1. Introduction
The JIKONG Smart Active Battery Management System (BMS) is an intelligent protection board designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote monitoring. This BMS is compatible with various battery chemistries, including lithium iron phosphate (LiFePo4), ternary lithium, and lithium titanate (LTO) batteries.
The core of this protection board is its energy transfer active balancing technology, which ensures a maximum continuous balance current of 0.6A. This high-current active equalization significantly improves battery consistency, extends battery range, and delays battery aging. The compact design, ease of operation, and comprehensive functionality make it suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Packing List
Please check the package contents upon receipt:
- BMS Unit x 1
- NTC Temperature Sensor x 1 (40cm long)
- Sampling Line B x 1 (70cm long)
- Sampling Line A x 1 (70cm long)
- Switch Key x 1

3. Specifications
The JIKONG Smart Active BMS is available in various configurations. Below are the general product specifications and basic parameters for the 150A model. For detailed specifications of other current ratings (100A, 120A, 200A), please refer to the full PDF manual.

3.1. General Parameters (150A Protection Board)
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 24 | Strings |
| Maximum Balancing Current | 0.6 | A |
| Maximum Charging Current | 150 | A |
| Maximum Discharge Current | 150 | A |
| Maximum Instantaneous Current | 300 | A |
| Maximum Internal Loop Resistance | 0.39 | mΩ |
| Protective Plate Size | 162*102*20.4 | mm |
| Finished Weight | 567 | g |
3.2. Product Dimensions
The dimensions of the JK-BD6AXXS series protection board are 162mm x 102mm x 20.4mm. Data tolerance range is ±2mm.

4. Installation and Wiring
The JK-BD6AXXS-10P/12P/15P/20P series protection boards are suitable for lithium battery packs with 7-24 series cells. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure all cables are properly connected before powering on the BMS.
4.1. General Wiring Steps
- Connect all balance cables to the BMS.
- Insert the main power cables (B-line and P-line) into the BMS.
- Connect the B-line and P-line to the battery pack.
4.2. Wiring Diagram for 16-String Cells

4.3. Wiring Diagram for 24-String Cells

4.4. Interface Definitions
The BMS features a rich interface to meet various needs, including RS485/CAN communication, Bluetooth, NTC temperature sensing, soft switch, SOC indicator, key switch, and active equalizer.

P1 (XH-15AW) - Balance and Acquisition Interface:
- B-: Total negative battery terminal.
- B1-B14: Positive terminals for cells 1 through 14.
P2 (XH-11AW) - Balance and Acquisition Interface:
- B15-B24: Positive terminals for cells 15 through 24.
P3 (XH-4AW) - Temperature Interface:
- TIA, T1B: Pins for the first temperature sensor.
- T2A, T2B: Pins for the second temperature sensor.
P4 (A1254WF-4A) - Communication Interface:
- RS485 B, RS485 A: Negative and positive terminals for RS485 signal.
- CAN H, CAN L: Positive and negative terminals for CAN signal.
P5 (1.25T-4PWT) - GPS Interface:
- VGPS: Power output (voltage close to B+).
- TX, RX: UART_TX, UART_RX (3.3V).
- GND: Power/signal ground.
P6 (A1254WF-6A) - Display Interface:
- VCC: Display power output.
P7 (A1254WF-3A) - Parallel Interface:
- GND: Signal ground.
- P-EN: Parallel module enable signal (output low level to turn on parallel module).
- P-status: Parallel module status signal.
P8 (A1254WF-2A) - Alarm Interface:
- VCC: Alarm power supply positive.
- GND: Alarm power negative.
P9 (A1254WF-5A) - ACC Interface (Optional):
- ACC+, ACC-: ACC positive and negative.
- NC: Not connected.
- C_Detect+, C_Detect-: Charger output 12V positive and negative.
D1 - Heating Wire (16AWG-Orange-15CM, Optional):
- HT-: Heater element negative electrode.
Bluetooth Connection Indicator: When Bluetooth is connected, the indicator is steady on; when disconnected, it blinks.
P- Terminal: Connect to external load or negative terminal of charger.
B- Terminal: Connect to the negative battery terminal.
5. Operation
5.1. Device Activation
Before powering on the protection board, double-check that the balance cables are correctly connected and that the P- and B- terminals are securely attached to the battery. Ensure the protection board is firmly fixed to the battery pack. Incorrect connections can lead to malfunctions or damage.
The BMS does not have a physical power-on switch. It is designed for charging activation: the charger voltage must be 2V higher than the battery voltage. Once the battery assembly is complete, connect the charger to activate the protection board.
For users with an optional display screen or button, activation can also be achieved by simply plugging the cable into the display interface and pressing the button.
5.2. APP Installation and Parameter Setting
The JIKONG BMS features a mobile application compatible with Android and iOS operating systems. The APP allows you to monitor battery status, modify working parameters, and control charge/discharge switches.
To download the APP, scan the QR code below. An Android device with Android Version 7 or higher is required.

Once installed, use the APP to set parameters such as battery type, number of cells, battery capacity, and voltage/current calibration. For detailed instructions on parameter settings, please refer to the 'Instructions for Setting Protection Board Parameters' document (available in the full PDF manual).
5.3. Active Balancing
The active balancing function transfers energy from higher-voltage cells to lower-voltage cells to maintain battery consistency. You can set the balance trigger voltage difference (mV) via the APP. Balancing automatically starts when the voltage difference between any two cells exceeds the set value and stops when it falls within the range. The default balance current is 0.6A, adjustable based on battery capacity (recommended not to exceed 0.2C of battery capacity). If not needed, the balancing switch can be turned off in the APP.

