KKmoon KKM828

Contents

KKmoon KKM828 Intelligent Graphical Digital Oscilloscope Multimeter User Manual

Model: KKM828

1. Introduction

The KKmoon KKM828 is a versatile 2-in-1 intelligent graphical digital oscilloscope multimeter designed for efficient electrical measurement and waveform analysis. This device combines the functionalities of a digital multimeter with a graphical oscilloscope, offering a color screen for clear display and adjustable parameters. It is built with fine quality materials, ensuring practicality and ease of use for a wide range of applications.

KKmoon KKM828 Oscilloscope Multimeter with color screen and adjustable parameters

Figure 1: Main product view with color screen and adjustable parameters.

2. Product Accessories

The KKM828 package includes the following items:

  • 1 x KKM828 Host (Graphical Multimeter)
  • 1 x Pair of Test Pens
  • 1 x Protective Bag
  • 1 x User Manual (this document)
  • 1 x Packing Box
KKmoon KKM828 product accessories including the device, test pens, protective bag, and manual

Figure 2: Product accessories included in the package.

3. Setup

3.1. Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Open the cover.
  3. Insert 3 AA batteries (not included) into the compartment, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

3.2. Connecting Test Pens

  1. Identify the red and black test pens.
  2. Insert the red test pen into the 'VΩCapA' (positive) input jack.
  3. Insert the black test pen into the 'COM' (common/negative) input jack.
  4. For high current measurements (up to 10A), insert the red test pen into the '10A' input jack. For mA/µA current measurements, use the 'mAmF' input jack.

4. Operating Instructions

4.1. Power On/Off

Rotate the central function dial from 'OFF' to any measurement mode to power on the device. Rotate it back to 'OFF' to power off.

4.2. Function Selection

Use the central function dial to select the desired measurement mode (e.g., Voltage, Current, Resistance, Capacitance, Frequency, Diode, Continuity). The device supports both automatic and manual ranging for multimeter measurements.

4.3. Multimeter Measurement Functions

The KKM828 offers a comprehensive set of multimeter functions:

  • AC/DC Voltage: Measure voltage in various ranges.
  • AC/DC Current: Measure current in mA, µA, or 10A ranges.
  • Resistance: Measure resistance from ohms to megaohms.
  • Capacitance: Measure capacitance from nanofarads to millifarads.
  • Frequency: Measure frequency in Hertz.
  • Duty Cycle: Measure the duty cycle of a signal.
  • Diode Test: Test diodes for functionality.
  • Continuity Test: Check for circuit continuity with an audible beep.
Examples of waveform display, AC voltage, resistance, and capacitance measurements on the KKM828

Figure 3: Examples of various measurement displays including waveform, AC voltage, resistance, and capacitance.

Examples of frequency, duty cycle, diode test, and continuity measurements on the KKM828

Figure 4: Examples of frequency, duty cycle, diode test, and continuity measurements.

4.4. Oscilloscope Mode

To enter oscilloscope mode, long press the 'R' key. This allows for direct waveform measurement without the need for a separate oscilloscope probe. The device provides a clear waveform display on its 240*320 color screen.

Instructions for switching between Multimeter and Oscilloscope modes, showing test leads connected

Figure 5: Long press 'R' key to enter oscilloscope mode.

4.5. Oscilloscope Parameter Adjustment

In oscilloscope mode, you can set parameters such as time base, range, and trigger level to fine-tune your waveform analysis. The secondary display provides additional information like VP-P, average value, effective value, frequency, time base, and amplitude.

Diagram showing adjustable oscilloscope parameters like trigger method, trigger mode, trigger level, time base, and range

Figure 6: Adjustable oscilloscope parameters for detailed waveform analysis.

4.6. Data and Waveform Storage

The KKM828 features mass storage capabilities, allowing you to save up to 100 data records and 10 waveforms. This enables easy comparison and analysis of historical and real-time data, which can be displayed on the same screen.

Illustration of data and waveform saving capabilities, showing multiple saved measurements

Figure 7: Data and waveform saving feature for analysis.

Illustration of the same screen display feature showing retained data and real-time data for comparison

Figure 8: Same screen display for comparing retained and real-time data.

4.7. Relative Value (REL) and Max/Min Functions

The device includes REL and Max/Min functions:

  • REL (Relative Value): Effectively eliminates the influence of lead resistance on measurement results, providing more accurate readings.
  • MAX/MIN: Records the maximum and minimum values during the measurement process, useful for monitoring signal fluctuations.
Illustration of Relative Value (REL) and Max/Min functions on the KKM828 display

Figure 9: Relative Value (REL) and Max/Min functions for enhanced measurement analysis.

