SUSWE SU600-2R2G1

Contents

SUSWE SU600-2R2G1 Variable Frequency Drive (VFD)

Instruction Manual

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the SUSWE SU600-2R2G1 Variable Frequency Drive. The SU600-2R2G1 is designed to convert single-phase 220V input to three-phase 380V output, providing adjustable speed control for 2.2KW (3HP) motors. Please read this manual thoroughly before using the product.

2. Safety Information

Always observe the following safety precautions to prevent personal injury or damage to the equipment:

  • Ensure the VFD is installed by qualified personnel only.
  • Disconnect all power before performing any wiring or maintenance.
  • Do not touch internal components immediately after power-off, as residual voltage may be present. Wait at least 5 minutes for capacitors to discharge.
  • Ensure proper grounding of the VFD and the motor.
  • Do not operate the VFD with damaged cables or if the casing is open.
  • Protect the VFD from moisture, dust, direct sunlight, and corrosive gases.

Warning: Residual voltage may remain for 5 minutes after power-off.

3. Package Contents

Verify that all items are present in the package:

  • SUSWE SU600-2R2G1 Variable Frequency Drive unit
  • External operation panel (optional, may be included)
  • Connecting cable for external operation panel (if applicable)
  • This instruction manual

4. Specifications

The following table details the specifications for the SU600-2R2G1 model:

SU600-2R2G1 Product Parameters
ParameterValue
Model NumberSU600-2R2G1
Adapted Motor Power2.2 KW (3 HP)
Input VoltageSingle-phase 220V
Output VoltageThree-phase 380V
Output Current5A
Output Frequency50-300Hz
Output Power Range1 - 200 KW (General series)
TypeDC/AC Inverter
Weight0.72 Kg (for SU600-2R2G1) / 1 KG (General)
Dimensions (LxWxH)147 x 72 x 118.4 mm
Output TypeSINGLE
CertificationCE, RoHS, FC

For detailed specifications of other SU600 series models, refer to the 'SU600 Series Naming Rules and Specifications Table' image below.

SU600 Series Naming Rules and Specifications Table
Figure 4.1: SU600 Series Naming Rules and Specifications Table. This table provides voltage grades, power grades, and detailed electrical specifications for various SU600 frequency converter modes, including power supply capacity, rated input/output current, and adapted motor power (kW/HP).
VFD Certifications (CE, RoHS, FC)
Figure 4.2: VFD Certifications. The product has undergone multiple certification tests, including CE, RoHS, and FC, ensuring quality and compliance.

5. Setup and Installation

Proper installation is crucial for the VFD's performance and safety. Follow these steps carefully:

5.1 Physical Installation

  • Mount the VFD in a clean, dry, and well-ventilated area, away from direct heat sources or excessive vibration.
  • Ensure sufficient clearance around the unit for proper heat dissipation.
  • The VFD can be mounted vertically.
SU600-2R2G1 VFD Product Parameters (White Model)
Figure 5.1: SU600-2R2G1 VFD (White Model) with dimensions 147x72x118.4mm. This image shows the physical appearance and size of the VFD unit.
SU600-2R2G1 VFD Product Parameters (Black Model)
Figure 5.2: SU600-2R2G1 VFD (Black Model) with dimensions 147x72x118.4mm. This image shows the physical appearance and size of the VFD unit in black.

5.2 Wiring Instructions

Before wiring, ensure the power supply is disconnected. Open the terminal cover to access the wiring points.

Accessing VFD Wiring Terminals
Figure 5.3: Opening the terminal cover to access the VFD's wiring connections.

Refer to the wiring diagrams below for correct connections:

  • Input Power Connection: Connect the single-phase 220V power supply to terminals R, S/L1, T/L2.
  • Output Power Connection: Connect the three-phase motor to terminals U, V, W.
  • Ground Wire: Ensure the VFD and motor are properly grounded.
  • Brake Resistor Connection: If using a brake resistor (e.g., for CNC machine tools), connect it to terminals P+ and PB.
Basic VFD Wiring Diagram
Figure 5.4: Basic VFD Wiring Diagram. This diagram illustrates the connections for input power (R S/L1 T/L2), output to motor (U V W), ground wire, and optional brake resistor (P+ PB).
Detailed SU600 Series Wiring Diagrams
Figure 5.5: Detailed SU600 Series Wiring Diagrams. This image provides specific wiring configurations (SU6001, SU6002, SU6003 types) for connecting the VFD to a motor and power source, including circuit breakers and ground connections.

