1. Introduction
The GEYA SUL180N Mechanical Timer Switch is designed to control any electrical installation through daily programs. This manual provides essential information for safe installation, operation, maintenance, and troubleshooting of your timer switch.

2. Important Safety Warnings
⚠ Caution: Electrical devices must be installed and assembled by a qualified and authorized installer. All electrical connections must comply with appropriate safety standards. Ensure the product is used with a 16A circuit breaker upstream.
- Install the timer in switchboard cabinets made of 35 mm symmetric sections, in accordance with EN 50022.
- The timer is internally protected against interference by a safety device. However, strong electromagnetic fields may affect its operation.
- To avoid interference, do not install the device near inductive loads (motors, transformers, contactors, etc.).
- A separate power line is recommended, equipped with a network filter if necessary.
- Inductive loads should be equipped with interference suppressors (varistor, RC filter).
- If used with other devices, verify that no parasitic disturbances will be caused.
3. Installation
The GEYA SUL180N is designed for DIN rail mounting. Follow the diagrams and instructions below for proper installation.
3.1 Dimensions

3.2 Wiring Connection
Ensure all wiring is performed by a qualified electrician following local electrical codes.


When the timer is used for a load exceeding its rated capacity, it is essential to combine the timer with one or more magnetic contactors, selected according to the specific load requirements.
4. Operation
4.1 Setting Daily Programs
To set the daily program, move the pins on the programming dial.
- Move pins to the right (Off) for periods when the connected device should be off.
- Move pins to the left (On) for periods when the connected device should be on.
The contact 1-2 will close during the "On" times.

4.2 Hour Update
Turn the main dial until the index points to the current time.
4.3 Manual Mode
The timer features a manual operating switch with two positions:
- ○ (Automatic functioning): The timer operates according to the set daily program.
- I (Permanent connection): The connected device remains continuously on, overriding the daily program.

5. Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | SUL180N |
| Theory | Mechanical |
| Type | Mini |
| Use | Timer Switch |
| Product Name | SUL180N 24hour Programm Timer Switch Mechanical |
| Function | Time Control Switch, Automatic Cycle |
| Ampere | 16A |
| Rated Working Voltage | 85V~250VAC |
| Rated Frequency | 45~60Hz |
| Drive | Quartz-controlled stepper motor |
| Power Reserve | 100 hours |
| Type of Dial | Daily: 96 pins |
| Minimum Setting Unit | 15 Minutes |
| Functioning Temperature | -10°C to +50°C |
| Protection Category | IP 20 as per IEC/EN 60529 |
| Protection Class | II as per IEC/EN60335 under Correct assembling conditions |
| Installation | Din Rail |
| Battery Included | Yes |
5.1 Certifications
GEYA products are certified to required industry standards, including CE, CB, SAA, SEMKO, TUV, and Rosh.

6. User Tips
- Initial Charge: Before first use, charge the timer for at least 2 hours to ensure normal operation, especially if it has been stored for a while.
- Professional Installation: Always have the timer installed by a qualified electrician to ensure safety and compliance with electrical standards.
- Circuit Protection: It is recommended to use the timer in conjunction with a 16A circuit breaker upstream for added protection.
- Load Management: If connecting loads that exceed the timer's rated capacity, ensure to use appropriate magnetic contactors to handle the excess load.
- Quality Assurance: GEYA products are generally regarded for good quality and value.
7. Maintenance
The SUL180N timer switch contains a non-removable battery for power reserve. This battery must not be disposed of as urban waste. Please ensure proper recycling to protect the environment. No other user-serviceable parts are inside.
8. Troubleshooting
- Timer Not Functioning: If the timer does not work normally upon initial setup or after a long period of inactivity, ensure it has been charged for at least 2 hours.
- Unexpected Operation: If the timer's operation is erratic or not as programmed, check for strong electromagnetic fields nearby. Relocate the timer or the inductive loads if possible. Ensure inductive loads are equipped with interference suppressors.
- Interference with Other Devices: If the timer causes or experiences parasitic disturbances when combined with other devices, verify the compatibility and proper installation of all components in the electrical group.
9. Warranty and Support
For warranty claims, technical support, or further assistance, please contact your retailer or the manufacturer directly. Refer to the product packaging or official GEYA website for contact information.
10. Environmental Disposal
This product contains a non-removable battery and should not be disposed of with general household waste. Please follow local regulations for the recycling of electronic products and batteries to protect the environment.

11. GEYA Company Overview
Watch this video for an overview of GEYA's manufacturing process and commitment to quality.
12. Additional Resources
A detailed user manual in PDF format is also available for download. You can find it at the following link: GEYA SUL180N User Manual (PDF).