5. Maintenance

5.1. Cleaning

To clean the device, use a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the casing or display. Ensure the device is powered off before cleaning.

5.2. Battery Replacement

When the battery indicator shows low power, replace the 3 AA batteries promptly to ensure accurate measurements and continuous operation. Follow the battery installation steps in Section 3.1.

5.3. Fuse Replacement

The device is equipped with double insurance tubes: 500mA/250V and 10A/250V. If a fuse blows, replace it with a fuse of the exact same specifications to prevent damage to the device and ensure safety. Refer to the device's internal diagram or contact support for fuse location and replacement procedures if unsure.

5.4. Storage

Store the KKM828 in a dry environment with temperatures between -10℃ and 60℃ and relative humidity less than 90%RH. Remove batteries if storing for extended periods to prevent leakage.

6. Troubleshooting

  • Device does not power on: Check battery installation and ensure batteries are not depleted.
  • Beep warning (Input voltage > 24V): The device will emit a beep warning if the input voltage exceeds 24V. This is a safety feature. Reduce the input voltage to within safe operating limits.
  • Beep warning (Input over range): If the input signal exceeds the selected measurement range, the device will beep. Adjust the range setting or ensure the input is within the device's capabilities.
  • Continuity test does not beep: Ensure the resistance is below 50Ω for the beep to activate. Check test leads for proper connection and integrity.
  • Inaccurate readings: Ensure test leads are properly connected and not damaged. Use the REL function to compensate for lead resistance if necessary. Check battery level.

7. Specifications

Detailed product parameters and dimensions, including a table of specifications for the KKM828

Figure 10: Product dimensions and key parameters.

FeatureSpecification
MaterialABS
ColorBlack
Display320*240 LCM, about 2.4 inches, white backlit
Input Resistance10MΩ
Battery3 * AA battery (not included)
Power ConsumptionAbout 80mA
Use Time (low light)About 5 hours
Storage100 data / 10 waveforms
Use Environment0~40℃, <75%RH
Storage Environment-10~60℃, <90%RH
BandwidthACV/1MHz, ACA/5KHz
Max. Real-time Sampling Rate2.5Msps
Multimeter MeasurementAutomatic range + manual range
Oscilloscope Secondary DisplayVP-P, average value, effective value, frequency, time base, amplitude
Measurement ModeNormal, Automatic
Item Size160 * 83 * 32mm (6.3 * 3.3 * 1.3in)
Item Weight195g (6.9ounce)
DC Voltage Range400mV/4V/40V/400V/1000V
DC Voltage Uncertainty0.75% rdg+10dgt
AC Voltage Range400mV/4V/40V/400V/750V
AC Voltage Uncertainty1.0% rdg+10dgt
DC Current Range40mA/400mA/4A/10A
DC Current Uncertainty1.2% rdg+10dgt
AC Current Range40mA/400mA/4A/10A
AC Current Uncertainty1.5% rdg+10dgt
Resistance Range400.0Ω~40.00MΩ
Resistance Uncertainty1.0% rdg+5dgt
Capacitance Range0.1nF~100, 10.00mF
Capacitance Uncertainty2.0% rdg+10dgt
Frequency Range5Hz~10MHz
Frequency Uncertainty1.0% rdg+5dgt
Duty Cycle Range0.1%~99.9%
Duty Cycle Uncertainty1.0% rdg+5dgt
Diode TestVoltage about 5V, test current about 1.5mA
Continuity TestJudgment resistance about: <50Ω beep
Fuse Specifications500mA/250V, 10A/250V
CertificationCE

8. User Tips

  • Quick Oscilloscope Access: For immediate waveform viewing, simply long-press the 'R' button to switch to oscilloscope mode without needing to navigate through menus.
  • Stable Viewing: Utilize the integrated back bracket, which tilts at 60°, for comfortable and stable viewing during measurements.
  • Accurate Resistance: When performing resistance measurements, use the 'REL' function to nullify the resistance of your test leads, ensuring more precise results.
  • Monitoring Fluctuations: Employ the 'MAX/MIN' function to capture the highest and lowest values during a measurement session, which is ideal for observing signal variations over time.
  • Data Comparison: Take advantage of the 'Same Screen Display' feature to view historical data alongside real-time measurements, facilitating quick comparisons and analysis.
  • Safety First: Always heed the beep warnings for input voltage exceeding 24V or over-range conditions to prevent damage to the device and ensure personal safety.

9. Warranty and Support

9.1. Warranty

All items come with a 1-year guarantee. If your purchase does not meet merchantable quality, fitness for purpose, or match the description, please contact the seller for resolution.

9.2. Technical Support

For any technical inquiries, operational difficulties not covered in this manual, or warranty claims, please contact the manufacturer or your point of purchase for assistance.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.