5.4. Heating Function (Optional)
The optional heating function uses a resistance heater or heating film to warm the battery in low-temperature environments, preventing charging/discharging failures due to reduced battery activity. The designed heating current is 10A. This function can be toggled via the APP's BMS control page based on ambient temperature. It is recommended to install a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary safety measure to prevent thermal runaway.
5.5. Battery Parallel Function (Optional)
For energy storage applications, the BMS supports an optional battery parallel function. This requires a parallel module and disabling the 'charging current limiting' function in the APP.
5.6. ACC Detection Function (Optional)
The optional ACC detection function enables discharge. This can be achieved by applying a voltage (12V-70V) between ACC+ and ACC- or by short-circuiting them. Additionally, the charger detection function (C_detect+ and C_detect-) is reserved for enabling charging when a 12V signal is detected from the charger.
6. Protection Features
The JIKONG BMS provides comprehensive protection for your battery pack:
6.1. Overcharge Protection and Recovery
The BMS includes standard overcharge protection. Users can set the single cell overcharge protection voltage and recovery voltage in the APP. If any cell exceeds the set overcharge voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the recovery voltage, preventing cell damage from overcharging.
6.2. Discharge Undervoltage Protection and Recovery
Standard undervoltage protection is provided. Users can set the undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell drops below the undervoltage protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will automatically shut down to protect the battery.
6.3. Overcurrent Protection and Recovery (Charge & Discharge)
The BMS features standard overcurrent protection for both charging and discharging. Users can set continuous charge/discharge current, overcurrent delay, and overcurrent release time in the APP. If the current exceeds the set continuous current for the specified delay, the BMS will stop the operation. It will resume after the overcurrent release time. Note: The maximum continuous discharge current should not exceed the nominal current (100A/120A/150A/200A).
6.4. Overtemperature Protection and Recovery
Standard overtemperature protection for charging and discharging is included. Users can set the overtemperature protection and recovery thresholds in the APP. If the temperature exceeds the set value, the BMS will stop the respective operation (charging or discharging). Operation resumes when the temperature falls below the recovery threshold.
6.5. Low Temperature Protection and Recovery (Charging)
The BMS has standard low-temperature charging protection. Users can set the low-temperature charging protection and recovery thresholds in the APP. If the temperature falls below the set value, the BMS will stop charging. Charging resumes when the temperature rises above the recovery threshold. For very cold regions, using the optional heating function is recommended.
6.6. Short Circuit Protection and Recovery
Standard short circuit protection is provided. Users can set the short circuit protection delay (µs) and recovery time (s) in the APP. If a short circuit is detected, the BMS will trigger protection. Adjusting the delay can help prevent false triggers from high instantaneous currents during charger startup or load connection.
6.7. Emergency Switch
The emergency switch function allows the BMS to temporarily override protection (e.g., over-temperature, over-discharge) for 30 minutes, enabling emergency use. This can be activated via the APP's BMS control page.
6.8. Intelligent Sleep
The intelligent sleep function helps reduce the BMS's self-consumption. If the BMS is in standby (charge/discharge current less than 1A for 26 consecutive hours), it will enter sleep mode. It can be reactivated by pressing a button or connecting a charger.
7. Communication
The BMS supports optional CAN and RS485 communication functions. Users can select these based on their requirements. The APP's BMS control page allows switching between CAN and RS485 for multiplexed ports. For specific communication protocols and address settings, refer to the Jikong Protection Board communication protocol document.
8. Maintenance
To ensure optimal performance and longevity of your JIKONG BMS, regular checks are recommended:
- Visual Inspection: Periodically inspect all wiring and connections for any signs of wear, corrosion, or damage.
- Software Updates: Keep the mobile APP updated to the latest version to benefit from new features and bug fixes.
- Parameter Review: Occasionally review the BMS parameters in the APP to ensure they are still appropriate for your battery and usage patterns.
- Cleanliness: Keep the BMS unit clean and free from dust and debris to ensure proper heat dissipation.
9. Troubleshooting
If you encounter issues with your JIKONG BMS, consider the following:
- BMS Not Powering On: Verify all balance cables are correctly connected, and the main P- and B- terminals are securely attached to the battery. Ensure the battery charger is connected and providing a voltage at least 2V higher than the battery pack voltage for activation.
- Protection Triggered (Overvoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit): Check the corresponding parameters in the mobile APP. Ensure they are set appropriately for your battery type and usage. Inspect wiring for any faults or short circuits.
- Balancing Issues: Confirm that active balancing is enabled in the APP and that the balance trigger voltage difference is set correctly.
- Communication Problems: Ensure Bluetooth is enabled on your mobile device and the APP is connected. If using RS485/CAN, verify the correct port selection and communication protocol settings.
10. User Tips
- Wiring Diagrams are Crucial: Always refer to the specific wiring diagrams for your battery cell count (e.g., 16S or 24S) to ensure correct installation. Incorrect wiring is a common cause of issues.
- APP for Fine-Tuning: The mobile APP is powerful for customizing protection parameters. Take time to understand and adjust settings like overcharge/discharge voltages and current limits to match your battery's specifications and your application's needs.
- Consider Heating in Cold Climates: If operating in low temperatures, the optional heating function can significantly improve battery performance and lifespan.
11. Warranty and Support
For detailed warranty information, technical support, or further inquiries, please contact JIKONG Official Store. Refer to the complete 'Lithium battery active balance protection board maintenance manual' PDF for comprehensive guides and troubleshooting steps.
Manufacturer: Chengdu Jikong Technology Co.LTD