SINOTIMER CN101S

SINOTIMER CN101S Digital LCD Programmable Timer Switch

User Manual

1. Introduction

The SINOTIMER CN101S is a versatile digital LCD programmable timer switch designed for precise control of electrical appliances. It offers daily and weekly programming with a minimum interval of 1 second, making it suitable for a wide range of applications from household automation to industrial control. This manual provides detailed instructions for the installation, operation, and programming of your CN101S timer switch.

2. Features

  • Easy-to-read LCD display with LED indicators.
  • Minimum 1-second interval for precise timing.
  • Up to 8 ON/OFF programs per day, with 15 combinations for weekly scheduling.
  • 24 hours / 7 days a week programmable functionality.
  • Countdown function with a maximum of 24 hours countdown to OFF.
  • Built-in rechargeable battery for memory backup during power failures (up to 60 days).
  • Manual ON/OFF/AUTO control.
  • Designed for panel or wall mounting.

3. Safety Information

⚠ WARNING: This product can expose you to chemicals including phthalates (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Always ensure proper electrical installation by a qualified professional if you are unsure. Disconnect power before installation or maintenance. Do not exceed the maximum load rating of the device.

4. Product Overview

Front view of SINOTIMER CN101S digital timer switch
Figure 4.1: Front view of the CN101S timer switch, showing the LCD display and control buttons.
Front view of SINOTIMER CN101S with included wire terminals
Figure 4.2: CN101S timer switch with included blue wire terminals.
Back view of SINOTIMER CN101S showing wiring terminals
Figure 4.3: Back view of the CN101S, detailing wiring terminals (1-5) and input/output specifications for a 200-250VAC model.

Control Buttons:

  • P (Program): Enters or exits programming mode.
  • D+ (Day): Adjusts the day of the week in time setting or programming mode.
  • H+ (Hour): Adjusts the hour in time setting or programming mode.
  • M+ (Minute): Adjusts the minute in time setting or programming mode.
  • Clock Icon: Used in combination with D+, H+, M+ to set the current time.
  • R (Reset): Resets the timer to factory defaults.
  • MANUAL: Toggles between ON, AUTO, and OFF modes.

5. Specifications

Parameter Value
Model Number CN101S
Power Supply Options 5V, 12V, 24V, 110V, 220V AC 50/60Hz (Verify your specific unit's voltage)
Max Load 16A
Minimum Interval 1 second
Timing Range 1 second to 168 hours
Setting Groups 8 ON/OFF per day
Programs 15 Groups
Black-out Memory 60 days (via built-in rechargeable battery)
Average Error Less than ± 2 sec/day
Battery Type 1.2V, internal, rechargeable (for memory backup)
Installation Panel/Wall Mounted
Material Plastic
Package Dimensions (L x W x H) 8 cm x 8 cm x 5 cm
Package Weight 0.091 kg

6. Installation

IMPORTANT: Disconnect all power before attempting any wiring. Incorrect wiring can cause damage to the device, property, or personal injury. If you are not comfortable with electrical wiring, please consult a qualified electrician.

The CN101S timer switch is designed for panel or wall mounting. Ensure the mounting location is dry, well-ventilated, and free from excessive heat or vibration.

Wiring Instructions (Example for 200-250VAC Model):

The wiring diagram below is an example for a 200-250VAC version of the CN101S. If your unit is a 12V, 24V, or 110V model, the wiring configuration will be different. Always refer to the specific wiring diagram printed on your unit or provided with your specific voltage model.

Wiring diagram for SINOTIMER CN101S 200-250VAC model
Figure 6.1: Wiring terminals for a 200-250VAC CN101S model. Labels: 1 (LINE), 2 (NEUT INPUT), 3 (NEUT LOAD), 4 (LOAD), 5 (LOAD).
  1. Terminal 1 (LINE): Connect the live (phase) wire of your power supply to this terminal.
  2. Terminal 2 (NEUT INPUT): Connect the neutral wire of your power supply to this terminal.
  3. Terminal 3 (NEUT LOAD): Connect the neutral wire of the appliance you wish to control to this terminal. This terminal is typically internally connected to Terminal 2 (Neutral Input).
  4. Terminal 4 (LOAD): Connect the live (phase) wire of the appliance you wish to control to this terminal. This is the switched live output.
  5. Terminal 5 (LOAD): This terminal is typically used for a second switched live output or for specific wiring configurations. Consult your specific unit's diagram if using. For a single load, Terminal 4 is usually sufficient.

Ensure all connections are secure and insulated. After wiring, mount the timer switch using the provided screw holes.

7. Initial Setup and Operation

7.1. Power On and Initial Charge:

Upon first power-up, the internal rechargeable battery may be low. Allow the unit to be powered for at least 15-30 minutes to charge the battery. The display may be blank or dim until sufficient charge is present.

7.2. Resetting the Timer:

Press the R (Reset) button using a pointed object (e.g., a pen tip). This will clear all settings and reset the timer to its default state (usually 0:00, Monday, OFF mode).

