: Key Features of JIKONG Home Energy Storage BMS
Diagram showing four communication modes/mainstream interfaces: CAN, RS485, UART, RS232, Parallel Module, Interface Board, Active Equalizer, NTC.
Figure 4: Communication Modes and Interfaces

3. Specifications

3.1. General Parameters

Parameter Value Unit
Supply Voltage20-70V
Standby Power Consumption12mW
Operating Power Consumption1100mW
Operating Temperature-30 to 70°C
Max Number of Collection Strings16S
Max Balancing Current2A
Max Charging Current (JK-PB2A16S-20P)200A
Max Discharge Current (JK-PB2A16S-20P)200A
Max Instantaneous Current (JK-PB2A16S-20P)400A
Max Internal Loop Resistance (20P)0.35mΩ
Protective Plate Size300*100*18mm
Finished Weight1000g
Table of JIKONG Product Specifications including technical index, number of battery strings, balance method, balance current, continuous discharge current, maximum discharge current, over charge protection current, wiring output, single cell voltage range, voltage acquisition accuracy, various protection voltages and delays, temperature protection, short circuit protection, coulomb counter, Bluetooth function, parallel charging current limiting, address dial switch, and DRY contact.
Figure 5: Detailed Product Specifications Table

3.2. Default Parameters (JK-PB2A16S20P)

Parameter Li-Ion LiFePo4 LTO Unit
Balancing Initial Voltage332V
Maximum Balancing Current222A
Unit Overcharge Voltage4.23.62.7V
Single Overcharge Protection Recovery4.173.542.64V
Monomer Undervoltage Protection2.822.61.8V
Single Undervoltage Protection Recovery2.852.651.85V
Automatic Shutdown Voltage2.82.51.7V
SOC-0% Voltage2.92.61.85V
SOC-100% Voltage4.183.52.65V
Trigger Balancing Differential Pressure0.010.010.01V
Charging Overcurrent Protection Delay333S
Charging Overcurrent Protection Release Time606060S
Discharge Overcurrent Protection Delay300300300S
Discharge Overcurrent Protection Release Time606060S
Short-circuit Protection Delay150015001500µS
Short-circuit Protection Release Time606060S
Charging Overtemperature Protection Temperature707070°C
Charging Overtemperature Restore Temperature606060°C
Discharge Overtemperature Protection Temperature707070°C
Discharge Overtemperature Recovery Temperature606060°C
Charging Low Temperature Protection Temperature-20-20-20°C
Charging Low Temperature Restore Temperature-10-10-10°C
MOS Overtemperature Protection Temperature100100100°C
MOS Overtemperature Protection Recovery Temperature808080°C
Device Address000/
Discharge Precharge Time000S
Diagram showing the dimensions of the JIKONG BMS protection board, including length, width, and height measurements.
Figure 6: Product Dimensions

4. Packing List

The package for the JIKONG BMS V19 JK-PB2A16S20P typically includes the following items:

  • BMS x 1
  • Interface board x 1
  • Adapter cable B x 1 (long 30cm)
  • Adapter cable A x 1 (long 30cm)
  • R545 Network cable x 1 (long 40cm)
  • Sampling line A x 2 (long 90cm)
  • Sampling line B x 1 (long 90cm)
  • Switch x 1 (long 50cm)
  • Sampling line C x 1 (long 90cm)
  • Adapter cable C x 1 (long 30cm)
  • Heating Adapter cable x 1 (long 15cm)
  • Adapter x 1
Image showing the packing list components: BMS, interface board, various adapter cables, network cable, sampling lines, switch, and an adapter.
Figure 7: Packing List Contents

5. Installation and Wiring

5.1. Unpacking and Inspection

Handle the packaging and protection board gently. Before unpacking, inspect the package for any signs of impact or damage. Ensure all components listed in the packing list are present and undamaged.

5.2. Wiring Instructions

The JIKONG BMS V19 JK-PB2A16S20P is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure all cables are connected correctly before powering on the BMS.

  1. Connect all the cables to their respective ports.
  2. Insert the interface cable into the BMS.
  3. Connect the B-line and the P-line to the battery.
  4. Important: There are two B8 cables. Only the first B8 line needs to be connected. The second B8 cable does not need to be connected.
Wiring diagram for 16-string cells and 8-string cells, showing connections for total positive electrode, total negative electrode, heater element, temperature control switch, display/switch, inverter, charger, and equal load of motor.
Figure 8: Wiring Method for 16-string and 8-string Cells

Interface Board Connections: The interface board provides connections for LED indicators, reset switch, DIP switch, dry contacts, and communication ports (CAN, RS485). Refer to the diagram below for detailed pin definitions.

Detailed diagram of the interface board showing pinouts for RS485-1, RS485-2, RS232, CAN, UART, heat function port, display or switch port, and dial switch.
Figure 9: Interface Board Details
Diagram showing the dimensions of the interface board.
Figure 10: Interface Board Dimensions

6. Operating Instructions

6.1. Device Activation

Before powering on the protection board, double-check that the balance cables are properly connected and that the P- and B- lines are correctly connected. Ensure the protection board is securely fixed to the battery cells. Incorrect connections can lead to malfunctions or damage.

The protection board does not have a physical power-on switch. It is designed for charging activation mode. To activate, connect a charger with a voltage 2V higher than the battery voltage after the battery assembly is complete. The BMS will power on automatically.

Alternatively, the BMS can be activated via a connected display screen (if applicable) or by pressing a button on the interface board.