5.3 External Operation Panel Connection

If using an external operation panel, connect it to the VFD using the provided cable. The external panel allows for remote control and monitoring.

Connecting the External Operation Panel
Figure 5.6: Connection of the external operation panel to the VFD unit via a blue cable.

6. Operating Instructions

The VFD can be operated via its integrated control panel or an external panel.

6.1 Panel Operation Demonstration

The video below demonstrates the basic operation of the SU600 inverter using the control panel to adjust motor speed.

Video 6.1: SU600 Inverter Panel Operation Demonstration. This video shows how to adjust the motor speed using the VFD's control panel.

6.2 Basic Operation Steps

  1. Power On: After ensuring all wiring is correct and secure, apply power to the VFD. The display should light up.
  2. Set Frequency: Use the 'PRG' (Program) button to enter parameter settings. Navigate to the frequency setting parameter (refer to the full product manual for specific parameter codes). Use the up/down arrows to adjust the desired output frequency.
  3. Start Motor: Press the 'RUN' button to start the motor. The motor will accelerate to the set frequency.
  4. Adjust Speed: During operation, you can typically adjust the frequency (and thus motor speed) using the up/down arrows on the panel.
  5. Stop Motor: Press the 'STOP/RST' button to stop the motor.
  6. Reverse Direction: If supported and configured, use the 'FWD/REV' button or corresponding parameter to change the motor's rotation direction.

6.3 Advanced Settings

The VFD offers various programmable parameters for fine-tuning performance, including acceleration/deceleration times, motor parameters, and control modes. Consult the comprehensive product manual for detailed parameter descriptions and programming instructions.

7. Maintenance

Regular maintenance ensures the longevity and reliable operation of your VFD.

  • Cleaning: Periodically clean the VFD's exterior and cooling fins to prevent dust buildup, which can impede heat dissipation. Use a soft, dry cloth. Do not use liquid cleaners.
  • Fan Inspection: Check the cooling fan for proper operation and ensure it is free from obstructions. Replace if noisy or not functioning.
  • Terminal Tightness: Annually, or as needed, check all wiring terminals for tightness. Loose connections can cause overheating and malfunction.
  • Environmental Check: Ensure the operating environment remains within specified temperature and humidity ranges.
  • Internal Inspection: Only qualified technicians should perform internal inspections. This involves checking for signs of overheating, damaged components, or loose connections.

8. Troubleshooting

This section provides solutions to common issues. For complex problems, contact technical support.

Common Troubleshooting Guide
ProblemPossible CauseSolution
VFD does not power onNo input power; Blown fuse; Internal faultCheck power supply; Check fuses; Contact support
Motor does not runIncorrect wiring; Parameter settings incorrect; Motor faultVerify wiring (refer to Section 5.2); Check motor parameters; Test motor independently
Overcurrent faultMotor overload; Short circuit in motor/cables; Rapid accelerationReduce load; Check motor/cables; Increase acceleration time parameter
Overvoltage faultHigh input voltage; Rapid deceleration; Regenerative loadCheck input voltage; Increase deceleration time parameter; Install brake resistor (if applicable)
Overheat faultPoor ventilation; Ambient temperature too high; Fan failure; Dust buildupImprove ventilation; Reduce ambient temperature; Clean VFD; Check fan operation

9. User Tips

  • Parameter Backup: Before making significant changes to parameters, record the original settings. This allows for easy restoration if needed.
  • Gradual Adjustments: When adjusting frequency or other operational parameters, make small, gradual changes to observe the motor's response and avoid sudden stresses.
  • Environmental Control: Maintaining a stable and clean environment for the VFD will significantly extend its lifespan and ensure consistent performance.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Ensure you have your product model number (SU600-2R2G1) and purchase details available when contacting support.

The manufacturer is committed to providing high-quality products and support. If you encounter any issues, please reach out for assistance.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.