7.3. Setting Current Time and Day:

  1. Press and hold the Clock Icon button.
  2. While holding the Clock Icon button, press D+ to set the current day of the week.
  3. While holding the Clock Icon button, press H+ to set the current hour.
  4. While holding the Clock Icon button, press M+ to set the current minute.
  5. Release the Clock Icon button. The time and day are now set.

7.4. Manual Control:

Press the MANUAL button repeatedly to cycle through the operating modes:

  • ON: The output is continuously ON.
  • AUTO: The output operates according to the programmed ON/OFF times.
  • OFF: The output is continuously OFF.

For programmed operation, ensure the timer is set to AUTO mode.

8. Programming ON/OFF Times

The CN101S allows for up to 8 ON/OFF programs. Each program can be set for specific days of the week or combinations of days.

  1. Press the P (Program) button once. The display will show "1 ON" and the time will flash.
  2. Press D+ repeatedly to select the desired day(s) for this program. Options include individual days, weekdays, weekends, all days, or various combinations.
  3. Press H+ to set the desired hour for the first ON time.
  4. Press M+ to set the desired minute for the first ON time.
  5. Press P again. The display will show "1 OFF" and the time will flash.
  6. Repeat steps 2-4 to set the desired day(s), hour, and minute for the first OFF time.
  7. Continue pressing P to cycle through "2 ON", "2 OFF", up to "8 ON", "8 OFF", setting each program as needed. If you do not need all 8 programs, simply press P until you exit programming mode.
  8. After setting all desired programs, press the Clock Icon button to exit programming mode and return to the current time display.

Important: Ensure the timer is in AUTO mode for the programs to execute.

8.1. Countdown Function:

To use the countdown function (max 24 hours countdown to OFF):

  1. While in normal time display, press and hold the M+ button for a few seconds until "d ON" or "d OFF" appears.
  2. Use H+ and M+ to set the desired countdown duration (hours and minutes).
  3. Press M+ again to start the countdown. The display will show the remaining time.
  4. The output will switch OFF when the countdown reaches zero.

9. Maintenance

  • Keep the timer switch clean and dry. Avoid exposure to moisture, dust, and corrosive substances.
  • Do not attempt to open or repair the unit yourself. Refer to qualified service personnel.
  • The internal rechargeable battery is designed for long-term use and typically does not require replacement. If the display consistently goes blank or loses settings during power outages, the battery may need professional servicing.

10. Troubleshooting

Problem Possible Cause Solution
Display is blank or dim. No power supply; internal battery discharged. Check power connections. Allow unit to charge for 15-30 minutes.
Programs are not running. Timer is not in AUTO mode; incorrect program settings. Press MANUAL until "AUTO" is displayed. Review and correct program settings.
Appliance does not turn ON/OFF. Incorrect wiring; faulty appliance; timer malfunction. Verify wiring according to your unit's diagram. Test the appliance directly. If issues persist, contact support.
Time/settings are lost after power outage. Internal rechargeable battery is depleted or faulty. Ensure the unit is powered for an extended period to fully charge the battery. If problem persists, the battery may need servicing.

11. User Tips

No specific user tips are available from reviews or Q&A at this time. General tips for optimal use:

  • Before initial use, connect the timer to power for at least 30 minutes to ensure the internal battery is sufficiently charged for memory backup.
  • Always double-check your program settings, especially the days of the week, to avoid unintended operation.
  • If you only need a temporary ON/OFF, consider using the countdown function instead of setting a full program.

12. Warranty and Support

For warranty information, please refer to the terms and conditions provided by your retailer or the manufacturer at the time of purchase. If you encounter any issues not covered in this manual or require technical assistance, please contact the seller or manufacturer's customer support with your product model (CN101S) and purchase details.

Related Documents - CN101S

Preview SINOTIMER TM-630A/TM-630S Digital Timer: Features and Specifications
Detailed technical specifications and features for the SINOTIMER TM-630A and TM-630S digital programmable timers, including power supply, timing range, dimensions, and wiring.
Preview Sinotimer TM-616 Weekly Programmable Timer - Specifications and Operation
Detailed information on the Sinotimer TM-616 weekly programmable timer, including specifications, button functions, dimensions, wiring diagrams, and product lineup. Features 7-day programming and 30A switching capacity.
Preview SINOTIMER TM-610 Digital Time Switch for DIN Rail - User Manual and Specifications
Detailed specifications, wiring diagrams, and operating instructions for the SINOTIMER TM-610 digital time switch, designed for DIN rail mounting.
Preview SINOTIMER TM928 Series HD LCD Digital Timer Switch - User Manual and Specifications
Comprehensive guide to the SINOTIMER TM928 series digital timer switches, covering features, specifications, setup, and wiring for models like TM919, TM920, TM928, TM928S, TM928R, and TM929.
Preview SINOTIMER TM618s Digital Programmable Timer - User Manual and Specifications
Comprehensive guide to the SINOTIMER TM618s digital programmable timer, covering features, specifications, programming, wiring, and installation. Ideal for controlling electrical devices with daily ON/OFF schedules.
Preview Sinotimer TM-618 7-Day Electronic Timer Instruction Manual
Comprehensive instruction manual for the Sinotimer TM-618 7-Day Electronic Timer, detailing features, programming, manual operation, and safety warnings.