6.2. APP Installation and Parameter Setting

The JIKONG BMS supports a mobile APP for Android (version 7 minimum required) and iOS/HarmonyOS. Scan the QR code below to download the official APP.

QR code for JIKONG Mobile APP download.
Figure 11: Mobile APP Download QR Code

Once installed, connect the APP to the BMS via Bluetooth to view real-time battery status and adjust parameters. Key parameters to set include:

  • Battery type (LiFePo4, Li-ion, LTO)
  • Number of cells
  • Battery capacity
  • Balance trigger differential pressure (default value can be retained)
  • Voltage and current calibration
  • Protection thresholds (overcharge, undervoltage, overcurrent, over/under temperature)
Mobile APP interface showing protocol docking options and supported CAN protocols.
Figure 12: Mobile APP Interface for Protocol Docking
Image showing multi-screen display options including mobile app, PC software, and JIKONG home storage dedicated display.
Figure 13: Multi-screen Display Options

6.3. Active Equalization

When active equalization is enabled in the APP, the BMS automatically balances the cells when the voltage difference between any two strings exceeds the set threshold. The balancing stops when the difference falls below the threshold. The default balance current is 2A. Adjust the balance current based on your battery capacity, ensuring it does not exceed 0.2C of the battery capacity. If not needed, the balancing function can be turned off in the BMS control page.

Diagram illustrating efficient balance to prolong battery life, comparing ordinary home storage protection board with JIKONG home storage BMS balanced current.
Figure 14: Efficient Balance for Battery Life

6.4. Heating Function

The BMS includes a heating function to prevent battery activity reduction in low temperatures. It uses a resistance heater or heating film (not included) with a designed heating current of 4A. Users can switch this function on/off via the BMS control page in the APP. It is recommended to use a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary protection.

6.5. Dry Contact Function

Two dry contacts are provided to control external devices like alarms or cooling fans. When the BMS detects an over-temperature, overcharge, or over-discharge state, the dry contacts can trigger an alarm or activate a fan. Users can select two trigger conditions in the APP.

Wiring diagram for dry contact function, showing connection to a buzzer and DC power supply.
Figure 15: Dry Contact Wiring Diagram

6.6. Communication Function

The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate inverter protocol in the APP. Two RS485 interfaces are available: RS485-1 for communication with inverters and other settings, and RS485-2 for parallel connection of battery packs and communication with a host computer. The communication address can be set via DIP switches (0-15).

6.7. LED Indicators

The interface board features LED indicators to show the BMS working status and remaining battery power. The Bluetooth connection indicator (D1) is steady on when connected and blinks when disconnected. The power LED description is as follows:

Capacity (%) L5 L4 L3 L2 L1
0-20%OFFOFFOFFOFFON
20-40%OFFOFFOFFONON
40-60%OFFOFFONONON
60-80%OFFONONONON
80-100%ONONONONON

Note: ON indicates that the LED is on, OFF indicates that the LED is off.

7. Maintenance

  • Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
  • Software Updates: Keep the mobile APP and PC software updated to the latest versions to ensure optimal performance and access to new features.
  • Cleaning: Ensure the BMS board and interface board are kept clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Environmental Conditions: Operate the BMS within the specified temperature range (-30°C to 70°C) to prevent damage.

8. Troubleshooting

The JIKONG BMS is equipped with various protection features. If the system enters a protection state, identify the cause using the APP or display screen and take corrective action.

  • Overcharge Protection: If any cell voltage exceeds the set overcharge protection voltage, charging will stop. Charging resumes when all cell voltages drop below the recovery voltage. Check charger settings and battery health.
  • Undervoltage Protection: If any cell voltage drops below the set undervoltage protection voltage, discharge will stop. Discharge resumes when all cell voltages rise above the recovery voltage. Check battery capacity and load.
  • Overcurrent Protection (Charge/Discharge): If charging or discharging current exceeds the set limit for a specified delay, the respective operation will stop. It resumes after the overcurrent release time. Reduce load or charging current.
  • Overtemperature Protection: If the BMS or battery temperature exceeds the set limit, charging/discharging will stop. Operations resume when the temperature falls below the recovery threshold. Ensure adequate ventilation and consider using the heating function in cold environments.
  • Low Temperature Protection: If the battery temperature drops below the set limit during charging, charging will stop. It resumes when the temperature rises above the recovery threshold. Use the heating function in extremely cold areas.
  • Short Circuit Protection: If a short circuit is detected, the BMS will stop operation. After the short circuit recovery time, it will attempt to resume. Ensure all wiring is correct and there are no external short circuits. Increase short circuit delay in APP if false triggers occur due to high instantaneous currents from loads.
  • Emergency Switch: In case of critical issues (over-temperature, over-discharge, overcharge, string drop), activating the emergency switch in the APP will force charge/discharge for 30 minutes, providing emergency use time.
  • Intelligent Sleep: If the BMS enters intelligent sleep mode (charging/discharging current less than 1A for 26 consecutive hours), it can be reactivated by pressing a button or connecting a charger.

9. User Tips

  • Initial Setup: Always verify all connections and settings in the APP before initial power-on to prevent potential issues.
  • Monitoring: Regularly check battery status via the mobile APP or PC software to ensure optimal performance and detect any anomalies early.
  • Parameter Adjustment: When adjusting parameters, especially protection thresholds, always refer to the specific requirements of your battery cells and system.

10. Warranty and Support

For any technical support, warranty claims, or further inquiries, please contact JIKONG Official Store directly. Ensure you provide your product model (JK-PB2A16S20P) and any relevant details about your issue.

A detailed user manual in PDF format is available for download: User manual (PDF).


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.